| 1 | Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutter from the frame) each including Builders Hardware and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed. |
| 2 | Taking down shutters of any description exc 1 Sqm and n.exc 2.00 Sqm each including Builders Hardware and removing from site complete all as specified and as directed. |
| 3 | S&F factory made Pressed steel frames confirming to IS, having profile of size 125 x 60 mm, 1.25 mm thick MS Sheet for doors with one or more rebates including necessary supply and fixing lugs, lock strike plate, etc. 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed. |
| 4 | S&F of factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with 19x19mm MS square tube and 1.2mm wall thickness complete all as specified and as directed. |
| 5 | S&F factory made pressed steel frames confirming to relevant IS, having profile of size 105 x 60 mm, 1.25 mm thick MS Sheet for doors with one or more rebates including necessary Supply & fixing lugs, lock strike plate, etc. 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed. |
| 6 | S&F of 35mm thick 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rails and panel of 9mm BWP comercial ply or 12 mm thick veneered particle board with comercial veneering on both faces. The size of rail and style as per IS-1003 Part-I klin seasoned and chamicaly pressure treated complete all as specified and as directed. |
| 7 | S&F for factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed. |
| 8 | S&F of factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails MS frame shall be covered with heat moulded plain clolur PVC `C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stile and plain clolur PVC sheets for top rail lock rail & buttom rail on either side and as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with slolvent cement, suppling & fixing in the frame at site as per manufactures instruction complete all as specified and as directed. |
| 9 | Easing of door shutters for properly closing/opening, tighting of hinges or changing the position of hinges, adjustment of tower bolts sliding bolt etc complete all as specified and as directed. |
| 10 | M&L for refixing of shutter of any description exc 1 Sqm and n.exc 2 Sqm each of same opening doing resecuring or easing & adjusting without taking down complete all as specified and as directed. |
| 11 | Taking down shutters with wooden frame of cupboard of any description exc 1 Sqm and n.exc 2.00Sqm each including Builders Hardware and removing from site complete all as specified and as directed. |
| 12 | M&L 18-19 mm thick pre laminated partical board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to MS frame work complete all as specified and as directed. |
| 13 | S & F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised complete all as specified and as directed. |
| 14 | S&F of mild steel butt hinges, medium weight cold rolled of size 100mm complete all as specified and as directed. |
| 15 | Taking down old/ rusted varandah net/jali including frame of any description etc complete all as specified and directed. |
| 16 | S&F rolled mild steel equal angles framed work confirming of Fe-290 (Gde-E-165) including welding, drilling for holes as necessary for fixing door frame, verandah jali, mesh and staple etc complete including dismantling wrought iron or mild steel all as specified and directed |
| 17 | S&F MS flat iron as in support for veranda jali,mesh including welding,drilling holes and fixed to frame with nuts red sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc confirming to Fe-290(Gde-E-165) etc complete including dismantling wrought iron or mild steel all as specified and directed. |
| 18 | S&F in repair aluminium handles cast type anodised 150mm of size complete all as specified and as directed |
| 19 | S&F in repair 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed |
| 20 | S & F in repair 150 mm long Mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and as directed |
| 21 | S & F in repair 150 mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed |
| 22 | S&F in repair Aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed |
| 23 | S&F steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay,complete without glazing bars, dovetailed or welded all as per Drawing No. SZ/TD/219/99 Sheet 1/2 & 2/2 dated 17 Jun 1999 complete as specified and as directed |
| 24 | All as per item no 23 above but without glazing bars complete all as specified and as directed. |
| 25 | All as item No 23 above but fixed type complete all as specified and as directed. |
| 26 | S&F in repair steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or without glazing bars all as specified and as directed. |
| 27 | M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; ramework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 28 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 29 | M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of Pink primer complete all as specified and as directed. |
| 30 | Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips and providing & fixing new one complete all as specified and as directed. |
| 31 | S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed |
| 32 | M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in frame filling , gaps in between glazed & fly proof steel window, cills, railling up to 60 cm in height etc including necessary form work as required complete all as specified and as directed |
| 33 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 34 | S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 35 | Material and labour for brickwork with fly ash bricks, old size, having compressive strength not less than 75Kg sqcm, straight or curved on plan exc 6 M mean radius in built in cement and sand mortar 1:6 complete all as specified and as directed. |
| 36 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick walls or concrete surfaces in mixed with water proofing compound by weight of cement or as per manufacturer instructions, finished even & fair without using extra cement including taking out plaster as required complete all as specified and as directed Note- WPC will be measured and paid seperately seperatly. |
| 37 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even and fair without using extra cement including taking out plaster as requiredcomplete all as specified and as directed. |
| 38 | M&L for rendering 15 mm thick cement plaster on other than fair surfaces of brick work in cement mortar (1:6) c including taking out plaster as required complete all as specified and as directed. |
