| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed. |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and directed |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed. |
| 5 | M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundation complete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and directed. |
| 7 | Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm, 2 core multi-stranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed |
| 8 | All same as per item No 7 here-in-before but cross-sectional area 10 Sqmm, 4 Core |
| 9 | All same as per item No 7 here-in-before but cross-sectional area 16 Sqmm, 4 Core |
| 10 | All same as per item No 7 here-in-before but cross-sectional area 25 Sqmm, 3.5 CoreNote : For Sl No 7 to 10, necessary excavation shall be measured and paid under respective items of the same schedule separately. |
| 11 | M&L for preparing of old faded paint surface and painting with one coat of synthetic enamel paint to existing LT PCC/RCC/Steel tubular poles of size 9 m long up to the height of 1.2 m from the bottom with approved white and blue colour alternatively including pole number with paint same as existing earlier complete all as specified and directed |
| 12 | M&L for preparing of old faded painted surface of 9 m long steel tubular pole complete including all accessories such as cross arms, bracings, brackets etc and painting with two coats of aluminium paint of approved make including writing pole number with paint same as existing earlier complete all as specified and directed |
| 13 | Supply and fix in repairs of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed |
| 14 | Supply and fix in repairs of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed |
| 15 | Supply and fix in repairs of LED street light fitting 72 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed |
| 16 | Supply and fix in repairs of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed |
| 17 | Supply and fix in repairs of energy saving rectangular LED flood light fitting 150 Watts 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed |
| 18 | Supply and fix in repairs of energy saving rectangular LED flood light fitting 200 Watts 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed |
| 19 | Supply and fix in repairs of energy saving rectangular LED flood light fitting 250 Watts 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed |
| 20 | Repair and maintenance of all type Street/Security light fittings 45/60/70/90 watt capacity and flood light fittings 150/170/200/250 watt, solar street light fittings 10/12 watt capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the same pole/place complete all as specified and directed |
| 21 | Supply and fix in repairs of terminal box made out of made up of FRP/ Polycarbonate and locking arrangements of size 200x140x95mm Including, Backlite 4 way connector, MS Clamps suitable for pole, PCC/MS/GI/rail etc. with bolt, nut and washer, electrical connections including MCB SP 6-32 Amps complete all as specified and as directed |
| 22 | Supply and fix in repairs of pole mounted junction box (Street light box) made up of FRP/ Polycarbonate with sliding type doors fits to base by 3 phase busbar insulator - 04 Nos for street lighting system with nuts and bolts with fixing arrangement outdoor type of dimension 240x130x110 mm for with suitable screen printed skull and bones for danger notice on middle and top cover of the box complete all as specified and directed |
| 23 | Supply and fix in repairs of three single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size and one single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing unserviceable one complete all as specified and directed |
| 24 | Supply and fix in repairs of three core PVC cable, FRLS with copper conductor round cable 1.5 Sqmm for connection from junction box to street light fittings complete all as specified and directed |
| 25 | Supply and fix in repairs of 415V 10 KA 'B' curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB with connection testing and commissioning complete all as specified and directed |
| 26 | Supply and fix in repairs of 230V 10KA 'C' curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the Junction box/DB with connection testing and commissioning complete all as specified and directed |
| 27 | M&L for boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4 mpa working pressure complete all as specified and directed |
| 28 | Supply and laying of GI tubing light grade 50 mm bore in trenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed |
| 29 | Supply and laying of GI tubing light grade 40 mm bore in trenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed |
| 30 | Supply and fix in repairs of driver suitable for 45-Watt LED light fittings and testing complete all as specified and directed |
| 31 | Supply and fix in repairs of driver suitable for 60-Watt LED light fittings and testing complete all as specified and directed |
