| 1 | Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for cement concrete (1:4:8) Type D-2 , (40 mm graded crushed stone aggregate) , 100 mm thick, as sub-base and similar works complete all as specified and as directed. |
| 3 | M&L for cement concrete (1:4:8) Type D-2 , (40 mm graded crushed stone aggregate) , 50 mm thick, as sub-base and similar works complete all as specified and as directed. |
| 4 | M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in coping on edges etc including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and as directed. |
| 5 | Supply and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including dismantling of existing tiles/paver block etc. complete all as specified and as directed. |
| 6 | M&L for cement concrete 1:2:4 mix type B-0 (using 12.5 mm graded crushed stone aggregate) as in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, complete all as specified and as directed. |
| 7 | Demolition of brick or stone masonary including all necessary arches, pillars, quions etc built in cement mortar complete all as specified and as directed. |
| 8 | Demolition of reinforcement cement concrete of any description and any position not otherwise specifically provided complete all as specified and as directed. |
| 9 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 10 | Dismantling wrought iron or mild steel / cast iron work of any description (steel window & Grill) complete all as specified and as directed. |
| 11 | Dismantling old serviceable/unserviceable barbed wire including removing of unserviceable barbed wire from site and serviceable materials kept in safe custody for re-use complete all as specified and as directed. |
| 12 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 13 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, & not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil, complete all as specified and as directed. |
| 14 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and as directed. |
| 15 | Removing excavated material exceeding 250 m but not exceeding 500 m and deposited where directed complete all as specified and as directed. |
| 16 | M&L for Hard core of broken stone or boulders of gauge exceeding 63 mm but not exceeding 100 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rolled / rammed to a true surface complete all as specified and as directed. |
| 17 | M&L for PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundations and mass concrete including necessary form work & complete all as specified and as directed. |
| 18 | M&L for RCC M-25 (Design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete including necessary form work complete all as specified and as directed. |
| 19 | M&L for RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts including necessary form work complete all as specified and as directed. |
| 20 | M&L for RCC M-25 (Design mix) using 20 mm graded crushed stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses including necessary form work complete all as specified and as directed. |
| 21 | M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 3.00m high from base etc. complete all as specified and as directed.Note : The earth required for forming embankments will be taken from removal qty of item No 15. |
| 22 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe 500/550d grade complete all as specified and as directed. |
| 23 | All as per srl item No. 22.00 here-in-before but 5 mm dia and over including 10 mm dia in stirrups, spaces and binders etc complete all as specified and as directed. |
| 24 | M&L for old size Brick work with sub class 'B' bricks, straight or curgved in cement mortar 1:4 straight or cuved on plan to exc 6m mean radius complete all as specified and as directed. |
| 25 | M&L for Brick work with sub class \\"B\\" bricks straight or curved on plan exceeding 6 Metre mean radius in cement mortar 1:6 complete all as specified and as directed. |
| 26 | All as per srl item No 25.00 herre-in-before but except bricks. |
| 27 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in surafce channel and drains complete all as specified and as directed. |
| 28 | M&L for 15 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:4 mixing with water proofing compound (WPC) as per manufacturer's instruction and finished even and fair without using extra cement complete all as specified and as directed. |
| 29 | Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 40 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. complete all as specified and as directed. |
| 30 | Supply only Liquid water proofing compound complete all as specified and as directed. |
| 31 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 grade E-165 complete all as specified and as directed. |
| 32 | M&L for mild steel angle post or struts in fencing fixed independently including cutting and bending to shape as directed drilling holes, notching for wire etc. conforming to Fe-290 grade E-165 complete all as specified and as directed. |
| 33 | M&L for applying two coats of cement based paint over one coat of cement primer on walls after preparation of newly plastered surfaces complete all as specified and as directed. |
| 34 | M&L for applying one coat of cement based paint on wall complete including the preparation of old plastered surfaces complete all as specified and as directed. |
