| 1 | Notes applicable to all items of Schedule ‘A’ (BOQ) :- (i) Contractor shall check the equipments/ fittings/ fixtures etc as per the complaints given by the concerned JE E/M / Engineer-in-Charge. Contractor shall make arrangement for collection of complaint slip from MES service centre daily for carrying out the complaints & simultaneously intimate the JE E/M once the complaint is resolved. All complaints shall be resolved within 48 hours. (ii) In case contractor fails to resolve the complaint in 48 hours except where spare(s) is not readily available in the vicinity, a penalty of Rs. 100/- per day per complaint shall be deducted until the same is resolved. The decision of GE in this regard shall be final, conclusive & binding. (iii) If repair/maintenance of any equipment/ fitting/ fixture etc shall not be feasible at site/contractor’s store inside the cantt area and the same shall required to be taken outside the cantt area by the contractor, the same shall be taken outside of cantt area by the contractor only through proper Gate Pass duly signed by the Engineer-in-Charge. |
| 2 | Taking down carefully ceiling fans/ exhaust fans from any height and of any make and sweep including disconnecting the cable from ceiling rose and servicing, greasing & oiling, replacing the split pin, unserviceable nut, bolt, etc. and refixing the same after servicing with necessary connection complete all as specified and as directed. |
| 3 | Taking out carefully unserviceable shaft bush and S&F new shaft bush of existing type/ model for ceiling fans & exhaust fans complete all as specified and as directed. |
| 4 | Taking out carefully unserviceable ball bearing of any type/ size and S&F new ball bearing suitable for any type/ size ceiling fans & exhaust fans as per the existing standard complete all as specified and as directed. Make - SKF / TATA / NCB or as used by OEM and approved by GE. |
| 5 | Taking out existing unserviceable fan condenser/ capacitor of any size/ make and S&F connecting new fan condenser/ capacitor 2.0 to 2.5 mfd (ISI marked) complete all as specified and as directed. Make - Kail / Crompton / Tibcon / Epcos or as used by OEM and approved by GE. |
| 6 | Taking out existing unserviceable fan condenser/ capacitor of any size/ make and S&F connecting new fan condenser/ capacitor 3.15/ 4.0 mfd (ISI marked) complete all as specified and as directed. Make - Kail / Crompton / Tibcon / Epcos or as used by OEM and approved by GE. |
| 7 | S&F in repair modular step type fan regulator 100 W, 2 module, AC, 230V, electronic complete all as specified and as directed. Make: Legrand Cat No. 6755 30 or equivalent in makes mentioned in Appendix 'B' here-in-after. |
| 8 | S&F in repair step type fan regulator, AC, 230V, electronic on the existing phenolic laminated sheet etc complete all as specified and as directed. |
| 9 | S&F in repairs step type fan regulator 100W, 1 module, AC, 230V, electronic complete all as specified and directed. Make: Legrand Cat No. 6755 31 or equivalent in makes mentioned in Appendix 'B' here-in-after. |
| 10 | S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed. |
| 11 | Taking out carefully damaged/ worn out rubber reel from ceiling fan rod and S&F new rubber reel of existing size & shape complete all as specified and as directed. |
| 12 | Taking out carefully damaged/ worn out MS clamp and S&F new MS clamp with necessary nuts, bolts, washers, locking pins etc of existing size & shape complete all as specified and as directed. |
| 13 | Dismantling 1200mm sweep ceiling fan motor of any make, removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enamelled copper wire of adequate size/gauge including class B insulation, varnishing, heating etc, reassembling, testing, refixing and connecting complete all as specified and as directed. |
| 14 | All as per Item No. 12 here-in-above, but for 1400 mm sweep ceiling fan motor. |
| 15 | All as per Item No. 12 here-in-above, but for 400 mm sweep wall mounted fan motor. |
| 16 | All as per Item No. 12 here-in-above, but for 450 mm sweep exhaust fan motor. |
| 17 | All as per Item No. 12 here-in-above, but for 300 mm sweep exhaust fan motor. |
| 18 | All as per Item No. 12 here-in-above, but for 250 mm sweep exhaust fan motor. |
| 19 | All as per Item No. 12 here-in-above, but for 200 mm sweep exhaust fan motor. |
| 20 | Supply and testing wireless remote of brushless direct current (BLDC) ceiling fan of 1200/ 1400mm sweep as per existing make and model of fan installed on site complete all as directed. |
| 21 | S&F DO's/Don't instructions for Electric geysers as per E-in-C's branch letter instructions, printed on self adhesive plastic coated paper and shall be pasted on existing electric geysers complete all as directed. |
