Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Manual MeansSpec. No.:- Bd.A.1 Page Number 259 |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m) By Manual MeansSpec. No.:- Bd.A.1 Page No.259 |
| 3 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 4 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 5 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 6 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 7 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 8 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 9 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 10 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 11 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with allleads, lifts etc.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 12 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with allleads, lifts etc.Spec. No.:- As directed by Engineer in charge.First Floor |
| 13 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with allleads, lifts etc.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 14 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with allleads, lifts etc.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 15 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge.Ground Floor |
| 16 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge.First Floor |
| 17 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge.Second Floor |
| 18 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge.Third Floor |
| 19 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc completeSpec. No.:- As directed by Engineer in charge.Ground Floor |
| 20 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc completeSpec. No.:- As directed by Engineer in charge.First Floor |
| 21 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc completeSpec. No.:- As directed by Engineer in charge.Second Floor |
| 22 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc completeSpec. No.:- As directed by Engineer in charge.Third Floor |
| 23 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 24 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 25 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 26 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 27 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 28 | Transportation of excavated & debris from site to disposing site inluding loading , unloading & tranportation etc. complete. (lead 3km) |
| 29 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Spec. No.:- As directed by engineer in chargeGround Floor |
| 30 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Spec. No.:- As directed by engineer in chargeFirst Floor |
| 31 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Spec. No.:- As directed by engineer in chargeSecond Floor |
| 32 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Spec. No.:- As directed by engineer in chargeThird Floor |
| 33 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd.L.1 Page Number 367Ground Floor |
| 34 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd.L.1 Page Number 367First Floor |
| 35 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd.L.1 Page Number 367Second Floor |
| 36 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd.L.1 Page Number 367Third Floor |
| 37 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368Ground Floor |
| 38 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368First Floor |
| 39 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368Second Floor |
| 40 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368Third Floor |
| 41 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.10, Page Number370Ground Floor |
| 42 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.10, Page Number370First Floor |
| 43 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.10, Page Number370Second Floor |
| 44 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.10, Page Number370Third Floor |
| 45 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369Ground Floor |
| 46 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369First Floor |
| 47 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369Second Floor |
| 48 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369Third Floor |
| 49 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.Spec. No.:- Bd.M.3 Page Number 380 |
| 50 | Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.Spec. No.:- As directed by Engineer in Charge |
| 51 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622- 2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec.No.:- Bd.M. 12 Page No.385Ground Floor |
| 52 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622- 2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec.No.:- Bd.M. 12 Page No.385First Floor |
| 53 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622- 2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec.No.:- Bd.M. 12 Page No.385Second Floor |
| 54 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622- 2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec.No.:- Bd.M. 12 Page No.385Third Floor |
| 55 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting /dado, Spec.No.:- Bd.M. 12 Page No.385Ground Floor |
| 56 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting /dado, Spec.No.:- Bd.M. 12 Page No.385First Floor |
| 57 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting /dado, Spec.No.:- Bd.M. 12 Page No.385Second Floor |
| 58 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting /dado, Spec.No.:- Bd.M. 12 Page No.385Third Floor |
| 59 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring Spec.No.:- Bd.M.12 Page No. 385Ground Floor |
| 60 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring Spec.No.:- Bd.M.12 Page No. 385First Floor |
| 61 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring Spec.No.:- Bd.M.12 Page No. 385Second Floor |
| 62 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring Spec.No.:- Bd.M.12 Page No. 385Third Floor |
| 63 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting /dado, Spec.No.:- Bd.M.12 Page No. 385Ground Floor |
| 64 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting /dado, Spec.No.:- Bd.M.12 Page No. 385First Floor |
| 65 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting /dado, Spec.No.:- Bd.M.12 Page No. 385Second Floor |
