| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Item No.1 Repairs to 215 HP V.T. Pump Set No. at Uhethan Jackwell |
| 3 | Item No.2 Rewinding of 215 HP VHS Motor AND Repairs And Servising Of VHS Motors At Jackwell Uchethan |
| 4 | Item No.3 Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCBDSR Rate 25327 + 5% = 26593.35 |
| 5 | Item No.4 Providing And Erecting Bottom Ball Bearing No.6318 2Z/C3 |
| 6 | Item No.5 Providing, installing triple pole over current and earthfault relay, 3 O/C and 1 E / F with high set over current setting , -50% to -200% of 5 Amp . Earth fault setting , 10% to 40 % of 5 Amp |
| 7 | Item No.6 Supplying and erecting air circuit breaker manually operated drawout type of 1250A rated at 50º C without deration, 500V, 3 pole having short circuit rating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frame as per specification no.. SW-SWR/ACBDSR RATE 168448 + 5% = 176870.40 |
| 8 | Item No.7 Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.DSR Rate 15900 + 5% = 16695 |
| 9 | Item No.8 Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm.DSR Rate 6340 + 5% = 6657 |
| 10 | Item No.9 Supplying and erecting 11 kV fuse barrel with metal fittings completeDSR Rate 448 + 5% = 470.4 |
| 11 | Item No. 10 Supplying heavy duty operating rod, outer dia 25 mm & inner dia 20 mm suitable for 11 kV with brass couplings etc. for removing drop out fuses at 6 meters length, 4 pieces each with rain shade with hand grip including earthling chain 1.5m complete.DSR Rate 4590 + 5% = 4819.50 |
| 12 | Item No. 11 Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete.DSR Rate 202 + 5% = 212.10 |
| 13 | Item No. 12 Supplying and erecting bank of All Polypropylene capacitors with the standard capacities of 1,2, 3, 5, 7, 12.5, 15, 20 and 25 KVAR units of power factor correction for operation on 3phase, 50 Hz, 400 V+/- 10% with externally discharging resistances, earthing terminals and built on angle iron or KVAR 376 32 408 channel iron frame work and provided with terminal cover box complete erected and tested. |
| 14 | Item No. 13 Repairs to 60 HP V.T. Pump Set No.2 at Bhose WTP |
| 15 | Item No. 14 Rewinding Of 60 HP VHS Motor with minor repairs ETC |
| 16 | Item No. 15 Rewinding of submersible pump motor in Borewell of all types and makes above 5 H.P. up to 25 H.P with coated copper wires & overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed, H.P. and no load consumption & guarantee for one year.DSR Rate 1871 + 5% = 1964.55 |
| 17 | Item No. 16 Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. |
| 18 | Item No. 17 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges,unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI &GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) |
| 19 | Item No. 18 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CUDSR Rate 863 + 5% = 906.15 |
| 20 | Item No. 19 FOR GATE VALVE CONNECTION : Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineerin-charge including cutting, fabricating,hoisting,erecting, fixing in position,making riveted / bolted / welded connections and one coat of anti corrosive paint and over it two coats of oil painting,etc. complete.(Bd-C-3/275) |
| 21 | Item No. 20 150 mm @ Bhuyar MBR, 200 mm@ WTP , Redde MBR & Bhuyar MBR , And 250 mm@ WTP, Redde MBR & Bhuyar MBR, 300 mm @ Gonewadi MBR & 350 mm @ Redde MBR Sluice Valve Servicing , Cleaning |
| 22 | GST 18 % Please Enable Macros to View BoQ information |