| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtrs in depth for laying of cables including getting out in hard and dense of soil complete all as specified and directed. |
| 2 | All as per item No - 01 here in before but exc 1.5 mtr in depth and n. exc 3.0 mtr in depth complete all as specified and directed by Engr- in- Charge. |
| 3 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 4 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed by Engineer-in-Charge. |
| 5 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. |
| 6 | Supply and laying sub class 'B' bricks of (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 7 | Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminum conductor, 1100 volts grade of cross sectional area 16 Sq mm 04 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule. |
| 8 | All as per item No. 7 here-in-before but of size 25 Sqmm 4 core |
| 9 | All as per item No. 7 here-in-before but of size 35 Sqmm 3.5 core |
| 10 | All as per item No. 7 here-in-before but of size 50 Sqmm 3.5 core |
| 11 | All as per item No. 7 here-in-before but of size 150 Sqmm 3.5 core |
| 12 | Dismantling and taking out old UNSV LT cable of any size, any make and any type from trenches with brick protection complete all as specified and directed by Engr - in - Charge. |
| 13 | Dismantling and taking out old UNSV LT PCC Poles of any size, any make and any type from site, complete all as specified and directed by Engr - in - Charge. |
| 14 | Dismantling and taking out old UNSV LT Steel Tubular Poles of any size, any make from site, complete all as specified and directed by Engr - in - Charge. |
| 15 | Dismantling and taking out old UNSV junction boxes made out of Steel/Fibre materials of street light of any size, make and type from site, complete all as specified and directed by Engr - in - Charge. |
| 16 | Dismantling and taking out old UNSV Street light fittings(60/70/90) watts along with all accessories, of any capacity, size, make and type from site and deposited to MES store for refixing or give to contractor as schedule of credit complete all as specified and directed by Engr - in - Charge. |
| 17 | Dismantling and taking out old UNSV GI/MS pipe brackets of street light of any size, make and type from site, and deposited to MES store for refixing or give to contractor as schedule of credit complete all as specified and directed by Engr - in - Charge. |
| 18 | Dismantling and taking out old UNSV LT Bus Bar chamber along with all accessories, of any size, make and type from site, complete all as specified and directed by Engr - in - Charge. |
| 19 | Dismantling and taking out old UNSV Street Light Timer Box along with all accessories, of any size, make and type from site, complete all as specified and directed by Engr - in - Charge. |
| 20 | Dismantling and taking out old UNSV LT Feedar Pillar Box (LT Panel) along with all accessories, of any size, make and type from site, complete all as specified and directed by Engr - in - Charge. |
| 21 | Dismantling and taking out old UNSV GI Pipe 50/80 mm dia with all accessories, of any capacity, size, make and type from site complete all as specified and directed by Engr - in - Charge. |
| 22 | M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection with fixed to the pole or wall etc including suitable fittings for cable protection complete all as specified and directed. |
| 23 | Material and labour for GI tubing light grade 80 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole including fittings complete all as specified and directed. |
| 24 | Supply and erecting in true vertical or to be planed as strut, steel tubular swaged welded pole complete with MS base plate final taper plug, bolt, nuts & screw, 6mm thick of size 300mmx300mm welded at the centre of the pole, type 410 SP-31 (09 Mtr long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zinc chrome primer and two coats of aluminum paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three black and three white bands at lower portion of pole each of 300mm height at 300mm spacing complete all as specified incl dismantling old one complete all as directed and specified. NOTE :- Earth work, Cement concrete in foundation, coping etc. will be measured and paid separately under relevant item. |
| 25 | M&L for PCC 1:2:4 type B-1 with 20 mm graded aggregate for coping of poles etc, including form work complete all as specified and directed. |
| 26 | M&L for PCC 1:4:8 type D-2 with 40 mm graded aggregate as in foundation complete all as specified and directed. |
| 27 | M&L for PCC 1:3:6 type C-2 with 40 mm graded aggregate as in foundation of poles and stay including form work complete all as specified and directed. Please Enable Macros to View BoQ information |
| 28 | M&L for PCC 1:3:6 type C-2 with 40 mm graded aggregate as in foundation of poles and stay including form work complete all as specified and directed. Please Enable Macros to View BoQ information |