| 66 | Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting /dado, Spec.No.:- Bd.M.12 Page No. 385Third Floor |
| 67 | Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Spec.No.:- Bd.M.13 Page No. 386.Ground Floor |
| 68 | Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Spec.No.:- Bd.M.13 Page No. 386.First Floor |
| 69 | Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Spec.No.:- Bd.M.13 Page No. 386.Second Floor |
| 70 | Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Spec.No.:- Bd.M.13 Page No. 386.Third Floor |
| 71 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec.No.:- Bd.M. 3 B/Page No. 380Ground Floor |
| 72 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec.No.:- Bd.M. 3 B/Page No. 380First Floor |
| 73 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec.No.:- Bd.M. 3 B/Page No. 380Second Floor |
| 74 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec.No.:- Bd.M. 3 B/Page No. 380Third Floor |
| 75 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec.No.:- As directed by Engineer-In- ChargeGround Floor |
| 76 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec.No.:- As directed by Engineer-In- ChargeFirst Floor |
| 77 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec.No.:- As directed by Engineer-In- ChargeSecond Floor |
| 78 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec.No.:- As directed by Engineer-In- ChargeThird Floor |
| 79 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec.No.:- Bd. M.22 B/Page No. 390Ground Floor |
| 80 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec.No.:- Bd. M.22 B/Page No. 390First Floor |
| 81 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec.No.:- Bd. M.22 B/Page No. 390Second Floor |
| 82 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec.No.:- Bd. M.22 B/Page No. 390Third Floor |
| 83 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec.No.:- As directed by Engineer in charge.Second Floor |
| 84 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec.No.:- As directed by Engineer in charge.Third Floor |
| 85 | Providing water proofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with water proofing compound @1 kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with water proofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with water proofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete .Spec. No.: As directed by Engineer-in-chargeGround Floor |
| 86 | Providing water proofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with water proofing compound @1 kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with water proofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with water proofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete .Spec. No.: As directed by Engineer-in-chargeFirst Floor |
| 87 | Providing water proofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with water proofing compound @1 kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with water proofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with water proofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete .Spec. No.: As directed by Engineer-in-chargeSecond Floor |
| 88 | Providing water proofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with water proofing compound @1 kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with water proofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with water proofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete .Spec. No.: As directed by Engineer-in-chargeThird Floor |
| 89 | Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 90 | Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge.First Floor |
| 91 | Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge.Second Floor |
| 92 | Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge.Third Floor |
| 93 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec.No.:- As directed by Engineer in charge.Ground Floor |
| 94 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec.No.:- As directed by Engineer in charge.First Floor |
| 95 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec.No.:- As directed by Engineer in charge.Second Floor |
| 96 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec.No.:- As directed by Engineer in charge.Third Floor |
| 97 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminet WP on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeGround Floor |
| 98 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminet WP on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeFirst Floor |
| 99 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminet WP on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeSecond Floor |
| 100 | Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminet WP on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeThird Floor |
| 101 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 1966 (Revised) including approved face laminet WP on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeGround Floor |
| 102 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 1966 (Revised) including approved face laminet WP on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeFirst Floor |
| 103 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 1966 (Revised) including approved face laminet WP on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeSecond Floor |
| 104 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 1966 (Revised) including approved face laminet WP on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-chargeThird Floor |
| 105 | Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcSpec. No.:- As directed by Engineer in charge.Ground Floor |
| 106 | Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcSpec. No.:- As directed by Engineer in charge.Second Floor |
| 107 | Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcSpec. No.:- As directed by Engineer in charge.Third Floor |
| 108 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with boxSpec. No.:- As directed by Engineer in charge.Ground Floor |
| 109 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with boxSpec. No.:- As directed by Engineer in charge.First Floor |
| 110 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with boxSpec. No.:- As directed by Engineer in charge.Second Floor |
| 111 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with boxSpec. No.:- As directed by Engineer in charge.Third Floor |
