| 1 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 2 | Dismantling chain link fencing any type complete all as specified and directed |
| 3 | Supply and fixing 3\\" x 3\\" ( 75 x 75mm) mesh size & 3.40 mm dia of wire chain link fencingn MS Galvanised complete including line wire, rails, straining bolts etc, including provision of binding wire complete all as specified and directed. |
| 4 | Dismantling Stone slabs floor, hearth or wall tiles of any description or thickness in floors, aprons etc including cement mortar bedding ( not backing coat) complete all as specified |
| 5 | M&L for 20mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6 |
| 6 | M&L for backing coats of 10mm thick in Cement mortar 1:3 on fair faces of brick work or concrete sur faces to receive the floor finished etc complete all as specified and directed |
| 7 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specifiied and directed by Engr-In-Charge. |
| 8 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specifiied and directed by Engr-In-Charge. |
| 9 | M&L for saw dust and sand in 1:2 ratio for filling spreading and leveling in layer n. exc 300mm thick and well ramming including watering as required complete all as specified and directed by Engr-In-Charge |
| 10 | Taing down cemment plaster on brick/concrete/stone surface of wall including racking out joints, hacking for key scrubbing down with water etc complete |
| 11 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement |
| 12 | M&L for preparing new plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 13 | M&L for preparing new plastered surface of wall and applying two coats of Oil bound distemper over a coat of primer complete all as specified and directed. |
| 14 | M&L for preparing old surface of brickor concrete surface of wall and applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete etc. |
| 15 | M&L for preparing old surface of brickor concrete surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete etc. |
| 16 | M&L for preparing Old plastered surface of wall and applying one coats of cement base complete all as specified and directed. |
| 17 | M&L for preparing old plastered surface of wall and applying one coats of Oil bound distemper complete all as specified and directed. |
| 18 | M&L for preparing old surface of brick/concrete/stone masonary surface of wall and applying two coats of white wash complete |
| 19 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 with grey cement and pigment complete and fixed in position |
| 20 | M&L for sand filling under floor as in sand cushioning layer below interlocking concrete paver block including watering and consolidation complete all as specified and directed |
| 21 | Demolition of un-reinforced cement concrete in ground floor paving n. exc 15 cm thick (below or above GL) complete all as speciifed and directed. |
| 22 | M&L for plain cement concrete 40mm thick type B-1, 1:2:4 (Using 20mm graded aggregate) as in floor finished even and smooth without using extra cement complete |
| 23 | M&L for plain cement concrete 1:4:8 type D-2 (Using 40 mm graded aggregate) as in Base/foundation etc complete |
| 24 | M&L for plain cement concrete 1:2:4 type B-0 (Using 12.50 mm graded aggregate) as in coopings/hold fast or 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed etc |
| 25 | Demolition of brick/masomary work built in CM or lime mortar including all quoins, arches, pillar etc complete all as specified and directed. |
| 26 | M&L for brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius and built in CM 1:6 |
| 27 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete |
| 28 | M&L for Mild steel including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 29 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complet |
| 30 | M&L for preparing new steel surface not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete |
| 31 | M&L for preparing old steel surface not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint etc complete |
| 32 | M&L for preparing new steel surface not otherwise described n. exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete |
| 33 | Demolition of re-inforced cement concrete of any description and in any position etc complete all as specified |
| 34 | M&L for Mild steel TMT/Round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 35 | M&L for Framed work such as grills, gratings,/monkey guard bar in PVC Tank et with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 36 | M&L for Mild steel screw bolts (machine made) with hexagonal or square of 10 to 12mm dia bolts heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n. exc 10 cm long with double bolts and washers complete all as specified and directed by Engr-In-Charge. |
| 37 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 38 | Dismantling of Asbestos cementGalvanume sheet/CGI Sheet/ Polycorbonate sheeting (corrugated, semicorrugated, etc.) sheets in roof covering etc complete all as specified and directed. |
| 39 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed |
| 40 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed |
| 41 | Fixing only Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. Note:- Item obtain from schedule no 8 to be fixed after cleaning and as directed by EIC. |
| 42 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri Please Enable Macros to View BoQ information |