| 39 | Supply only liquid water proofing compound conforming to relevant IS complete all as specified and as directed. |
| 40 | M&L for for preparation of newly wall plastered surfaces and applying three coats of white wash on wall to match the existing colour complete all as specified and as directed. |
| 41 | M&L for preparation of newly ceiling plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed |
| 42 | M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and distempering walls by applying one coat of acrylic based distemper emulsion of any tint/shade with roller including wall putty / white cement wherever required to fill the wall cracks/holes complete all as specified and as directed. |
| 43 | M&L for preparation of old treated surface of ceiling by brooming down or steel wire brushing; scrapping down smoke root, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash / colour wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed. |
| 44 | M&L for Granite (of any type) 15-18mm mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and olishing 15mm thick screed bed or bedding layer of cement mortar 1:6 for floor finishes including dismantling floor, hearth or tiling complete all as specified and as directed. |
| 45 | M&L non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick screed bed or bedding layer of cement mortar 1:6 for floor finishes including dismantling floor, hearth or tiling complete all as specified and as directed. |
| 46 | M&L Glazed ceramic coloured tiles in vertical surface 350x250x7/450x350x7mm thick set and jointed in neat cement slurry and pointed white or colour cement to match including dismantling plaster or tiling complete all as specified and as directed. |
| 47 | M&L non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick screed bed or bedding layer of cement mortar 1:6 for floor finishes including dismantling floor, heart or tiling complete all as specified and as directed. |
| 48 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces to recive a wall tiles using cement morter 1:4 Complete all as specified and as directed |
| 49 | M&L for 75 mm thick cement concrete type C2 1:3:6 with 40 mm graded stone aggregate as in plinth protection etc finishing the surface with out using extra cement taking demolition of cement concrete unreinforced complete all as specified and as directed. |
| 50 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed. |
| 51 | S&F of Tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. |
| 52 | Refixing of old steel tubing and conections in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed |
| 53 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and as directed |
| 54 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed |
| 55 | S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed |
| 56 | Supplying & fixing of PVC water storage tank 500 ltr capacity HDPE double layered, cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection including locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms) complete all as specified and as directed.Note : GI inlet, outlet & wash out pipe will be measured and paid separately. |
| 57 | S & F in repair Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP waste coupling, PVC connection 450 mm long, waste pipe & removing the existing Basin, cutting for and pinning ends of brackets or erecting stand complete all as specified and as directed |
| 58 | S&F vitreous china squatting pan\\"Orissa\\" pattern size 580x440mm white with intgeral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S\\" trap fron or back inlet etc including connection to trap tand flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one complete all as specified and as directed |
| 59 | S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection 450 mm long PVC flush pipe of required length etc complete all as specified and as directed |
| 60 | S&F in repairs vitreous china wash down water closet pedestal pattern white excluding fixing bolts, flushing cistern and flush pipe complete but including PVC seat cover with aluminium/PVC hinging devices & EWC Jet chromium plated with 1.00 mtr long PVC connection pipe etc complete all as specified and as directed. |
| 61 | S & F in repair grating doom 125mm dia with waste hole of PTMT (min wt 40 gms) complete all as specified and as directed. |
| 62 | S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 63 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches or in floors including taking down complete all as specified and as directed. |
| 64 | S&F 110mm dia PVC SWR bends of any radius without access door including taking down complete all as specified and as directed |
| 65 | S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door including taking down complete all as specified and as directed. |
| 66 | S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal including taking down complete all as specified and as directed. |
| 67 | M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Fins, fascias, louvres, parapets, and railings , newels, balustrade & the like including demolition of reinforced concrete complete all as specified and as directed |
| 68 | Use and waste for formwork to fins, louvers, fascia. etc fair finished surfaces of concrete flat complete all as specified and as directed. |
| 69 | M&L Mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed. |
| 70 | M&L for 10mm thick screed bed or bedding layres in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP base plymeric membrane, finished even and smooth without using extra cement complete all as speified and as directed including taking down tarfelt with cement plaster from roof surface complete all as specified and as directed. |
| 71 | M&L for providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating in 4 coats of application:- (a) Applying primer coat with Primer @ 0.3 kg /sqm as per manufacturer instruction.(b) Over priming coat applying water proofing coat as per manufacturer instructions with fibre reinforcement @ 0.75kg/sqm on the flat or vertical surfaces over parapet wall and ensure that there are no bubbles of creases. Overlapping of the fibre is a minimum of 50mm and allow this coat to dry for a period of 2-6 hrs depending on the atmospheric condition. (c) Applying second coat of water proofing coat @0.75Kg/sqm.(d) Applying final coat of primer @ 0.08kg/sqm after 2nd coat has dried properly. Note : Water Proofing treatment shall be carried out by authorised applicator approved by the manufacturer. |