| 112 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.c. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.Ground Floor |
| 113 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.c. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.First Floor |
| 114 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.c. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.Second Floor |
| 115 | Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.c. 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.Third Floor |
| 116 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm.Ground Floor |
| 117 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm.First Floor |
| 118 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm.Second Floor |
| 119 | Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm.Third Floor |
| 120 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Ground Floor |
| 121 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.First Floor |
| 122 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Second Floor |
| 123 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.Third Floor |
| 124 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor (Complete Rate) |
| 125 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor (Part Rate - Labour Rate) |
| 126 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor (Complete Rate) |
| 127 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor (Part Rate - Labour Rate) |
| 128 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor (Complete Rate) |
| 129 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor (Part Rate - Labour Rate) |
| 130 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor (Complete Rate) |
| 131 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systeMS Hostel B with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor (Part Rate - Labour Rate) |
| 132 | Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.Ground Floor |
| 133 | Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.First Floor |
| 134 | Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.Second Floor |
| 135 | Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.Third Floor |
| 136 | Providing and applying two coat of pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 137 | Providing and applying two coat of pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 138 | Providing and applying two coat of pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 139 | Providing and applying two coat of pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 140 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.Spec. No.:- As directed by Engineer in charge. |
| 141 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Spec. No.:- Bd.U.1 Page Number 537Ground Floor |
| 142 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Spec. No.:- Bd.U.1 Page Number 537First Floor |
| 143 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Spec. No.:- Bd.U.1 Page Number 537Second Floor |
| 144 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.Spec. No.:- Bd.U.1 Page Number 537Third Floor |
| 145 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)Spec. No.:- As directed by Engineer InchargeGround Floor |
| 146 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)Spec. No.:- As directed by Engineer InchargeFirst Floor |
| 147 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)Spec. No.:- As directed by Engineer InchargeSecond Floor |
| 148 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)Spec. No.:- As directed by Engineer InchargeThird Floor |
| 149 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size __ m x 0.60 m and height is 0.75 m)Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 150 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size __ m x 0.60 m and height is 0.75 m)Spec. No.:- As directed by Engineer in charge.First Floor |
| 151 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size __ m x 0.60 m and height is 0.75 m)Spec. No.:- As directed by Engineer in charge.Second Floor |
| 152 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.Spec. No.:- As directed by Engineer in chargeGround Floor |
| 153 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.Spec. No.:- As directed by Engineer in chargeFirst Floor |
| 154 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.Spec. No.:- As directed by Engineer in chargeSecond Floor |
| 155 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.Spec. No.:- As directed by Engineer in chargeThird Floor |
| 156 | Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete.\\"Spec. No.:- As directed by Engineer in chargeGround Floor |
| 157 | Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete.\\"Spec. No.:- As directed by Engineer in chargeFirst Floor |
| 158 | Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete.\\"Spec. No.:- As directed by Engineer in chargeSecond Floor |
| 159 | Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete.\\"Spec. No.:- As directed by Engineer in chargeThird Floor |
| 160 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeGround Floor |
| 161 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeFirst Floor |
| 162 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeSecond Floor |
| 163 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeThird Floor |
| 164 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeGround Floor |
| 165 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeFirst Floor |
| 166 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeSecond Floor |
| 167 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeThird Floor |
| 168 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeGround Floor |
| 169 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeFirst Floor |
| 170 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeSecond Floor |
| 171 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeThird Floor |
| 172 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeGround Floor |
| 173 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeFirst Floor |
| 174 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeSecond Floor |
| 175 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeThird Floor |
| 176 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeGround Floor |
| 177 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeFirst Floor |
