| 1 | Supply of 300 Sqmm 3 Core high conductlvty alumlnlum stand compacted clrcular conductor XLPE armored 33 kv cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I AOR Make:- Grandley/Gloster/Havells/ Dicabs/ Polycab/KEI-3 core, 300 Sq, mm, 33kv |
| 2 | Supply of flowing type hlgh conductivity aluminlum standcompacted circular conductor XLPE armored 11 kv cable neutral earthed system conferming to with latest amendment at a depth of 900 mm. below ground level over a cushion of 100mm thick sand around and protect with brick on sldes and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all meterial labour t&petc. required for proper completion of the work complete in all respect, uprc-p.no.-47Make:- Grandley/Gloster/Havells/ Dicabs/ Polycab/KEI-3 core, 185 Sq, mm, 11kv |
| 3 | Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 10.00 Nos in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 4 | Supply of Top MS channel 100x50x2240mm aa per design 23.00 Nos complete in all respects UPERC P-39 |
| 5 | Supplying of channel iron 100 mm x 50 mm x6 mm (9.56 kg per metre) pole top bracket/ cross arm for single 33 KV over head line conductor complete with 50 mm x 6 mm M.S flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint asl required. DSR 2018, 13.18 |
| 6 | SUpplying and erection of 33 KV pin insulator complete with large steel head G.l. pin, nuts, washers etc. as required...(DSR Electrical |2018/item 13.23 page 50) |
| 7 | S/Making of straight through joint suitable for 300 sq. mm x 3crore 33KV armoured cable as per ISS & complete in all respect Make: Raychem, Denson, Cabseal. As per direction of E/. (UPERC|P-47) |
| 8 | S/F OF 6\\" Dia G.l pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt nuts and washer required for proper completion of work (UPERC P-47) |
| 9 | S/E of over head line with ACSR Panther Conductor on pole/service braket including binding etc. Completein all respects as per PS NO.627 |
| 10 | Supply and burrtng of safe Erthing tlectode 1-19 (Hot DinGavanlzed), Length up to 3000 m, Outer bi 50 mm, nnet Dl25, terminal Dla 12 mm, outer Gl plpe of 16 swg and inner Gl plpe of 12 swg with Hot Dip Galvanleetlon up to 100 mieron lted with crystalline conductlve mbeture (CCM) havlng antt eoresve & Jconductve property wlth 50 kgs actvated sl (0FC) capable of reduclng the soll reslstlvity with food mixture of retalntng Jcapacity ene earth lead of 25 mm x a mm G.l, Strip up to switch board (from apron to swtch board, the cost of G.. strlp will be extra.) along with 30 cm squrare C. frame with hinged cover masonry housng ps 725 (B) |
| 11 | Palntlng of the electrlc pole with 2 coat of AI palnt over rod oxldeprtner cormplete in all respects as per PS NO. 634 |
| 12 | SAaying of heavy denslty poly ethylene plpes ISI marked ant rediant grade OD 160 mm dia PN-8 PE 100 (PE 400) grade as perl IS code 4984 with excavation at deapth of 1.20 Mtr below ground level Vc the cost of cutting of plpes for maklng up to length and making jolnts complete all respects as per dlrectlon of E/ (AOR)Make:- Rex/Duraline/Time/CPE |
| 13 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) of slze 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm Including Inscriptlon |duly engraved as required..DSR elect 2018 ltem.N. 7.9/P30 |
| 14 | Laying of one number PVC nsulated and PVC sheathed/XLPE power cable of 11 kv grade of upto 120 sq. mm. to 400 sq. mm slze direct in ground Including excavation, sand cushioning.protective covering and refilling the trench etc. as required. (DSR-2018) 8.1, P-31 above 120 sq. mm. upto 400 sq. mm |
| 15 | S/F of jointing of 185 sq. mm. outdoor/indoor type 11 KV Jointing kit heat shrinkable type for 11 KV cable including cost of allmaterial, labour, T & P etc. for proper completion of the E/.(Raychem/Denson/Make) outdoor type. (UPERC) P-41 |
| 16 | Supply and fixing of following type plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer- Incharge. UPPWD-2019 185 sq. mm. |
| 17 | Supply and laying of 32 mm x 6 mm G.l. strip from earthelectrode directly in the ground as required complete in alrespect. PS NO, 717 |
| 18 | Laying of one number additional XLPE power cable of 33 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. .( DSR elect 2018 item.N, 8.6.2/P31) Above 120 sq.mm and upto 400 sq. mm |
