| 1 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces all as specified and directed. |
| 2 | M&L for preparation of new/old treated surface MS roof sheet of any description and in any position of 10 cm girth or width applying one coat of anit corrosive synthetic enamel/coptic green paint complete all as specified. |
| 3 | M&L for pre-cast cement concrete block masonry (1:3:6), type C-1 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed. |
| 4 | M&L for rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing with ceent plaster 1:4 all as specified. |
| 5 | M&L for preparing surface plastered or unplastered new surfaaceon walls and applying two coats of cement based paint all as specified. |
| 6 | Excavatingin trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable, foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil including forming bottom surface to required level or slope, complete all as specified and directed. |
| 7 | Excavatingin trenches, n exc 1.5 m wide and exc 1.5 m in depth and n exc 3.0 m depth; for laying of cable, foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and and getting out in soft/ loose soil including forming bottom surface to required level or slope, complete all as specified and directed. |
| 8 | Returning filling in hard/dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed |
| 9 | Removal of surplus excavated (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed. |
| 10 | M&L for plain cement concrete (1:2:4), type B-1 (using 20 mm graded stone aggregates) as in foundation, filling and mass concrete including necessary form work for rough finished surface, complete all as specified and directed. |
| 11 | Material and labour for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation/ coping of poles including use of necessary form works for rough finished surface complete all as spd. |
| 12 | Dismantling/Taking out of old Unsv HT cable from any location complete along with earth work manually with out damaging of the HT cable and making the surface good all as specified and directed by Engr in Charge.Note: Earth work will be common for both removal an laying new cable in same route |
| 13 | Re laying, jointing, testing and commissioning existing HT XLPE cable cross sectional area of any size removed from item no 01 and re laying in DWC pipe / ducts / trenches, under floor and road or fixed to wall etc complete all as specified and directed. |
| 14 | Supply, laying, jointing, testing and commissioning HT XLPE cable cross sectional area 95 Sqmm 3 core, 11000 volt screened, PVC bedded \\"Earthed grade\\" insulated bedded, galvanized steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system conforming to IS-7098 (Part-I) 1977 and Part-II of 1985 laid in pipe / ducts / trenches, under floor and road or fixed to wall etc complete all as specified and directed. |
| 15 | Supplyand laying DWC pipe SN-8 with coupler 75 mm OD,ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. laid in trenches/ fixed to pole /laying under road crossing/fixed on pavement walls with clamps complete all as specified and as directed. |
| 16 | M&L in replacement of end terminal joints kits cold shrinkable suitable for HT 11000 V (Earthed), XLPE insulated armoured heavy duty under ground cable including joint kits complete for making joints suitable for aluminium conductor cable of cross sectiona larea 95 Sqmm, 3 core, complete all as specified and directed. |
| 17 | M&L in replacement of straight through heat shrinkable suitable for HT 11000 V (Earthed), XLPE insulated armoured heavy duty under ground cable including joint kits complete for making joints suitable for aluminium conductor cable of cross sectiona larea 95 Sqmm, 3 core, complete all as specified and directed. |
| 18 | M & L cable Jointing Kit for 11 KV ( Earthed) grade cable for Indoor termination cold shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE Armoured aluminium cable of size 95 Sqmm complete all as directed by Engr-in-Charge. |
| 19 | M & L cable Jointing Kit for 11 KV (Earthed) grade cable for Outoor termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE Armoured aluminium cable of size 95 Sqmm complete all as directed by Engr-in-Charge. |
| 20 | Taking out Trolley of Vaccum circuit breaker Make : Schneider Model : HWX and Make : Areva Model : VMX, 11 KV VCB of rating 630 Amp from the cubical and including opening top cover, de-carbonizing moving and fixed contacts if required, lubricating, inspecting the wiring of microprocessor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system and placing back the breaker trolley in its original position and checking of VCB panel, HT cable connection, busbar connection, replacement of worn out nut and bolts, checking/repairing internal wiring system complete, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, controll limit switches reconnecting of the breaker for smooth functioning all as directed complete testing and commissioning. Ensure proper functioning. Please Enable Macros to View BoQ information |
| 21 | Taking out Trolley of Vaccum circuit breaker Make : Schneider Model : HWX and Make : Areva Model : VMX, 11 KV VCB of rating 630 Amp from the cubical and including opening top cover, de-carbonizing moving and fixed contacts if required, lubricating, inspecting the wiring of microprocessor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system and placing back the breaker trolley in its original position and checking of VCB panel, HT cable connection, busbar connection, replacement of worn out nut and bolts, checking/repairing internal wiring system complete, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, controll limit switches reconnecting of the breaker for smooth functioning all as directed complete testing and commissioning. Ensure proper functioning. Please Enable Macros to View BoQ information |