| 178 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeSecond Floor |
| 179 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in chargeThird Floor |
| 180 | Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551Ground Floor |
| 181 | Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551First Floor |
| 182 | Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551Second Floor |
| 183 | Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551Third Floor |
| 184 | Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551Ground Floor |
| 185 | Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551First Floor |
| 186 | Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551Second Floor |
| 187 | Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551Third Floor |
| 188 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. / soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. completeSpec. No.:- As directed by Engineer in charge.Ground Floor |
| 189 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. / soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. completeSpec. No.:- As directed by Engineer in charge.First Floor |
| 190 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. / soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. completeSpec. No.:- As directed by Engineer in charge.Second Floor |
| 191 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. / soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. completeSpec. No.:- As directed by Engineer in charge.Third Floor |
| 192 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C./ soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec.No.:- As directed by Engineer in charge.Ground Floor |
| 193 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C./ soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec.No.:- As directed by Engineer in charge.First Floor |
| 194 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C./ soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec.No.:- As directed by Engineer in charge.Second Floor |
| 195 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C./ soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec.No.:- As directed by Engineer in charge.Third Floor |
| 196 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Spec. No.:- As directed by Engineer InchargeGround Floor |
| 197 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Spec. No.:- As directed by Engineer InchargeFirst Floor |
| 198 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Spec. No.:- As directed by Engineer InchargeSecond Floor |
| 199 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.Spec. No.:- As directed by Engineer InchargeThird Floor |
| 200 | Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litresSpec. No.:- As directed by engineer-in- charge.Second Floor |
| 201 | Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litresSpec. No.:- As directed by engineer-in- charge.Third Floor |
| 202 | Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.Spec. No.:- As directed by Engineer in charge. Second Floor |
| 203 | Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.Spec. No.:- As directed by Engineer in charge. Third Floor |
| 204 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Spec.No.:- Bd.V.9 Page No. 555Second Floor |
| 205 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Spec.No.:- Bd.V.9 Page No. 555Third Floor |
| 206 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.Spec. No.:- Bd.V.38, Page Number 572 |
| 207 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec.No.:- Bd.V.43, Page No. 574 |
| 208 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page Number 574 |
| 209 | Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram. etc completeSpec. No.:- Bd.V.44, Page Number 575 |
| 210 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec.No.:- Bd.V.41, Page No. 573 |
| 211 | Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec.No.:- Bd.V.41, Page No. 573 |
| 212 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec.No.:- Bd.V.41, Page No. 573 |
| 213 | Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 Kilogram)Spec. No.:- As directed by Engineer in charge. |
| 214 | Removing chockes and leakages from down take G.I/CI/PVC pipe line on walls floor level by using zoola / scaffolding and rectify the same for functioning with all lifts etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 215 | Removing chockes and leakages from down take G.I/CI/PVC pipe line on walls floor level by using zoola / scaffolding and rectify the same for functioning with all lifts etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 216 | Removing chockes and leakages from down take G.I/CI/PVC pipe line on walls floor level by using zoola / scaffolding and rectify the same for functioning with all lifts etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 217 | Removing chockes and leakages from down take G.I/CI/PVC pipe line on walls floor level by using zoola / scaffolding and rectify the same for functioning with all lifts etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 218 | Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 219 | Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 220 | Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 221 | Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 222 | Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 223 | Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 224 | Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 225 | Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 226 | Filling tiles joint portion of flooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete.Spec. No.:- As directed by Engineer in charge.Ground Floor |
| 227 | Filling tiles joint portion of flooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete.Spec. No.:- As directed by Engineer in charge.First Floor |
| 228 | Filling tiles joint portion of flooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete.Spec. No.:- As directed by Engineer in charge.Second Floor |
| 229 | Filling tiles joint portion of flooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete.Spec. No.:- As directed by Engineer in charge.Third Floor |
| 230 | Providing and applying two coats of synthetic enamel paint of approved colour to new/old structural steel work and wood work in buildings, including scaffolding if necessary,cleaning and preparing the surface(excluding primer coat) etc. complete.Ground Floor |
