| 1 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 2 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 3 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. 3 X 10 sq. mm (22mm) |
| 4 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. 3½ X 25 sq. mm (28mm) |
| 5 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 6 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMI- EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 5700°K/6000°K SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 50 watt |
| 7 | Fabrication, Supply ,Installation ,Testing and Commissioning of Outdoor type double door LT FEEDER PANEL with following specifications: CRCA Sheet of 1.6 mm, Grey Color size 700x700x300 mm with 100 A bus bar with suitable space for incomer Cable , 1 no incoming 100 A 4P 30 KA MCCB & outgoing 6 nos 32A 2P/10 KA MCB+ 2 nos 40A, 10KA, 2P MCB C Curve with suitable size bus bar, 1 nos 24 hours running digital timer with 63 Amp 4P contactor, RYB and ON -OFF indicating Lamps -230V with Auto mannual selector switch and mounted on 40X40X6 MM MS angles supports complete (450mm) and panel hight not less than 450 mm from ground level. Drawing should be approved by engineering Incharge. |
| 8 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50 hz, Operating temp range 0 deg to 50 deg centigrade, internal surge protection as per IEC 60598, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >70 , under voltage and over voltage protection, open and short circuit protechtion, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 5700°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥100 lm/Watt output. LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 500 Watt |
| 9 | Fabrication, Supply ,Installation ,Testing and Commissioning of Outdoor type LT FEEDER PANEL with following specifications: CRCA Sheet of 1.6 mm, Grey Color size 300x300x150 mm with suitable space for incomer Cable, 1 no incoming 32 A 2P 10 KA MCB & outgoing 4 nos 10A 1P/10 KA MCB C Curve and mount on wall ,Drawing should be approved by engineering Incharge. |
| 10 | Supply of Aluminum conductor XLPE insulated sheath armored cable of 1.1KV grade conforming to IS: 7098. 3 Core 10 sq mm |
| 11 | Supply of Aluminum conductor XLPE insulated sheath armored cable of 1.1KV grade conforming to IS: 7098. 3.5 core 25 sq mm Please Enable Macros to View BoQ information |