| 1 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead asper direction of Engineer-in-Charge. DSR 2023 16.83 (RATE-131.75) |
| 2 | laying of Granular Sub-Base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 By Mix in Place Method |
| 3 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). 30% EXISTING TILES DSR 2023 (RATE - 402.95) |
| 4 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.. DSR 2023 16.91.2 (RATE-1091.50) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 4.1.8 (RATE-6812.00) |
| 6 | Brick work with class 150 bricks of designation 15 in foundation and plinth in: cement mortar 1:4(1 cement :4 coarse sand )(as per DAR) OR DSR S.I NO. 6.1.1/2023 |
| 7 | Brick work with class 150 bricks of designation 15 in superstructure above plinth level up to floor 5th level in all shapes and sizes in :cement mortar 1:4(1 cement :4 coarse sand )(as per DAR) OR DSR S.I NO. 6.4.1/2023 |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)DSR 2023 5.3 (RATE-11505.50) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR 5.22A.6 |
| 10 | 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) DSR 2023 13.4.1 (RATE-357.35) |
| 11 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR2023/10.31 (RATE-130.50) |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR 2023 13.80(RATE-156.05) |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR2023/13.46.1(RATE-160.60) |
| 14 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm :DSR2023/13.48.1(RATE-193.70) |
| 15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm DSR 2023 11.41.2 (RATE-1553.45) |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps anddados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.DSR 2023 8.31(RATE-1267.95) |
| 17 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter DSR No. 12.41.2,2023 (RATE-377.40) |
| 18 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured DSR No. 22.6,2023(RATE-688.90) |
| 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in hasic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm). DSR No. 21.3.1,2023 (RATE-1176.80) |
| 20 | Providing and fixing wash basin with C.I. brackets, 16 mm C.P. brass pillar taps, 32 mm C.P, brass waste of standard pattern, including painting of fillings and brackets, culling and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. DSR No. 17.7.1 2023 (RATE-2648.85) |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes DSR No. 18.7.1 2023(RATE-286.80) |
| 22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wall 25 mm nominal dia Pipes DSR No. 18.7.3 2023(RATE-401.55) |
| 23 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern. DSR No. 17.4.1 2023(RATE-6258.75) |
| 24 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushin cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests .DSR 2023 17.1.1(RATE- 6767.40) |
| 25 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flus bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lidDSR 2023 17.3.1 (RATE-8006.60) |
| 26 | Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms15 mm nominal bore.DSR 2023 18.51.1(RATE-798.95) |
| 27 | Providing and fixing C.P. brass stop cock (concealed) of standard designand of approved make conforming to IS:8931. 15 mm nominal bore. SOR 18.52.1(RATE-670.45). |
| 28 | Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931 15 mm nominal bore.DSR 2023 18.53.1(RATE-574.30) |
| 29 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed towooden cleats with C.P. brass screws and washers complete. DSR 2023 17.31 (RATE-1607.95) |
| 30 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.DSR 2023 18.48 (RATE-11.00) |
| 31 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete 32 mm dia.DSR 2023 17.28.2.1(RATE-119.55) |
| 32 | ELECTICAL WORK (PART-B)Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRIS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B DSR 2022 (1.10.2)(RATE-1182) |
| 33 | Supplying and fixing suitable size GI box with modular plate nad cover in front on Surface or in recess, including providing and fixing 6 pin 5/6 & 15/16A Module Socket outlet and 15/16A modular switch, connections etc, as required, DSR 2022(1.32) |
| 34 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2x2.5+ sqmm +1x2.5 sqmm earth wire DSR 2022 (1.14.2) |
| 35 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2x2.5+ sqmm +1x2.5 sqmm earth wire DSR 2022 (1.14.2) Please Enable Macros to View BoQ information |