| 231 | Providing and applying two coats of synthetic enamel paint of approved colour to new/old structural steel work and wood work in buildings, including scaffolding if necessary,cleaning and preparing the surface(excluding primer coat) etc. complete.First Floor |
| 232 | Providing and applying two coats of synthetic enamel paint of approved colour to new/old structural steel work and wood work in buildings, including scaffolding if necessary,cleaning and preparing the surface(excluding primer coat) etc. complete.Second Floor |
| 233 | Providing and applying two coats of synthetic enamel paint of approved colour to new/old structural steel work and wood work in buildings, including scaffolding if necessary,cleaning and preparing the surface(excluding primer coat) etc. complete.Third Floor |
| 234 | Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) |
| 235 | Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer incharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete.Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered. (b)- Powder coated Ground Floor |
| 236 | Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer incharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete.Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered. (b)- Powder coated First Floor |
| 237 | Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer incharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete.Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered. (b)- Powder coated Second Floor |
| 238 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete.Second Floor |
| 239 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.Upto Terrace level |
| 240 | Providing and fixing in position Powder Coated Aluminium tube Louvers for Duct covering with Aluminium rectangular pipe having overall dimension 50 X 25 x 1.5mm thick at weight 0.583 kg/Rmt. And 50X50X 5mm M.S. Tublar frame to support Aluminium Louvers. Aluminium Rectangular Tube fixed to MS Tube with 50 X 50X1.5mm thick Aluminium Angle (L-Clip) as per detailed drawing and as directed by Engineer in charge with all necessary aluminium sections fixtures and fastenings with all required screws and nuts etc complete.With Powder coating to aluminium section & Oil painting to the MS Section. Minor Changes in specification and fixing details are allowed due to propritary nature of the work but the final weight weight should not exceed the given value. The contractor to submit shop drawing indicating the method of installation for approval before prior to work etc. complete. Including transportation, loading , unloading ,Scaffolding, all floor lifts, including all other taxes etc, excluding GST. work will be carried out as per drawings and as per instructions given by site engineer in charge. Make:- HINDALCO, JINDAL, NALCO |
| 241 | Providing and fixing PVC Flooring 3mm thickness decorative/neutral color |
| 242 | Supply and installation of Single Bed @ 2066LX 900DX 400H PlywoodProviding and fixing Single Bed of Size 2066Lx900Dx400H without matress and pillow.Understructure:-The legs are made of Square tube of size 25x25mm made out of MS with a thickness of 1.2mm. All Metal components to be powdercoated to the thickness of minimum 50Microns DFT.Side Panel :- The side panels are made up of 16mm thick calibarated plywood with 1mm mica on outer side and 0.8mm mica on inner side. Allexposed edges are sealed with 2mm thick PVC edge Banding. The over all width of the side panel is 350mm.Head Board:- The headboard is made up of 16mm thick plywood with mica on both sides in approved shade 400mm high. All exposed edges aresealed with 2mm thick PVC edge Banding. Above 400mm headboard will be back cushion work done in size 900mm(W) x 400mm(H) which will haveuphostry of desired shade upto Rs. 400 / meterFoot Board: The footboard is made up of 16mm thick calibarated plywood with mica on both sides of size 900mm(W) x 400mm(H).All exposed edges are sealed with 2mm thick PVC edge Banding. Bed Base :- The Bed Base is made up of 12mm thick caibarated plywood with micaon both sides. |
| 243 | Supply and installation of Bed Side Table @ 600LX 400DX 600H Providing and Fixing Bed Side Table made up of 16mm thick calibarated plywood with mica on both side of approved shade. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one open shelf. The shelf is made of 16mm thick calibarated plywood with mica on both sides of approved shade. All exposed edges are sealed with 2mm thick PVC edge Banding. Table top is made in 25mm thick plywood with mica on both sides and 2mm PVC edgeband as approved. Back panel is made in 9mm thick plywood with mica on both sides |
| 244 | Supply and installation of Cupboard Size = 1450(W) x 600(D) x 2100(H) with 4 shutters PlywoodCarcass: Made up of 16mm thick calibarated plywood with mica on both sides of approved shade with 0.8mm thk PVC lippingShutter: Made up of 16mm thick calibarated plywood with mica on both sides of approved shade with 2.0mm thk PVC lippingDrawer : Drawer facia made up of 16mm thick calibarated plywood with mica on both sides of approved shade with 2.0mm thk PVClipping.Drawer 2 nos internal made up of 16mm thick calibarated plywood with mica on boths sides of approved shade with 9mm plywood basefinished with 0.8mm thk. PVC lipping.2 shelves made in 16mm thick calibarated plywood with mica on both sides of approved shade to be placed as per drawing and back panelin 9mm plywood with mica on both sidesHanger rod : Made up of Stainless steel finished with mirror polishedHandle : : Handle made up of mild steel and finished with chromeHardware- All necessary hardware for knockdown fitting like Minifix , wooden dowels, connector, L' Clip, Leveling Bolt with inserts, etc.complete as per Architect's Drawing and instructions of The Engineer In Charge. Edgeband - 2mm thick edgeband on all visible edges,0.8mm edgeband on all non visible edges, PVC edge banding are imported from Rehau or Dolken of Germany. Hardware - Ebco orequivalent. Edgeband - Rehau/Dolken or equivalent.,as per Architectural drawings to be approved by employer before entire scheme isfinalized and directed by engineer incharge. |
