| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All Kind of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5Taking 20% of Q.V.I(1A) |
| 3 | Dumping stone including cost of stones.in Horizontal on level |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate |
| 6 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level ::1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.Q.V.I(6+7+8) @ 110kgs/cum |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns etc. for mass concrete. |
| 11 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Columns, pillars, piers, abutments, posts and struts. |
| 13 | Suspended floors, roofs, landings, balconies and access platforms. |
| 14 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 15 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 16 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class Kail wood |
| 17 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (PartI) non-decorative type, core of block board construction with frame of 1st class hardwood and well matched commercial 3ply veneering with vertical grainsor cross bands and face veneers on both faces of shutters : 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 18 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class Kail wood |
| 19 | Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge, complete with;Budloo wood |
| 20 | French spirit polishing with Two or more coats on new works including a coat of wood filler |
| 21 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 22 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) sqm |
| 23 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.Q.V.I (21B+18) |
| 24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primerQ.V.I (22A) |
| 25 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including Hot finished welded type tubes Entrance gate @ 7kgs/sft |
| 26 | Providing & fixing 12mm thick pre laminated flooring of approved brand as per direction of engineer incharge complete job AC-4 incl. carriage |
| 27 | Providing and fixing 12mm thick ply board with 4\\" width plank tongued and grooved, incl. placing in position complete job. |
| 28 | Providing & Fixing Fan Box |
| 29 | Providing & Fixing Conceal Box |
| 30 | Wiring for light point 6amp socket/exhaust fan point / call bell point /with 1.5 Sq.mm PVC FR insulated copper conductor single core in surface/recessed medium class PVC conduit, suitable size MS box and earthing the point with 0.75 Sq.mm. FR PVC insulated copper conductor single core cable as required. |
| 31 | Wiring for 16amp socket outlet with 2.5mm/ 4.00mm FR PVC insulated copper conductor cable in existing recessed PVC conduit , including sheet as required. |
| 32 | Supplying and fixing of 25mm PVC conduit capping along with accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. |
| 33 | Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 10amp 240 volt single pole mounted in recessed including M.S box complete as required |
| 34 | Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 20amp 240 volt single pole mounted in recessed including M.S box complete as required |
| 35 | Supply and fixing of following single pole and neutral sheet steel MCB distribution board 240 volt on surface recess complete with tinned busbar neutral link earth bar, tin bar, detachable glaud plates, double door interconnected including pointing etc as required 16 way double door SPN. |
| 36 | Supply and fixing of the following light fixtures including all accessories like electronic ballasts coms etc, complete as required concealed/Tube lightning 20 watt 3000k, round LED Luminaries as per Philips |
| 37 | Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing andcommissioning etc, as required. A) Single pole 6/10/20 Amp |
| 38 | B) Double pole 40 Amp |
| 39 | C) Double pole 63 Amp |
| 40 | 3 modular plate |
| 41 | 8 modular plate |
| 42 | 12 modular plate |
| 43 | Ceiling fan regulator |
| 44 | Providing & fixing of ceiling fan complete job |
| 45 | Supplying and fixing of 120 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall.Wipro LR02 -501-XXX-57-G1or equivalent approved make |
| 46 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 47 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 48 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm |
| 49 | Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 50 | Providing and fixing C.P Brass toilet paper holder |
| 51 | Providing and fixing of Soap Dish (C.P Brass) with brackets etc |
| 52 | Providing and fixing brass bib cock of approved quality. 15mm nominal bore. |
| 53 | Providing and fixing flow trap of PVC . |
| 54 | Providing and fixing floor jail. |
| 55 | Providing and fixing soil, waste and vent pipes 110mm dia PVC. |
| 56 | Providing and fixing soil, waste and vent pipes 90mm dia PVC. |
| 57 | Providing & fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SOR 7.4 UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropytene random fitings 1/C fixing the pipe with clamps at 1.00m spacing. This includes testing of joints complete as per direction of Engineer-in-charge. (concealed work including cutting chases and making good the walls etc.)Pn-16 pipe, 25mm 00 |
| 58 | Pn-16 pipe, 32mm 00 |
| 59 | Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape for inner wall fittings complete job including carraige 19mm thick, 50mm dia (OD) (PPR 25mm) |
| 60 | Providing & fixing heat tape 33 watt on PPR pipes made of denforced or chromelox or equivalent make as approved by engineer in charge, complete job. |
| 61 | Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, tapping with cello tape aluminium sheet 26 gauge cladding with dia complete job including carraige 19 mm thick, 50mm dia (OD) (PPR Pipe 32 mm) |
| 62 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia |
| 63 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and color. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. |
| 64 | Providing and fixing PVC waste pipe of required dia including bends, Tee door bend, L bend trap jointed with addisive material ISI marked like prince, vector or equivalent brand all complete job 110mm dia bore |
| 65 | Providing and fixing PVC waste pipe of required dia including bends, Tee door bend, L bend trap jointed with addisive material ISI marked like prince, vector or equivalent brand all complete job 90mm dia bore |
| 66 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 67 | Providing and fixing wash basin with C.I.brackets,15mm dia C P Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a)White Vitreous China Wash basin size 550 x 400mm with a15mm C P Brass single hole basin mixer |
| 68 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 69 | Providing and fixing 100 mm sand cast iron grating for gully, floor or Nahani trap. |
| 70 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 71 | Providing and fixing of material for the insulation of water storage tank with nitrile sheet, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, aluminium sheet 26 gauge cladding with dia complete job 19 mm thick nitrile sheet. |
| 72 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 73 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 74 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 75 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stackingCement & Steel (avg. lead 2km) |
| 76 | Sand & Stone agg (20mm n/s) (avg. lead 10km) |
| 77 | Soling stone (avg. lead 15km) Please Enable Macros to View BoQ information |