| 1 | Creation of Sub Station of Various capacities from 25KVA to 630KVA alongwith allied material by way of Supply,Erection,Testing Commissioningetc of the following material: |
| 2 | 11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), Conforming to IS 1180 as per amendment No 4 of March-2021 and with LV Cable Box having detachable Aluminium Gland plate. |
| 3 | 63 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.) |
| 4 | 100 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.) |
| 5 | 250 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.) |
| 6 | 400 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.) |
| 7 | 11/0.433kV, 630 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound ) IS1180 part -1, 2014 as per latest modificatiosn and with LV Cable Box having detachable Aluminium Gland plate. |
| 8 | Construction of Concrete Platform for Transformer 400/630 KVA |
| 9 | Construction of Cement Platform with P.C.C 1:2:4 of Sizes(1500mm*1500mm*2000mm) with 20% Bolder. |
| 10 | Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type. |
| 11 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 12 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 13 | 50 mm² Single core XLPE cable,1.1K V Grade, Insulated Stranded Conductor FRLS type. |
| 14 | 70 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 15 | 95 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 16 | 120 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 17 | 185 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 18 | 240 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 19 | 400 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 20 | 630 mm² Cable,1.1KV Grade, XLPE Insulated Stranded Conductor FRLS type. |
| 21 | 9 Mtr. Long ST pole (ST-410 SP 33) |
| 22 | 9 Mtr. Long PCC pole (WL 300 KG) |
| 23 | 11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 24 | GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap |
| 25 | Galvanized Nuts and Bolts. |
| 26 | 3 Ph 4 Wire Trivector meter with CT/Prodogy Meter |
| 27 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 28 | Wedege connectors /PG clamps |
| 29 | Danger plate with clamps |
| 30 | GI Barbed wire for ani Clambing |
| 31 | Cement bottoming 1:2:4 mix as per REC standerds 0.5 Cum/pole |
| 32 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 33 | Red oxide |
| 34 | Aluminum Paint |
| 35 | Sundary items like Aluminium Lugs, Jumpers , binding tape |
| 36 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 37 | Dismantling of Sub Station of various capacities from 25KVA to 630KVA along with allied material |
| 38 | Dismantling of 11/0.433kV, 25 KVA, 3-phase Distribution Transformers |
| 39 | Dismantling of 63 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer |
| 40 | Dismantling of 100 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer |
| 41 | Dismantling of 250 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer |
| 42 | Dismantling of 400 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer |
| 43 | Dismantling of 11/0.433kV, 630 KVA, 3-phase Distribution Transformers |
| 44 | Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type. |
| 45 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 46 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 47 | 50 mm² Single core cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type. |
| 48 | 70 mm² Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 49 | 95 mm² Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 50 | 120 mm²Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 51 | 185 mm²Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 52 | 240 mm²Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 53 | 400 mm²Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 54 | 630 mm²Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type. |
| 55 | 9 Mtr. Long ST pole (ST-410 SP 33) |