| 245 | Supply and installation of Entrance Shoe Rack / Tall Unit one side TV & work desk other side Plywood with laminateStudy table: 750mm(H) x 1500mm(W) x 600mm(D) / Study table overhead: 825mm (H) x 1105mm(W) x 400mm(D) / Study table tall unit:1575mm(H) x 395mm(W) x 400mm(D) / Pinup board: 1105mm(W) x 750mm(H) x 12mm(D) with fabric as approved Providing ,fixing, Fabrication and installation of study unit made with 16mm thick calibarated plywood with mica on both sides as per approved shade.It is having 2 drawers on left side and one drawer on right side. Overhead storage unit having 3 shutters with one shelf inside. Tall unit having 4 open shelves. T V Unit having laminate panelling with wooden battens as per drawing on right side of study table. Shoe Rack and entrance rack of size: 1800mm(W) x 2325mm(H) x 300mm(D) having 4 shutters with storage inside and one niche of size: 400mm(H) x988mm(W). To be made in 16mm calibarated plywood with mica on both sides of approved shade. 2mm edgeband on visible portion and 0.8mm edgebanding on inside parts. Includes stainless steel (SS) hinges, handles, and lockable hardware. Drawers are equipped with regular slidersHardware- All necessary hardware for knockdown fitting like Minifix , wooden dowels, connector, L' Clip, Leveling Bolt with inserts, etc. complete as per Architect's Drawing and instructions of The Engineer In Charge. Edgeband - 2mm thick edgeband on all visible edges, 0.8mm edgeband on all non visible edges, PVC edge banding are imported from Rehau or Dolken of Germany. Manufacturer of Plywood - Merino/GreenPly/Anchor or equivalent. Laminate - Merino/Greenlam/Century or equivalent. Hardware - Hettich/Hafele/ebco or equivalent. Edgeband - Rehau/Dolken or equivalent.,as per Architectural drawings to be approved by employer before entire scheme is finalized and directed by engineer incharge. |
| 246 | Supply of Chair -Recycled material chair with SS fitting |
| 247 | Supply and installation of Centre Table in teak wood with glass topGlass top 10mm thick in 600mm x 600mm with teak wood understructure having melamine polish as per photograph attached |
| 248 | Supply and installation of TV Unit: Plywood with micaSize: 900mm(W) x 600mm(H) x 400mm(D) having 2 shutters and 1 open shelf.To be made in 16mm calibarated plywood with mica on both sides as per shade approved |
| 249 | Supply of Wooden Serving Tray + 4 Coasters Set for Decoration | Tea Trays | Coffee Tray Tray |
| 250 | Supply of Analog 33 cm X 33 cm Wall Clock (Black and White, With Glass, Standard) |
| 251 | Supply of Design Pedal Dustbin 11 Litre Modern Lightweight Dustbin for Home and Office Dustbin |
| 252 | Supply of Matte/Glossy Finish Flower pot Circular Shaped Flower Pot for Modern Gardens\\" Artificial Plant with Pot (15 cm, Pink) |
| 253 | Supply and Fixing of Bathroom CabinetOver sink cabinet of size: 600mm x 600mm x 300mmTo be made in 18mm WPC with mica on boths sides |
| 254 | Supply of Toiletries-Shampoo holder, Body wash holder, Towel hanging bar SS, Dental Kit,Shaving Kit, ShowerCap,Luxurious Towels |
| 255 | Supply of Roller Window blinds -5' x 4' including |
| 256 | Supply of installation Shower Partition and LED mirror in bathroomSize: 2'10\\" x 7'8\\" toughened glass with all fitting included and LED mirror of size: 3' x 2'Saint Gobain or equivalent glass to be used |
| 257 | Supply and installation of CP & Sanitary Fittings- 2-Way Bib Cock,Wall Mixer with Shower Provision, Shower Arm, Tall Body Pillar Cock, Basin Bottle Trap, WC/Commode (EWC), Concealed Body for Flush Tank, Flush Tank Push Plate, Floor Drain Trap ( As per annexure-1 attached) |
| 258 | Supply of Doormat- MAXOSHINE or equivalent Microfiber Bathroom Mat Anti Skid-Highly Absorbent Super Soft Door Mats for Home Kitchen Living Room-2000 GSM Floor Mat-40 x 60 cm (Grey) |
| 259 | Supply of Mattress for Beds- Nilkamal or equivalent SLEEP Lite Dual Comfort 5 Inch Mattress | 10 Year Warranty| Reversible Design | Soft & Firm Sides | Superior HD Foam | Breathable Knitted Fabric | Bed Mattress | Single Size (75 x 36 x 5) |
| 260 | Supply of Pillow for Beds- Spaces Quilted Pillow or equivalent Set of 2 | Extra Soft Filled, Down Alternative Hypoallergenic Pillow (17 x 27 inch/ 43 x 69 cm) | Luxury Queen Size Bed White Microfiber Pillows |Neck Support, Machine Washable |
| 261 | Supply of Bedsheets- DECOMIZER or equivalent Cotton Feel All Around Elastic Fitted Glace Printed Single Bed Bedsheet with 1 Large Pillow Cover Fits Upto Mattress of 6 Inches,Pillow Size - 50 x 75 x CMS (Approx) 1 PCS, Beige Anokhi |
| 262 | Supply of Blankets- Cloth Fusion or equivalentMicrofiber Reversible 200 GSM AC Comforter Single Bed, Summer Blanket Quilt for Single Bed (Black & Grey) |
| 263 | Supply of notepad Memo Holder with Colorful Sticky Notes with Pen (Ocean Blue) Pocket-size Note Pad UNRULED 50 |
| 264 | Supply of Coffee Mug (x2), Glasses (x2), Holding Tray -Coffee Mug -Ceramic 250–300 ml,White / Neutral tones Plain or minimal pattern, |
| 265 | Supply of Digital Abstract Paintings- Room Décor 2' x 2' |
| 266 | Supply of SOFA SET (2 + 1 + 1)SOFA SET (2 + 1 + 1) Sofa frame to be made in hardwood with sleepwell 32D foam on seat and back and fabric as approved upto Rs. 400 / meter. |
| 267 | Supply of Reception Table (2100mm(W) x 750mm(D) x 750mm / 900mm(H))Reception Table (2100mm(W) x 750mm(D) x 750mm / 900mm(H)) as per design approved to be made in HDHMR with PU paint ofapproved shade. Having one pedestal having 3 drawers inside. Hardware- All necessary hardware for knockdown fitting like Minifix ,wooden dowels, connector, L' Clip, Leveling Bolt with inserts, etc. complete as per Architect's Drawing and instructions of The Engineer InCharge. Hardware - Ebco or equivalent as per Architectural drawings to be approved by employer before entire scheme is finalized anddirected by engineer incharge. |
| 268 | Supply of Refurbishment of wooden door (2400mm(W) x 2100mm(H))Existing door to be remodelled as per design provided with new hinges, lock, handles etc as selected by engineer in charge. Pu paint / PUpolish to be re-done and fixing the door on site with tower bolt , door stopper in place. |
| 269 | Supply and fixing of Back Panelling on wall behind reception table with charcoal sheet (4500mm (W) x 3000mm(H))Panelling on wall behind reception table with charcoal sheet in requested design along with polishing the same in Pu Paint / PU polish as per direction of engineer in charge. |