| 19 | S/F of jointing of 300 sg.mm out door type 33 KV jointing kit heat shrinkable type for 33 KV Cable including cost of all materlal, labour,T&P etc. for proper completion Make |Raychem/Denson/Capseal as per direction of E/. (UPERC P-47 |
| 20 | supply & fixing of jointing of following sizes outdoor/indoor type 11 kv Jointing kit heat shrinkable type for 11kv cable including cost of all materlal, labour, t&p etc for proper completlon of the E/ complete in all respect.-185 Sq. mm. x3 core, 11kv UPER-PN-41 |
| 21 | Providing and laylng of 200mm d Bmm thickness through tranchles method Including Jolntng of plpe excavatlon of thrust plt and recelving plt of requlred stze cuttlng and reparlng of roadwith all T&P and the GPS report submlted by the tenderer before excavatlon & back flng with compactlon complete os perspecificatlon by H.O.D. machlne method plpe wll be Installed at minimum depth 2m to 3 m below the ground urtace or downward as per slte condltlon In requlred slope AOR |
| 22 | Supply of 2.4 Mtrt LED Decoratlve pole made of square plpe duly CNC cut llumlnated customlsed deslgn fltted with Led module and Acrylc/ PC, 50 watt CNC cut portlon and 4 x 25 watt LED Moudled on Top. Plpe dia 200 x 200 x 4 mm, base plate 300 x 300 10mm (Total wattage of 150 watt) AOR Make:- VAK/Mayfair/ k lite /Kesslec/Neri/ Ligman |
| 23 | Supply and installation of LED Column light made of mild steel with fine laser cut design and signage of NOIDA Authority logo closed by diffuser and have ingress protection for optical compartment. Fitting is tailored with lighting to suit your specific requirement with height S mtr above ground level with mid light illumination of 120W. The column section shall be of 600mmx600mm with top part predesigned of Noida Authority LOGO. Midsection gives the homogeneous light output. All pole section Shall be welded by certified welders using high and MIG welding process. The Service door shall be provided at bottom part of the pole which equipped with a C clamp with sliding nuts to accommodate a built in connection box.The control gear tray is prewired with MCB, terminal connectors for loop in loop out arrangement. The base plate of the pole is design with elongated foundation holes for fine alignment of the pole during installation. Nano Ceramic surface conversion, resistant to corrosive environment. Fitting is made of mild steel with fine laser cut design and signage closed by diffuser tailored with lighting to suit your specific needs as per detail drawing.Color tolerance ,3 SCDM to avoid color deviation. Nano Ceramic surface conversion, resistant to corrosive |
| 24 | Environment. Luminaire primarily coated with epoxy resin and top coated with UV stabilized MRF PU PAINT or powder coated and cured. All exterior parts are made of stainless steel.Fitting is coated with epoxy zinc phosphate primer and niched using environmentally stable PU paint. Diffused symmetric light without glare. Light output of source is more than 1101m/ watt, CRI>70, Surge protection 10k, operating voltage 140-270V, wired with Branded LEDs of Osram/ Cree and Fulham or equivalent constant voltage/current driver with efficiency> 80%, power factor»0.9, THD<=10%. The CCT of led will be 3000k as required by the project. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. as approved by engineer in charge and consultant Total Rs. (Incl. of All Taxes) Make:- VAK/Mayfair/ k lite /Kesslec/Neri/ Ligman |
| 25 | Supply and installation of decorative Column light in 3000mm height suitable for 60W LED, IP65 in 3000k. Column light made of GI sheet and have height 2.5mtr above ground level with three spot light of 20W each for area Illumination and column with top predesigned laser cut to illuminate the surroundings with noticeable mode. The column light pole section of 220mmx220mm x 4mm thickness up to 2.5mtr long with three illuminated portion of 600mm each. The base plate dimension is 209x209x10mm. The control gear tray is prewired with MCB, terminal connectors for loop in loop out arrangement. Luminaire primarily coated with epoxy resin and top coated with powder coat. All exterior parts are made of stainless steel. |
| 26 | Light output of source is more than 110lm/ watt, CRI>70, Surge protection 4k, operating voltage 140 270V, wired with Branded LEDs and driver with efficiency> 86%, power factor>0.9, THD<=10%. The CCT of led will be 3000/4000/5000 as required by the project. Proper thermal management for longer life of fixture.Led burning of 60,000 hours. Fitting is complete in all aspects with all accessories except foundation bolt AOR Make:- VAK/Mayfair/ k lite /Kesslec/Neri/ Ligman |
