| 1 | Excavation in foundation in ordinary soil (Loam, Clay or Sand) Including lift upto 1.50 m and lead upto 30m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation |
| 2 | Providing and laying cement concrete in 1:6:12 (1 Cement : 6 Coarse sand : 12 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. in Foundation and floors. (DAR-273) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | 6mm Celling plaster 1:3 (1 cement : 3 fine sand) cement & fine sand in F.M. not less than 1.25, 1:3 including chiping of RCC surface before ceiling plaster. The cost of including all material, labour T&P and scafolding etc. complete. (DAR-13.16) |
| 5 | Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade on undacorated wall surface to give even shade over @ 1.25 Ltr/10sqm including one coat of primer applid @ 0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required for proper completion of work.for two coat. (Chapter_15_Item_35 agra 2020) |
| 6 | 12mm Cement plaster with cement mortar in proportion of 1:4 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm. In girth and finished even and |
| 7 | Supply and hoisting of Sintex or equivalent high density polyethylene seamless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tank should be ISI marked, Sintex or equivalent. (c ) For 1000 litres. (Chapter_19_Item_2C |
| 8 | Dismentlng existing plaster including disposal of refuse as directed by ingineer-in-chargewith distence of 60 meter (200 feet) |
| 9 | Supply and fixing 10 cm. dia C.P jali complete in all respect as per directed LMR |
| 10 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over & including water thinnable priming coat with cement primer including cost of all materials labour T&P etc. required for proper completion of work.(Chapter_15_Item_7) |
| 11 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface(Old) |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (13.80) |
| 13 | Supply and fixing of soap dish complete in all respect as per direted LMR (138x120x75)mm (7509-2021mat) |
| 14 | Painting two coat over old surface on steel and other metals surface brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matters sand papering and scraping including cost of all materials, labor and T&P etc. for proper completion of the work. 643x2 ver previously painted surface |
| 15 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 16 | Providing and fixing on wall face unplasticised Rigid PVC 110 mm rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade accordingto IS: 1868, Minimum anodic coating of grade AC 15)(Chapter_21_Item_1) |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade accordingto IS: 1868, Minimum anodic coating of grade AC 15)(Chapter_21_Item_1) |
| 18 | Dismentaling brick work or stone work in lime or cement mortar and including stacking of materials as directed by Engineer-In-Charge within a distance of 50 meters (200 feet) |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 21 | Supply and fixing of 100 mm nihani trap PVC completed in all respect as per directed LMR |
| 22 | 40 mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate of size 20 mm and below) laid in panels finished with floating coat of neat cement and stone dust in 5:1 ratio without base concrete but Excluding cost of glass strips (SI. 4.1.3) |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level With 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 24 | Providing and fixing of C.P. brass towel rail 750x20mm together with pair of C.P. brass brackets to fit the towel rail. (Chapter_ 22 _Item _32) |
| 25 | Providing of fixing toilet paper holder 17.34.1 CP brass LMR |
| 26 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore ( Chapter_20_Item_18 |
| 27 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (15mm nominal bore )CH-20 Si No- 16 |
| 28 | Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per (Cost of aluminium snap beading shall be paid in basic item): ii) With float glass panes of 5.5 mm thickness (Chapter_9_Item_8B) |
| 30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 120 mm thick cement mortar 1:3 (1 Cement : 3 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (Chapter_13_Item_8) |
| 31 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm (Chapter_ 24 _Item _23b) |
| 32 | Providing and laying Vitrified tiles in floor without lean concrete of 600x600mm sizes (thickness 10mm), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, including grouting of joints. (Chapter_13_Item_13) |
| 33 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm (Chapter_11_Item_2) |
| 34 | Supply and filling of 40mm first class brick bats of sockpit. |
| 35 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (Chapter_19_Item_1) |
| 36 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single of 15 mm C. P. brasspillar taps ( Chapter_19_Item_5) |
| 37 | Black granite Polished stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Black Granite Stone quality (Chapter_14_Item_9) |
| 38 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal with 5 litre PVC. automatic flushing cistern (Chapter_19_Item_2A) |
| 39 | Mild steel or iron in plain work such as reinforced cement concrete or reinforced brick work (when not included in an overall rates), wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bends, hooks and authorized overlapping shall be measured upto floor two level. (SI NO 504) |
| 40 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. (DAR-6.1.1) |
| 41 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage .for all leads; but excluding the cost of centering, shuttering, finishing and inforcement as per direction of the engineer-in-charge, for the following grades of concrete.RCC WORK IN RAFT FOUNDATION |
| 42 | Class-150 (Non Modular) brick work in 1:6 cement and Coarse sand mortar in super Structure wall including supply of all materials, labour and T&P etc. required for proper completion of the work. DAR-6.4.2 |
| 43 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregateand fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; includingpumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per directionof the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement.(4.20.2.10) |
| 44 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement |
| 45 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 46 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid (Chapter_19_Item_18) Please Enable Macros to View BoQ information |