| 35 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide chrome primer complte all as specified and as directed. |
| 36 | M&L for preparation of old painted steel or steel based surfaces by any discription not other wise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 37 | S&F in repair factory made SFRC manhole / drain cover of any size any shape (square/rectangular/circular) 70 mm thick with frame set in cement mortar 1:4 complete including demolition of exising unserviceable manhole / drain cover all as specified and as directed. |
| 38 | M & L for Precast RCC 1:2:4 type B-1 (using 20 mm gradedcrushed stone aggregate ) as in drain cover slab etc including necessary form work & demolition of existing unserviceable drain cover complete all as specified and as directed. |
| 39 | M&L for two coats of synthetic enamel paint on new concrete or plastered surfaces (as in kerb stones etc) over a coat of primer including preparation of new surface complete all as specified and as directed. |
| 40 | M&L for one coat of synthetic enamel paint on old concrete or plastered surfaces (as in kerb stones etc) including preparation of old surface complete all as specified and as directed. |
| 41 | M & L for restraining and resecuring including making good staples, plain mild steel wire ,in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. complete all as specified and as direted. Note :Each line of wire to be measured. |
| 42 | S&F galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of post including securing and tying at crossing with and provision of galvanised mild steel wire staple or steel pins etc complete all as specified and as direted. Note : Each line wire to be mesured. |
| 43 | M&L for punched tape Concertina Coil (including spike and handle) with 50 turns and 450 mm to 600 mm dia, width of barbed 9mm and spacing of clips 23.5 to 24.5mm C/C weight of each coil will be 15.2 + 5% Kg without packing. Coil length will be 15 mtr when opened up and including dismantling of existing concertina coil etc complete all as specified and as direted. |
| 44 | M&L for cement concrete 1:2:4 mix type B-0 (using 12.5 mm graded crushed stone aggregate) as in steps, seismic and other similar bands, parapets and railings up to 60 cm in height, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, complete all as specifiedand as directed. |
| 45 | S & F PVC (SWR) pipe, 110 mm dia (ISI marked) in any length embedded in cement mortar for weep holes at locations complete all as specified & as directed. |
| 46 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and levelling, getting out getting out in Soft/loose soil complete all as specified & as directed. |
| 47 | Surface dressing not exceeding 15 cm deep complete all as specified and as directed. |
| 48 | Cutting holes in brick walls in built in cement mortar or cement lime mortar exc half brick but not exc one brick complete all as specified & as directed. |
| 49 | Cutting chases ,pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges or landings, steps, cills, sunshades,shelves,lintel,etc and cutting in chases for concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth. complete all as specified & as directed. |
| 50 | M&L for steel work in tubuler trusses including special shaped washer, cleats etc complete using ERW or induction butt welded tubes confirming to IS: 1161-1979 grade st - 240 complete all as specified & as directed. |
| 51 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed. |
| 52 | Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplus soil to distance n.exc 50m and making good surface in soft/loose soil complete all as specified and directed . |
| 53 | M & L for Cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified & as directed. |
| 54 | S&F for 11 to 15 mm mild steel screws bolts (machine made) with hexagonal or square heads at one end and screws both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm not exc 10 cm long complete all as specified & as directed. |
| 55 | S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plate, riveting, etc n.exc 10 kg each brackets, conforming to Fe-290. Gde E-165 complete all as specified & as directed. |
| 56 | M&L Cement concrete 75 mm thick type C-2, 1:3:6 (40mm graded aggregate) as in base of floor complete all as specified & as directed. |
| 57 | S& F for thick machine pressed precast concrete interlocking paver block any shape and size,with grey cement and pigment to match, confirming to IS 15658-2006 of 80mm thick M-40 grade laid over 50 mm thick sand cushioning complete all as specified and as directed. |
| 58 | M & L for cement concrete 1:3:6 type C-1 1:3:6 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops; rounded or chamfered on edges complete all as specified and as directed. |
| 59 | Material and labour for pre-cast cement concrete type B1 1:2:4 (20mm graded aggregate) as in kerb stone (factory made) on road and path including exavating in line n.exc 20cm in width and 30cm deep with 50mm thick PCC 1:4:8 in sub base of exavated area lay/fix the curve stone over PCC and packing the same duly retuning filling and pointing the gaps between curve stones with grey cement complete all as specified and as directed Please Enable Macros to View BoQ information |