| 72 | M&L for rolled mild steel work in tubular trusses such as roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcs including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 including taking down complete all as specified and as directed. |
| 73 | S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including taking down complete all as specified and as directed |
| 74 | S&F in repair of ball valves of 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fix (minimum weight 20gms-210 gms) complete all as specified and as directed. |
| 75 | S&F in repair 15mm dia Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 76 | S&F in repair consealed stop cock CP, cast copper alloy gancy type with long shank and cup for 15mm pipe complete all as specified and as directed. |
| 77 | S&F in repair 15mm bore stop cock of PTMT any colour high pressure screwed for iron pipe and fixed. (minimum weight 15mm-90gms) complete all as specified and as directed. |
| 78 | S&F in repair of chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 79 | S&F in repairs 15mm bore pillar taps, capstan head, cast copper alloy, chromium plated, screwed down high pressure with or without lettered 'HOT or 'COLD' long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. |
| 80 | S&F 600mm x 450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 81 | S&F in repair health faucet connecting with 15mm dia pipe with chromium plated (CP) finishing etc complete all as specified and as directed. |
| 82 | S&F in repair 15mm dia brass chromium plated angle cock complete all as specified and as directed. |
| 83 | ELECTRIFICATIONTaking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed. |
| 84 | Taking down carefully existing old/unsv sub main wiring of any size/descripption as existing at the sit including making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. |
| 85 | M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FRLSH (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles complete all as specified and as directed for the following :- One Light point controlled by one, one way switch |
| 86 | All as per item No 85 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator |
| 87 | All as per item No 85 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 88 | All as per item No 85 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . |
| 89 | All as per item No 85 here in before but for one bell point controlled by one, bell switch 5 Amps |
| 90 | All as per item No 85 here in before but for light point controlled by two way switch Amps |
| 91 | All as per item No 85 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 92 | S & F switch piano single pole flush type 5 amps, 230 volts one way complete all as specified and as directed. |
| 93 | S & F bell push flush type 5 amps, 230 volts complete all as specified and as directed. |
| 94 | S & F switch piano single pole flush type 5 amps, 230 volts two way complete all as specified and as directed. |
| 95 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed. |
| 96 | S&F socket 2 in 1, 5 Pin, 5/15 amps, white ivory finish flash type complete all as specified and as directed. |
| 97 | S & F switch piano single pole flush type 15 amps, 230 volts one way complete all as specified and as directed. |
| 98 | S&F Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with, complete all as specified and as directed. |
| 99 | S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed. |
| 100 | S&F in replacement ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 101 | S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed. |
| 102 | S & F Call bell Ding dong, 230 Volt single phase all as specified and as directed. |
| 103 | S & F deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed. |
| 104 | S&F in replacement hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and directed. |
| 105 | S&F in replacement hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed. |
| 106 | S&F in replacement hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed. |
| 107 | S&F in replacement hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed. |
| 108 | S&F in replacement LED tube light 1 X 20 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting completeand as directed. |
| 109 | S & F in replacement Inverter retrofit tube light of 20W with square profile and polycarbonate channel, lithium Ion battery with charging time 8 Hours-10 Hours and backup time upto 4 Hours with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 110 | S & F in replacement Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete incl removal of old unserviceable fitting complete all as specified and as directed |
| 111 | S & F in replacement Post top lanterns 15 watt LED light fitting ,new generation, energy saving, environmental friendly, longlife with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories intenally prewired including connecting up with three core twisted flexible copper conductor cable up to cealing rose and necessary mounting arrangements, including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 112 | M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLSH cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit with complete all as specified and as directed. Note:- Two runs of conductor copper and one run of earth conductor and one run of PVC pipe shall be measured and paid as one unit separately. |
| 113 | All as per item No 112 above but using two run 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed. |
| 114 | M & L in replacement for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incomming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 115 | S & F in replacement sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete including removal of old unsv sheet metal enclosure complete all as specified and as directed. |
| 116 | S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including taking down of old unsv sheet metal enclosure complete all as specified and as directed. |
| 117 | S&F in replacement MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed. |
| 118 | S&F in replacement MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed. |
| 119 | S&F in replacement MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one complete all as specified and as directed. |
| 120 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion & taking down old existing unserviceable one complete all as directed and as specified. Please Enable Macros to View BoQ information |