| 32 | Supply and fix in repairs of driver suitable for 70/72-Watt LED light fittings and testing complete all as specified and directed |
| 33 | Supply and fix in repairs of driver suitable for 90-Watt LED light fittings and testing complete all as specified and directed |
| 34 | Supply and fix in repairs of driver suitable for 150-Watt LED flood light fittings and testing complete all as specified and directed |
| 35 | Supply and fix in repairs of driver suitable for 200/250-Watt LED flood light fittings and testing complete all as specified and directed |
| 36 | Supply and fixing in repairs of 7 metre high hot dipped octagonal poles with 130mm bottom dia & 70 mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade 'J\\" type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide with etc as required including dismantling and taking down old unserviceable RCC pole complete all as specified and directed |
| 37 | Supply and fix in repairs to steel tubular street light pole 6 mtr high with pure polyester coated having base plate 200x200x12mm thick bottom dia 114mm(OD)x3mm thk x 2mtr long , middle portion 88.9mm(OD) x 3mm thick x 2 Mtr long , top dia 76mm (OD) x 2.5mm thick x 2 Mtr long inbuilt junction suitable for connection of 3.5 core cable of size upto 25 Sqmm 3.5 Core with SMI -5 Design single arm bracket of size 42mm (OD) x1 mtr long and 2mm thick with GI M16 x 600 mm foundation bolt & nut assembly including dismantling and taking down old unserviceable pole complete all as specified and directed. |
| 38 | Supply and fix in repairs of bracket made out of GI tubing single piece bended type(not welded) at proper angle of size 40 mm dia, light grade 120cm long including painting with aluminium paint over one coat of red oxide to the bracket ,MS clamps 02 Nos with 04 Nos nuts bolts and washer etc including 4 sqmm 2.0 core flexible Copper cable PVC insulation 6.5 mtr long in PVC conduit with clamp U type from junction box to connecter of street light fitting complete all as specified and directed. |
| 39 | Supply and fix in repairs of steel tubular swaged poles with cast iron base plate of size 300 mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with Sky Blue & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over Sky blue painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide including dismantling and taking down old unserviceable RCC poles complete all as specified and directed. |
| 40 | Supply and fix in repairs of aesthetically designed decorative hot dipped galvanised mild steel step pole of 3 mtrs with grey powder finish window - Plasma cut & Duly chamfered opening window of 300x10mm including taking down existing unserviceable RCC pole and light fitting complete all as specified and directed. |
| 41 | Supply and fix decorative arms in different designs, shaped and lengths to compliments in EROS LED Post tops and Poles family suitable for Orbit plus S round arm for pole complete all as specified and directed |
| 42 | Supply and fix in repairs of “Lithium based Energy Efficient Integrated Solar Street Light of 40Watt” in rust proof Aluminium housing with Monocrystalline Solar PV Panel of 75W(-0/+4W) Mono , Lithium Battery 12.8V, 42AH(BIS Certified), IP 65, High brightness W-LED(150 Lm/watt) lamp with Aluminium reflector for better light distribution, Color Temperature 6500K +500K, Microcontroller based charge controller cum driver, automatic dimming function( with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 5 degree C to (+) 45degree C, Charging time 1 day and Autonomy 2 days with dimming Protections: Short Circuit, overload, Reverse polarity and battery protections complete all as specified and directed |
| 43 | Supply and fix in repairs of unserviceable batteries of solar street light with maintenance free sealed battery of size 120 AH 12V including taking out old unserviceable batteries and testing complete all as specified and directed |
| 44 | Material and labour for laying DWC (Double wall corrugated) pipe conforming or IS 16205 (electric cable use) of nominal outer dia 40mm and inner dia 32mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. Make : Universal /Rax/ Astrol |
| 45 | Supply and fixing in repair 3 mtr pole in tiranga colour comprising part I bottom section 114mmx1500mm, part II middle milky diffuser 120mm dia x 1500mm, MS Plate 200x200x12mm fitted with 30watt LED module in tiranga pattern (500mm saffron, 500mm white, 500mm green) pole section welded by certified welder using MIG process, provided with bottom service door in built connection box with gear tray, MCB and loop in loop out terminals, surface protected with epoxy zinc phosphate primer and PU paint finish excluding wire foundations bolt and other accessories ie. 04 Nos of M16x450 long J type EN 8 grade foundation bolts, tolerance +5. MAKE: orient/crompton/shakti lights/Halonix Please Enable Macros to View BoQ information |