| 56 | 9 Mtr. Long PCC pole (WL 300 KG) |
| 57 | 11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 58 | GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap |
| 59 | Galvanized Nuts and Bolts. |
| 60 | 3 Ph 4 Wire Trivector meter with CT |
| 61 | Wedege connectors /PG clamps |
| 62 | Danger plate with clamps |
| 63 | GI Barbed wire for ani Clambing |
| 64 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 65 | Sundary items like Aluminium Lugs, Jumpers , binding tape |
| 66 | Galvinised Stray Set |
| 67 | Erection of 25 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.). (DT Provided by the Deptt) |
| 68 | Erection of 63 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.). (DT Provided by the Deptt) |
| 69 | Erection of 100 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Coper Wound for 250 KVA or Higher KVA rattings.).(DT Provided by the Deptt) |
| 70 | Erection of 250 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.).(DT Provided by the Deptt) |
| 71 | Erection of 400 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.).(DT Provided by the Deptt) |
| 72 | Erection of 630 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound ) (Copper wound ) with Latest modificatiosn and with LV Cable Box having detachable Aluminium Gland plate..(DT Provided by the Deptt) |
| 73 | Laying of HT/LT line along with Conductor and allied material by way of supply,Erection,installation and commissioning etc: |
| 74 | 9 Mtr. Long pole (ST-410 SP 33) |
| 75 | 9 Mtr. Long PCC Pole(WL-300 Kg ) |
| 76 | 11 Mtr. Long pole (ST-410 SP 56) |
| 77 | 13 Mtr. Long pole (ST-410 SP 69) |
| 78 | 11 Mtrs.long PCC Poles (PCC WL-360 Kg) |
| 79 | 8Mtr. Long pole (ST-410 SP 15) |
| 80 | 8 Mtr. Long PCC Pole(WL-200 Kg ) |
| 81 | GI V cross-arm/Horizontal with top Bracket including clamp |
| 82 | GI Channel x-arm includingclaps and braces |
| 83 | 30 mm² ACSR Weasel Conductor |
| 84 | 50 mm² ACSR Rabbit Conductor |
| 85 | 100 mm² ACSR Dog Conductor |
| 86 | PG Clamps for ACSR weasel conductor |
| 87 | Anti Climbing Devices with clamps |
| 88 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
| 89 | Stone Pad (300mmx300 mmx75mm) |
| 90 | Aluminium Jointing Sleeves |
| 91 | GI U-Clamp for Shackle insulators |
| 92 | 16 KN Shackle insulators |
| 93 | Anti climbing Devices with Clamp |
| 94 | Aluminium Jointing Sleeves |
| 95 | LT line Spacers |
| 96 | Dismantaling of HT/LT line material along with conductor and allied material: |
| 97 | 9 Mtr. Long pole (ST-410 SP 33) |
| 98 | 9 Mtr. Long Pole(WL-300 Kg ) |
| 99 | 11 Mtr. Long pole (ST-410 SP 56) |
| 100 | 13 Mtr. Long pole (ST-410 SP 69) |
| 101 | 11 Mtrs.long PCC Poles (PCC WL-360 Kg) |
| 102 | 8Mtr. Long pole (ST-410 SP 15) |
| 103 | 8 Mtr. Long Pole(WL-200 Kg ) |
| 104 | GI V cross-arm/Horizontal with top Bracket including clamp |
| 105 | GI Channel x-arm including claps and braces |
| 106 | 30 mm² ACSR Weasel Conductor |
| 107 | 50 mm² ACSR Rabbit Conductor |
| 108 | 100 mm² ACSR Dog Conductor |
| 109 | PG Clamps for ACSR weasel conductor |
| 110 | Anti Climbing Devices with clamps |
| 111 | Aluminium Jointing Sleeves |
| 112 | GI U-Clamp for Shackle insulators |
| 113 | 16 KN Shackle insulators |
| 114 | Anti climbing Devices with Clamp |
| 115 | Aluminium Jointing Sleeves |
| 116 | LT line Spacers |
| 117 | Erection of poles & Conductors (Provided by the Department) |
| 118 | 9 Mtr. Long pole (ST-410 SP 33) |
| 119 | 9 Mtr. Long Pole(WL-300 Kg ) |
| 120 | 11 Mtr. Long pole (ST-410 SP 56) |
| 121 | 13 Mtr. Long pole (ST-410 SP 69) |
| 122 | 11 Mtrs.long PCC Poles (PCC WL-360 Kg) |
| 123 | 8Mtr. Long pole (ST-410 SP 15) |
| 124 | 8 Mtr. Long Pole(WL-200 Kg ) |
| 125 | 30 mm² ACSR Weasel Conductor |
| 126 | 50 mm² ACSR Rabbit Conductor |
| 127 | 100 mm² ACSR Dog Conductor |
| 128 | Supply and laying of HT/LT Cable |
