| 1 | Mechanical Works |
| 2 | Installion of Air curtain |
| 3 | EAS6,S.Steel Air Curtain (6 feet/Air Throw 21 M/S) at PET-CT SCAN |
| 4 | EAS5,S.Steel Air Curtain (5 feet/Air Throw 21 M/S) at UPVC door door of near 8 passenger lift OPD building ground floor, at UPVC door of near room 18 and 20 near OPD building ground floor, Radiology main entrance |
| 5 | EAS3,S.Steel Air Curtain (3 feet/Air Throw 21 M/S) at UPVC door near canteen OPD building first floor |
| 6 | EAS4,S.Steel Air Curtain (4 feet/Air Throw 21 M/S) at Left and Right UPVC Door of pharmacy portion OPD building ground floor |
| 7 | EX01,Sensor Slim Air Curtain (1 Door) |
| 8 | EX01,Sensor Slim Air Curtain (2 Doors With Siemens Contractor) |
| 9 | Installation |
| 10 | PVC Curtain |
| 11 | Premium PVC Strip Curtain 3mm (CRC Hookons) (PVC Strip Thickness 3mm including CRC hookons Hardware 2mm) DOP PREMIUM QUALITY HEIGHT- 7 FT, WIDTH-3.5 FT TOTAL- 30 SQFT HSN-39269099 |
| 12 | Premium PVC Strip Curtain 3mm (CRC Hookons) (PVC Strip Thickness 3mm including CRC hookons Hardware 2mm) DOP PREMIUM QUALITY HEIGHT- 7 FT, WIDTH- 8.8FT TOTAL- 69.75 SQFT , 69.75 x 4=279 Sqft HSN-39269099 |
| 13 | Installion Angle brackets or specific mounting accessories will incur additional charges. No ceiling or electrical work will be performed by our engineer |
| 14 | Electrical Works |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 15/16 A switch |
| 17 | 6 pin 15/16 A socket outlet |
| 18 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 19 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 20 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 21 | 1 or 2 Module (75mmX75mm) |
| 22 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 23 | 1 or 2 Module |
| 24 | 25 amp modular SPMCB, ‘C’ curve |
| 25 | Civil Works |
| 26 | Providing and fixing false ceiling at all height including providing and Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm cic, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 27 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part |) :2011 (Board with BIS certification marks) |
| 28 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 2 85%, Thermal Conductivity k = 0.052 - 0.057 wim K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm_ thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 29 | With 20 mm thick beveled tegular mineral fibre false ceiling tile |
| 30 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. |
| 31 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 32 | Providing and fixing approved quality machine pressed phenol formal dehy de bonded commercial/marine ply wood of approved size and fixing the same with necessary nails/screws/adhesive in partition cupboard shelves/ktichen/cabinets/flush doors etc. at all floors and locations in quantities as required at site in following thickness including 6 mm thick T.W.lipping patti at all exposed edges with nails/screws/hardwares/adhesive wastage in cutting, transportation etc. complete all as directed by the Engineer-In-Charge. |
| 33 | Marine ply |
| 34 | Providing and fixing 1.0mm thick approved make laminate of required colour over existing surfaces along with the adhesive all as required specification design etc. complete as specified and directed by Engineer-In-Charge. |
| 35 | 1.00 mm thick Please Enable Macros to View BoQ information |