| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm RLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 4 sq. mm |
| 6 | Supplying & laying of one Number multi core flexible PVC outer sheathed copper conductor suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 7 | 3 x 1.5sq. mm (in the existing masonry open duct / existing pipe /tray as required) |
| 8 | 3 x 6 sq. mm (in the existing masonry open duct / existing pipe /tray as required) |
| 9 | Supplying & laying of one Number following core PVC/XLPE insulated with PVC outer sheathed armoured Aluminium conductor cable suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 10 | 3 x 4 sq. mm (on wall / existing tray) |
| 11 | Supplying and fixing of following sizes of PVC trunking profile along with accessories fixing on wall surface and making good the same as required. |
| 12 | 50x 50 MM |
| 13 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But Without MCB/RCCB/Isolator) |
| 15 | 16 way, Double door |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | Single Pole |
| 18 | Supplying and fixing 63 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Double pole (63 AMP) |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 21 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 22 | Supplying and Fixing 450 mm (18”) heavy duty industrial Wall mounting Air circulator suitable for operation on 230 volt, ±10%, 50 Hz supply having 1440 RPM, 3 Nos blades and air delivery 150 cubic mtr /min. to be fixed by making necessary arrangements on the wall i/c testing etc. as reqd. |
| 23 | Supply of Pendant Circular diffused Industrial Well glass robust and modern lowbay Industrial 35-watt LED luminaire with unconventional breakthrough design for illuminating mid and high ceiling of Housing made-up PDC Aluminium with UV Stabilized Injection moulded PC Diffuser to ensure effectively light distribution. Luminaire to have 220-240V AC (Input load type) power supply, Minimum luminaire efficacy >110 lm/W, Minimum lamp life L70B50 ≥50,000hrs, CRI ≥ 80, THD < 10%, Power factor >0.95. Integral switched ON-OFF Driver with\inbuilt SPD 4KV and IP 65 protection. control unit, all mounting and installation accessories. |
| 24 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body With built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as er LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 25 | 70-watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). |
| 26 | Supplying and fixing of SMC junction /pole box having size not less than 200mm x140mmx95 mm minimum IP 65 rating, Din mounting with 6 amp MCB support/c 20mmx3mm Aluminium bus bar support connection, eartthing i/c complete fixing and connection as required. |
| 27 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 28 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 29 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 30 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 31 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 32 | 200 mm dia |
| 33 | 300 mm dia |
| 34 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required: |
| 35 | 200 mm dia |
| 36 | 250 mm dia |
| 37 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. |
| 38 | 200 mm dia (wall thickness 6.3 mm) |
| 39 | 250 mm dia (wall thickness 6.3 mm) |
| 40 | 300 mm dia (wall thickness 7 mm) |
| 41 | 400 mm dia (wall thickness 7 mm) |
| 42 | Supplying, Installation, Testing & Commissioning of Centrifugal storm/sewage pump having single stage, suction 250 mm dia, delivery 300 mm dia, discharge min 1200 cum/hr at minimum head 18 mtr semi open mixed flow pump, Stainless Steel CF8 or CF8M impeller & solid handling capacity min. 75 mm dia PTFE gland packing complete with not less than 127 HP coupled with tyre coupling to suitable BHP, 1500 rpm water cooled with radiator, diesel engine conforming to relevant IS standard and CPCB-IV norms amended upto date complete with 12/24 volts electric standing equipment with lockable rack of battery, diesel tank exhaust pipe extended upto suitable height outside pump house duly insulated with 50 mm thick glass wood with 1.00 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indication, painted with Blue colour etc. as required.a). MS fabricated, common base plate, foundation bolts with antivibration pads etc. complete as reqd. |
| 43 | 127 BHP/93.57KW (1200Cum/hr@18M Head) |
| 44 | Supply installation and testing and commissioning of centrifugal Storm/Sewage mixed flow type pump set having single stage, suction 200 mm dia, delivery 200 mm dia, discharge minimum 650cum/hr at minimum head 15 mtr, semi open mixed flow pump, Stainless Steel CF8 or CF8M impellers & solid handling capacity Min. 75mm with hardened Stainless Steel (SS410) shaft sleeve to protect the shaft from wear at the gland packing area, gland packed stuffing box complete with not less than 75 HP TEFC 415 V 50 HZ 1486 rpm, IE3 Class horizontal electric motor coupled (Factory Coupled) on a fabricated base plate through a set of flexible couplings with 6 Nos AVM pads etc. as required. |
| 45 | 75 HP/55 KW (650cum/hr@15M Head) |
| 46 | Supplying, fixing, testing & commissioning of following manually operated Oil immersed drum type Star Delta Motor Starter with double contact heavy duty and cable entry box, oil tank with oil complete with SS enclosure and operation handle complete etc. as reqd. |
| 47 | 100 HP |
| 48 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 49 | 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 50 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 51 | 3 x 95 sq. mm (in the existing masonry open duct/cable tray as required) |
| 52 | 3.5 x 400 sq. mm(in the existing masonry open duct/Cable tray as required) |
| 53 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 54 | 3 x 95 sq. mm (on wall surface as required.) clamped with 25/40 X 3 mm MS flat clamp |
| 55 | 3.5 x 400 sq. mm (on wall surface as required.) clamped with 40 X 3 mm MS flat clamp |
| 56 | Supplying & laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 57 | 3.5 x 400 sq. mm (in DWC/Pipe /duct/trench) |
| 58 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as require |
| 59 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 60 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 61 | 3 X 95 sq. mm (38mm) |
| 62 | 3 X 120 sq. mm (45mm) |
| 63 | 3½ X 400 sq. mm (82mm) |
| 64 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required |
| 65 | 250 A,36KA, FPMCCB |
| 66 | 630 A,50KA, FPMCCB |
| 67 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc. as required. |
| 68 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 69 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 70 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 71 | 375 mm width X 50 mm depth X 2.0 mm thickness |
| 72 | Laying, fixing & dressing of unmanaged existing one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size (i/c 2 core/3 core/3.5 core) on existing cable tray by the means of removing the termination of existing cable for relaying and reconnection the cable as required. |
| 73 | Upto 35 sq. mm (clamped on 1 mm thick saddle) |
| 74 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3 mm MS flat clamp) |
| 75 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25 /40 X 3 mm MS flat clamp) |
| 76 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40 X 3 mm MS flat clamp) |
| 77 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 78 | Hot finished welded type tubes |
| 79 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 80 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 81 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required. |
| 82 | Providing and fixing of 4.5Kg Carbon Dioxide type (Co2) fire extinguisher confirming to IS 15683 duly enamel painted fully charged, wheel release type valve, delivery hose horn locking arrangement, operating temperature: 30 Deg C to +55 Deg C i/c wall mounting MS. bracket etc. complete as required. |
| 83 | Supplying and laying of rubber Mat of dimension as required as customized as per floor of site having thickness 2.5 mm to withstand 11Kv dielectric strength as per latest IS 15652-2006 etc. as required. |
| 84 | Credit for old dismantled motor 75HP pump set |
| 85 | Credit for old dismantle materials like Panel, MCCB, Cables, pipe, Valves, MS and starter etc. Please Enable Macros to View BoQ information |