| 129 | Supply and Laying of LT AB/XLPE Cable 35 mmsq 3.5Core |
| 130 | Supply and Laying of LT AB/XLPE Cable 50 mmsq 3.5Core |
| 131 | Supply and Laying of LT AB/XLPE Cable 95 mmsq 3.5Core |
| 132 | Supply and Laying of LT AB/XLPE Cable120sq mm 3.5Core |
| 133 | Supply and Laying of LT AB/XLPE Cable 185 mmsq 3.5Core |
| 134 | Supply &fixing of Heat Shrinkable Outdoor Kit forPVC Cables50sq mm |
| 135 | Supply &fixing of Heat Shrinkable Outdoor Kit forPVC Cables120sq mm |
| 136 | Supply &fixing of Heat Shrinkable Outdoor Kit for S/CPVC Cables 185sq mm |
| 137 | Supplying and Fixing of Mid Span Straight Jointing Kit for LT ABCables 185 mm² |
| 138 | Supplying and Fixing of Mid Span Straight Jointing Kit for LT ABCables 120 mm² |
| 139 | Supplying and Fixing of Mid Span Straight Jointing Kit for LT ABCables 50mm² |
| 140 | Supply and Laying of HT AB/XLPE Cable 50 mmsq 3Core |
| 141 | Supply and Laying of HT AB/XLPE Cable 120 mmsq 3Core |
| 142 | Supply and Laying HT AB/XLPE Cable 185mmsq 3Core |
| 143 | Supply &erection of Heat Shrinkable Outdoor Kit for HTAB/XLPECables 185mmsq |
| 144 | Supply &erection of Heat Shrinkable Outdoor Kit for HTAB/XLPECables 120mmsq |
| 145 | Supply &erection of Heat Shrinkable Outdoor Kit for HTAB/XLPECables 50mmsq |
| 146 | Supply and Fixing of Mid Span Straight Jointer Kit for HT cables 185mmsq |
| 147 | Supply and Fixing of Mid Span Straight Jointer Kit for HT cables 120mmsq |
| 148 | Supply and Fixing of Mid Span Straight Jointer Kit for HT cables 50mmsq |
| 149 | Supply & Fixing of Suspension clmps for HTABCables |
| 150 | Supply & Fixing of Anchoring Clampsfor HT ABCables |
| 151 | Providing & fixing of jumper on 11kv line with ACSR Dog |
| 152 | Providing & fixing of jumper on 11kv line With ACSR Rabbit |
| 153 | Providing & fixing of jumper on 11kv line with ACSR Weasel |
| 154 | Providing & fixing of Jumpers with ACSR Dog |
| 155 | Providing & fixing of Jumpers with ACSR Rabbit |
| 156 | Providing & fixing of Jumpers with ACSR Weasel |
| 157 | Providing & fixing of Jumpers with ACSRSquirrel |
| 158 | Providing & fixing of shackle insulator. |
| 159 | Dismantling of HT/LT Cables |
| 160 | LT AB/XLPE Cable 50 mmsq |
| 161 | LT AB/XLPE Cable 95 mmsq |
| 162 | LT AB/XLPE Cable120sq mm |
| 163 | LT AB/XLPE Cable 185 mmsq |
| 164 | Heat Shrinkable Outdoor Kit forPVC Cables50sq mm |
| 165 | Heat Shrinkable Outdoor Kit forPVC Cables120sq mm |
| 166 | Shrinkable Outdoor Kit for S/CPVC Cables 185sq mm |
| 167 | Mid Span Straight Jointer Kit for LT ABCables 185 mm² |
| 168 | Mid Span Straight Jointer Kit for LT ABCables 120 mm² |
| 169 | Mid Span Straight Jointer Kit for LT ABCables 50mm² |
| 170 | HT AB/XLPE Cable 50 mmsq 3Core |
| 171 | HT AB/XLPE Cable 120 mmsq 3Core |
| 172 | HT AB/XLPE Cable 185mmsq 3Core |
| 173 | Heat Shrinkable Outdoor Kit for HTAB/XLPECables 185mmsq |
| 174 | Heat Shrinkable Outdoor Kit for HTAB/XLPECables 120mmsq |
| 175 | Heat Shrinkable Outdoor Kit for HTAB/XLPECables 50mmsq |
| 176 | Mid Span Straight Jointer Kit for HT cables 185mmsq |
| 177 | Mid Span Straight Jointer Kit for HT cables 120mmsq |
| 178 | Mid Span Straight Jointing Kit for HT cables 50mmsq |
| 179 | Suspension clmps for HTABCables |
| 180 | Anchoring Clampsfor HT ABCables |
| 181 | jumper on 11kv line with ACSR Dog |
| 182 | jumper on 11kv line With ACSR Rabbit |
| 183 | jumper on 11kv line with ACSR Weasel |
| 184 | Jumpers with ACSR Dog |
| 185 | Jumpers with ACSR Rabbit |
| 186 | Jumpers with ACSR Weasel |
| 187 | Jumpers with ACSRSquirrel |
| 188 | Shackle insulator. |
| 189 | Installation of Street Light (LED Bulb) of 36Watt(Complete Job) |
| 190 | Installation of 11KV HT metering CT and PT unit on Turnkey Basis by way of supply Erection,Testing Commissioning et of following Material: |
| 191 | Providing/Erection of 11KV HT Metering CT and PT unit(Complete Job) Please Enable Macros to View BoQ information |