| 270 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 39 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 271 | Supplying, fixing and commissioning 2 pole RCBO 32/46A, with overcurrent,rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO |
| 272 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 273 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 274 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 275 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1460 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‗E‘ class insulation. |
| 276 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 277 | Supplying and erecting modular type (two module) electronic step regulatorfor fan, duly erected on provided plate and box with wiring connections complete |
| 278 | Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 279 | Supplying LED concealed type foot / step light with aluminium body forindoor/outdoor application suitable for 4W-6W LED including driver anderecting by making necessary arrangement / recess in wall to make it flush withsurface with 1 year warranty |
| 280 | Supplying & erecting inverter LED batten 20W tube light fitting withpolycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600mAh Lithium ion Battery with charging time of 8-10 Hours and backup time ofMin. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life ofminimum 25000 hrs. with overheating protection with 2 years warranty. |
| 281 | Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2750 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty. |
| 282 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduitwith 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch andrequired accessories as per specification No: WG-PW/SWW |
| 283 | Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WGPW/SW. |
| 284 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW |
| 285 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places. as per specification No: WG-MA/BW . |
| 286 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW |
| 287 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withPVC accessories on wall /ceiling as per specification No: WG-MA/CON. |
| 288 | Supplying and erecting PVC trunking (PVC casing-ncapping) of size 32 mm with accessories on wall/ceiling asper specification No: WG-MA/ |
| 289 | Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75mm height complete with necessary coupler plates & hardware. |
| 290 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as perspecification No: WG-MA/CC. |
| 291 | Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq.mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/A |
| 292 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recordingthe results as per specification no. EA-EP |
| 293 | Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI. |
| 294 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with jointsrequired. As per specification no EA-EP. |
| 295 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.pwd dsr 2021-22/1-8-1. |
| 296 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. PWD DSR 2021-22/1-8-2. |
| 297 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. PWD DSR 2021-22/ 1-8-10. |
| 298 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. Pwd dsr 2021-22/1-8-11. |
| 299 | Supplying and erecting ISI mark modular type 5 pin socket with safety shutters 3 module socket 6A 246V AC supply, duly erected on provided plate and box with wiring connections complete duly erected. |
| 300 | Supplying and erecting ISI mark modular type 32A, DP key tag switch with KEY TAG, duly erected on provided plate and box with wiring connections complete |
| 301 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specificationNo: WG-DM/PW |
| 302 | Dismantling the existing Telephone / Lan / Wan / TV cables and wires of all sizes along with casing-capping / conduit complete as per specification No: WG-DM/PW |
| 303 | Dismantling the existing aluminium /copper mains, submains wiring upto 10 sq.mm. along with accessories etc complete as per specification No: WG-DM/PW |
| 304 | Dismantling of existing fluorescent fittings of any type & size. |
| 305 | Dismantling the existing W.T. fluorescent fitting / S.V./M.V. / M.H. lamp /LED fitting from wall with brackets and making the site as original complete |
| 306 | Dismantling the existing ceiling fan /exhaust fan / cabin fan / bracket fan complete with accessories, G.I. down rod, frame etc. and making the site clear. |
| 307 | Dismantling the existing cables of all types & size up to 10 sq. mm. |
| 308 | Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/SD |
| 309 | Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP |
| 310 | Supplying, erecting, testing and commissioning hooters having high (100dB @1m) and low (94dB @ 1m) volume setting, group addressing facility allowingmultiple sounders to be activated with CRCA enclosure complete as perspecification no. FF-FAAS/HTR |
| 311 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as perspecification no. CB-LT/CU |
| 312 | Supplying, installing, testing and commissioning of 2 Zones Microprocessorbased conventional fire alarm control panel (FACP) with standard accessories, 16x2 Character LCD Display, provision for zone wise contact and beepsound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2Percentage RH (non- condensing) at 32 ± 2 Deg C complete as perspecification no. FF-FAAS/FACP |
| 313 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 classhaving minimum lumens output of 1600 Lumens/m, min. efficacy of 90lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f.>0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50including driver with 1 year warranty. |
| 314 | Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW |
| 315 | Wiring for plug on board with flush Switch socket, copper wiring and earthingas per specification No:WG-PW/SW |
| 316 | 2 Way Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduitwith 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch andrequired accessories as per specification No: WG-PW/SWWNote-3- of CSR |
| 317 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 318 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 319 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 320 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 321 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 322 | Supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 323 | Supplying and erecting modular type telephone socket one gang with safetyshutter, duly erected on provided plate and box with wiring connections complete. |