| 22 | Taking down geyser of any capacity, horizontal/ vertical type after properly disconnecting from water supply lines i.e. inlet/outlet and electric supply connections and re-connecting/ refixing the same in original position after necessary repairing work complete all as specified and as directed. Note: Repair works and Spare parts shall be measured and paid for separately. |
| 23 | S&F in repairs 3 core, 1 sqmm PVC insulated sheathed multistranded flexible copper conductor cable (ISI marked) 1100 Volts grade for fans etc complete all as specified and as directed. |
| 24 | S&F in repairs 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable (ISI marked) 1100 Volts grade for geyser complete all as specified and as directed. |
| 25 | S&F in repairs indicator lamp (Neon lamp) round / square in red / green / blue as required of standard make for geysers complete all as specified and as directed. |
| 26 | S&F in repairs thermostat switch for 50/25 ltr capacity geysers as per existing make/ model complete all as specified and as directed. |
| 27 | S&F in repairs heating element, 1000 W capacity and neoprene rubber washer, ISI marked for vertical/ horizontal type geysers of 50/25/10 litre capacity complete all as specified and as directed. |
| 28 | All as per Item No. 26 here-in-above, but heating element of 1500 W capacity. |
| 29 | All as per Item No. 26 here-in-above, but heating element of 2000 W capacity. |
| 30 | All as per Item No. 26 here-in-above, but heating element of 3000 W capacity. |
| 31 | S&F in repais 15mm dia PVC connection pipe, heavy duty of size 450 mm long with brass adopter/ union washer both sides suitable for hot water supply complete all as specified and as directed. |
| 32 | S&F in repairs 15mm dia Non Return Valve, lSl marked for vertical / horizontal geysers complete all as specified and as directed |
| 33 | S&F in repairs Plug Top 3 pin, 15/ 16 Amps capacity, lSl marked complete all as specified and as directed. |
| 34 | S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one Single Pole MCB 20 Amps, 10 kA, 'C' Curve complete all as specified and as directed. |
| 35 | M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed.Note :- 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable and casing and capping shall be measured as one run length for payment purpose. |
| 36 | S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed. |
| 37 | S&F in repairs flow unit/ syphon assembly including outlet and thermostat pipes with drain plug and screw for fixing the element inclusive of clamps for holding the element with nuts & bolts for geysers complete all as specified and as directed. |
| 38 | Taking down solar water heater of any capacity, horizontal/ vertical type after properly disconnecting from water supply lines i.e. inlet/ outlet and electric supply connections and reconnecting/ refixing the same in original position after repair complete all as specified and as directed. Note: Repair work and spare parts shall be measured and paid for separately. |
| 39 | M&L for servicing parts of TATA solar water heater of 100 Ltr capacity evacuated tube collector complete all as directed. |
| 40 | M&L for servicing parts of TATA solar water heater of 200/ 300 Ltr capacity evacuated tube collector complete all as directed. |
| 41 | M&L for servicing parts of TATA solar water heater of 100 / 300 Ltr capacity copper collector based chemical wash for collector complete all as directed. |
| 42 | S&F Silicon rubber, O ring with coupler set for 100/200 Ltr capacity solar water heater complete all as directed. |
| 43 | S&F in repairs 15mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement on walls/ceilings (concealed/surface) or laying in floors complete all as specified and as directed. |
| 44 | All as per Item No.42 here-in-above, but 20 mm outer dia pipe. |
| 45 | All as per Item No.42 here-in-above, but 25 mm outer dia pipe. |
| 46 | S&F in repairs Evacuated Solar Tube of minimum size 1800 mm x 58 mm complete all as specified. Make: Tata BP solar or equivalent make as approved by GE. |
| 47 | Dismantling & taking down old unserviceable/ rusted, worn out steel structure, brackets etc. from the roof or other locations complete all as directed.Note: Actual weight of steel shall be measured. Please Enable Macros to View BoQ information |
| 48 | Dismantling & taking down old unserviceable/ rusted, worn out steel structure, brackets etc. from the roof or other locations complete all as directed.Note: Actual weight of steel shall be measured. Please Enable Macros to View BoQ information |