| 27 | Erection of metallic pole of following length in cement concrete1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 40mm nominal etc, as required,-Above 4.5 metre and upto 6.5 metre DSR 11.3.1 |
| 28 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheated cable 1100 volts grade at a depth of 750mm, below ground level over a cushion of 75mm, Thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc, of suitable size or as directed by the Engineer-incharge, complete in all respect, the armouring of the cable shall be properly connected with the earth conductor by clamps etc. Make:- Grandley/Gloster/ Havells/Plaza/ Dicabs/KEI -10sq.mm. x2 core |
| 29 | 16 sq, mm x4 core |
| 30 | 70 sq, mm. 3.5 core |
| 31 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PSN0.504-10 sq.mm. |
| 32 | 16 sq.mm. |
| 33 | 70 sq.mm. |
| 34 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc, conforming to is 14930, Part ll complete with fitting and cutting, jointing etc. direct In ground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.,Make:- Rex/Duraline/Time/CPE complete as required, DSR 14.16 -63 mm dia (0D-63 mm & ID-51 mm nominal) DSR.14.16.1 |
| 35 | 90mm dia (OD-90m & ID-76mm nominal) DSA 14.16.2 |
| 36 | supply end fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid 2 proof paint consisting of time switch ISO 100 series with contactor, NRC fuses, isolating switch metering instrument & instruments box with CTs etc, In case of TPN, complete in al respect 25 A TPN UPPWD SOR 2018 Item no. (807 (le) i) electrical |
| 37 | supply and buying of 600mm x 60Omm x 6mm G.l. plate vertically for earthling with its top at lest 3 meters below ground level complete with 20mm dia G.l. pipe funnel for watering and on earthling lead of one no, 8 to 10 SWG GI wire in 15mm dia G.l. pipe up to switch board (from apron to switch board the cost ofl G.l. pipe and G.l. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke land salt at least 15Omm thick around etc, as per direction of engineer-in-charge complete in all respect as per drawing (This will apply for earthling of poles also). UPPWD SOR-2018 item no. (702)Electrical. |
| 38 | Dismantling of over head lines comprising of copper/aluminum overhead conductor, G.l. wire, cross arms, insulators etc, as required, DSR 12.40 |
| 39 | Dismantling of pole/street light standard/ strut embedded in cement concrete foundation etc, as required. DSR 12.42 |
| 40 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) (Bituminous Portion) 39 |
| 41 | Water Bound Macadam |
| 42 | Demolishing cement concrete manually by machanical meanslincluding disposal of material within 50 mtr lead as per direction of Engineer-in-charge, Nominal concerte 1:3:6 or richer mix (/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 43 | Cement concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of alll materials, labours, tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.NO. 5.07/S.N.279 |
| 44 | Cement concrete with 4 cm gauge approved stone & cement in the proportion of 8:4:1 including supply of all materials, labours, tools & plants etc. required for proper completion of the work. (SOR, UPLNV, LNO. 5.08/S.N. 281) |
| 45 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable materlal to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/ AOR |
| 46 | Laying old cement concrete Interkocking paver blocks of any Jdesign/shape lald in requlred line, level curratlve colaur andpattren over and Including 50 mm thlck compacted bed of coutrse sand flling the Jolnt with fine sand etc. all complete as pet directlon of EA (Old CC Paver block shall be suppled by the deptt free of cost) (AOR) |
| 47 | Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/1. (AOR) |
| 48 | supply & fixing of LED Strip 5 w/m with life L 70/40000 boring hours of reputed LED make saffran/white/green datachable in 1 m suitable for 24Ov AC 30m of strip for out door use with 3 years warranty, complete in all respects as per direction o E/ AOR |
| 49 | Supply and fixing danger board fabricated from 10 gauge M.S. sheet as per l.E. Rules PS N0. 1109 Please Enable Macros to View BoQ information |