| 324 | Supplying, erecting & terminating co-axial copper cable low voltage grade trishieldedRG-11 as per specification no. WG-TW |
| 325 | Supplying and installing, testing & commissioning of digital (hybrid) typeEPABX of 6 x 32 extensions suitable upto 96 extensions complete |
| 326 | Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & speaker unit as per specification complete. |
| 327 | Supplying, installing, testing & commissioning IP telephone instrument as perspecification complete. |
| 328 | Supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephonecopper cable with poly-al laminate moisture barrier, |
| 329 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min.1.5mm thick MS sheet as per specification no. WG-TW |
| 330 | Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC |
| 331 | Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 332 | Supplying, fixing, and configuring 24 ports, POE switch in provided rack as perspecification No. WG-NWC/ENS |
| 333 | Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete |
| 334 | Supplying, installing, testing and commissioning 15W PA Column Speakerswith 15W RMS power in aluminium extruded cabinet, Moulded Plastci Covers &Metal mesh grill, frequency response 150-15,000Hz, operates on 100V line withpower taps of 15/10/5/2.5W in black or white color,With Mounting clamps &Necessary hardware, as per decesion by Engineer-in charge complete as perspecification no. PA-CS |
| 335 | Supplying, erecting, testing & commissioning Mixer Amplifier 120W RMSPower with Built-in MP3 player with remote control for USB, SD/MMCcard reader, with min 5 Mic & 2 Aux Input, bluetooth facility, frequencyresponse 50-15,000Hz ±3dB, Signal to noise ratio between 60dB to 65dB min 5LED array for output level monitoring. It Shall have Line Output to connect aBooster Amplifier and Preamplifier Output. The Amplifier shall have SpeakerOutputs - 4Ω, 8Ω, (Low Impedence) and 70V & 100V/(High Impedence), andcan operate on 220-240V Power Supply & DC : 12V (facility to instant transfer toDC power if AC power fails) complete as per specification no. PA-MA |
| 336 | Supplying & erecting Microphone floor stand with Height 920-1500 mm, BaseDia- 230 mm, min. weight 3.6 kg with superior quality of chrome plating/powder coating (resistant to rust & corrosion) having sturdy mechanism forensuring trouble free movement and positioning of microphone complete as perspecification no. PA-MFS |
| 337 | Supplying and erecting ding dong / electronic musical type call bell withheavy duty coil suitable to operate on 230V A.C. supply erected on polisheddouble wooden block / sunmica block of suitable size. |
| 338 | Supplying and erecting modular type bell-push 6A/10A on provided plate andbox with wiring connections complete |
| 339 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 340 | Supplying and erecting M.S./CRCA cabinet for housing double hose pipewith nozzle (size 750 x 600x 250 mm.) made from 16 SWG sheet and angleiron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and lockingarrangement with necessary fixing material such as rubber bidding etc. dulypainted in post box red colour( Code 538 of IS 5) |
| 341 | Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hosepipe, 15m in length, fitted with necessary accessories complete as perspecification no. FF-FFA/RRL |
| 342 | Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ |
| 343 | Supplying, installing, testing & commissioning of 32/40 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI outputof 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface,support multibrand network Cameras,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR |
| 344 | Supplying & erecting of High definition 2 Megapixel IP IR Bullet Camera with following features :Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS,Video Resolution : minimum 1920 x 1080Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 30m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 30m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB,Built in microphone.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no.CCTV-CAM. |
| 345 | Supplying & erecting 4 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, Maximum sustained transfer rate 150MB/Sec to 180MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 64, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 346 | Supplying and fixing 42U floor mount server rack (Dimension-DxWxH –800x1000x2070 mm) as per specification no. WG-NAS/RAK |
| 347 | Supply installation testing and commissioning of 40A 230V 50/60Hz Power Contactor required as per specification. |
| 348 | Supply installation testing and commissioning of Energy Key Tag with Time Delay as per site requirement. |
| 349 | Mini Fridge-45 Ltr, 2 Star, Mini Refrigerator with Freezer, Direct Cool,Black,Product Dimensions 48D x 50W x 55H Centimeters Brand Blue StarCapacity 47 litres Configuration Compact Freezer-on-Top |
| 350 | Split AC-1 Ton 4/5 Star, 5 Years Comprehensive Warranty, 5-in-1 Convertible Cooling, Inverter Split AC (Copper, Heavy-Duty Cooling at 52 Deg Celcius, AC 1T EI 12IINV5R32-WWR, White)Capacity 1 Tons Cooling Power 3.4 Kilowatts Special Feature ConvertibleProduct Dimensions 23D x 81W x29.5H Centimeters |
| 351 | LED Smart TV-Screen Size- 43 Inches, Q4 AI Processor | 100% Color Volume with Quantum Dot | Knox Security| Endless Free Content | 4KUpscaling |
| 352 | Electric Kettle-Rapid Electric Kettle 1.8L | 1500 Watts | Stainless Steel Hot Water portable Electric Kettle for Home, Office | Auto Cut-Off with Wide Mouth | Cool-touch Handle andSingle-Touch Lid Lock |
| 353 | Bathroom Gyser -Arno Neo 15-L 5 Star Rated Storage Water Heater (Geyser) with Advanced 3 Level Safety, |
| 354 | Iron-Steam Iron |
| 355 | Hair Dryer-1200 Watts Foldable Hair Dryer; 3 Heat Settings With Cool Shot (Hot/Cool/ Warm), Heat Balance Technology|Cool Turquoise|Your Perfect Blow Dry Companion For Effortless Hair Styling|Hd3151 |
| 356 | Smart Lock for the Main Door-Fringer Print, Passcode, Access card, Mobile app, Machenical Key |
| 357 | Bedside flexible 3W reading light Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail