|
| 1 | Pipeline Work Under CSD Pal Road Juridication |
| 2 | PHED REVISED BSR 2023/1.2.5 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 3 | 300mm DI K-9 |
| 4 | PHED REVISED BSR 2023/4.1 Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in trenches of required width and gradient for laying and jointing of pipe lines, including excavation for socket, and dressing of sides, ramming of bottoms, depth up to 1.5 mtr. including taking out the exacavated soil, and then returning the soil as required in layer not exceeding 20cm in depth including consolidation each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 MTR. including all safety provisions etc ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 5 | PHED REVISED BSR 2023/4.5 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 6 | PHED REVISED BSR 2023/4.8.1 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work |
| 7 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 8 | PHED REVISED BSR 2023/6.8.1.7 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 9 | 300 mm dia |
| 10 | PHED REVISED BSR 2023/6.11.1.7 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal Nut- Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 11 | Class PN 1.6 |
| 12 | 300 mm dia |
| 13 | PHED REVISED BSR 2023/9.1.1.3 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications andstandard drawings and as directed by Engineer-in-Charge |
| 14 | For Class-AA loading |
| 15 | Sluice valve chamber of size 1.26m x1.185m x1.88mfor pipe size-from 200-to-300mm |
| 16 | PHED REVISED BSR 2023/11.1.8 SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 17 | EFM 300 MM |
| 18 | PHED REVISED BSR 2023/11.4.1 .SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, Normal Powered 24VDC, Type of Transmitter: Two Wire ( 4-20 mA), Cable Entry:1/2\\" NPT (F), Sensor Material: PP, slip-on Flange: 2 ½” Flange, Material of Construction for Slip-on flange: PP, output 4~20mA, HART compatible, accuracy +/_ 0.2 % as per detailed Technical specification, scope of work and direction of Engineer in charge. |
| 19 | Measuring range 0.0 to 6.0 mtr |
| 20 | PHED REVISED BSR 2023/9.2.1.1 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications andstandard drawings and as directed by Engineer-in-Charge. |
| 21 | For Class-AA loading |
| 22 | Air valve chamber of size0.9m x1m x1.695mfor air valve size-from 50 mm-to-80mm |
| 23 | PHED REVISED BSR 2023/6.6.2.3 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 24 | For Class-PN1.6 |
| 25 | 80 mm |
| 26 | Pipe Line work Under Chopsani Filter house Jurisdiction |
| 27 | PHED REVISED BSR 2023/1.1.2&4 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 28 | 100 mm (For Mahalaxmi to Gopal Bari & Sar Pratap Colony) |
| 29 | 200 mm (In Front of Rajeev Gandhi Station to Meghwal Basti) |
| 30 | PHED REVISED BSR 2023/4.1 Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in trenches of required width and gradient for laying and jointing of pipe lines, including excavation for socket, and dressing of sides, ramming of bottoms, depth up to 1.5 mtr. including taking out the exacavated soil, and then returning the soil as required in layer not exceeding 20cm in depth including consolidation each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 MTR. including all safety provisions etc ground moulded chamber burnt bricks with including cost and conveyance of all materials and including all labour charges etc complete |
| 31 | PHED REVISED BSR 2023/4.3 .1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: |
| 32 | Ordinary rock |
| 33 | PHED REVISED BSR 2023/4.5 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 34 | PHED REVISED BSR 2023/4.8.1 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work |
| 35 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 36 | PHED REVISED BSR 2023/6.8.1.2, 5 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 37 | 100 mm dia |
| 38 | 200 mm dia |
| 39 | PHED REVISED BSR 2023/9.1 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications andstandard drawings and as directed by Engineer-in-Charge. |
| 40 | For Class-AA loading |
| 41 | 9.1.1.2 Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm |
| 42 | 9.1.1.3 Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm |
| 43 | RUIDP BSR 2023/19.81 Providing, installation, testing and commissioning of vacuum FeedGas Chlorinator system with all accessories and making connectionwith existing pipeline required including supply & installation ofejector unit, Vacuum chlorination unit, trunnion roller support,auxiliary container valve, flexible copper connector, manifold valve,tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gasfilter, pressure reducing valve, chlorine gas pipe with fittings,diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve oninjector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NBGI pipe for pump suction & delivery, 25 NB GM gate valve on pumpsuction & delivery, 25 NB GM 'Y' type strainer on pump suction, 25NB GM Check valve on pump delivery, pressure gauge with Isolatedvalve on pump delivery and chlorine booster pump with motor ofrequired capacity including safety equipment complete in all respectas per specification and the direction of the Engineer |
| 44 | PHED REVISED BSR 2023/5.2.2 Providing, installation, testing and commissioning of Mono block Vacuum pump set with base plate including C.C. foundation / cross channels / RSJ frame and foundation bolts etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge. |
| 45 | 2.2 KW (3 HP), three Ph |
| 46 | PHED REVISED BSR 2023/5.1.1.2 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 47 | Centrifugal Monoblock Pump set (Single Stage) |
| 48 | 3.7 KW (5.0 HP) |
| 49 | PHED REVISED BSR 2023/5.6.1 &5.6.3 Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 50 | 0.75 KW (1.0 HP) |
| 51 | 2.2 KW (3.0 HP) |
| 52 | Non BSR approved by CE (U&NRW) Raj Kaj No 14596354/ dated 05.06.2025. P & F of GSM/GPRS based data transmitter device for water meter compatible to SCADA System. |
| 53 | RUIDP BSR 2023/47.6 Design, Manufacture, Supply, Installation, Testing andCommissioning of Indoor type PLC Panel of size approx. 1000 mm X 600 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following:- Programmable Logic Controller (PLC) with Dual Hot Redundant CPU, Power supply, Communication Module, IO & Processor rack (Standard DC), Backup Interface/Expansion Module, Rack (Backplane) 10 slots for IO and Processor. SCADA software shall have facility VPN, OPC, Smart Client, Web Enabled, Automation Report Generation, Archiving, Treands, Data Logging, etc.including following Configuration: |
| 54 | MCB 16A DP |
| 55 | MCB 6A DP |
| 56 | SMPS 100-240V AC/ 4.5A/24 VDC |
| 57 | Selector Switch (Auto/Manual) & Local / Remote |
| 58 | Control Relays |
| 59 | Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm110VAC, with, |
| 60 | Electronic Hooter |
| 61 | Control Transformer 200VA |
| 62 | Emergency STOP Push Button |
| 63 | Panel Cooling Fan & Filter |
| 64 | Panel Light with Door Switch, 7W |
| 65 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 66 | Control Indication Lamp for 24VDC, 220VAC |
| 67 | Push Button |
| 68 | Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 69 | Panel Hardware, lugs, terminations, ferrules,name plate Etc. |
| 70 | UTILITY SOCKET 16A, 3 PIN |
| 71 | HMI Display 15 Inch, Colour |
| 72 | Isolators Dual Output, 24VDC |
| 73 | Ethernet Switch ( Managed) |
| 74 | Operator Station including, Core i5 processor, 8GB RAM, 1TB SSD, DVD RW Drive, RS-232/485/RJ45 Port, 1 Parallel Port, 4 nos. USBPort, 2x Ethernet Cards, Keyboard, Opticalmouse, 32'' LED monitor, Latest windowsprofessional, Anti Virous, etc. |
| 75 | Engineering Station including, Core i7 processor, 8 GB RAM, 1TB SSD, DVD RWDrive, RS-232/485/RJ45 Port, 1 Parallel Port, 4nos. USB Port, 2x Ethernet Cards, Keyboard,Optical mouse, 32'' LED monitor, Latest windowsprofessional, Anti Virous, etc. |
| 76 | Run Time & Development Programming andTroubleshooting software for PLC, HMI, SCADA,VPN, Web Client - OWS |
| 77 | Black and white, A4 Size Laser Printer , copier,scan |
| 78 | Hi-Speed USB 2.0 port; built-in Fast Ethernet 10/100Base-TX network port; built-in WIFI802.11b/g/n |
| 79 | Online UPS 3 KVA with 60 min Backup time. |
| 80 | Non BSR approved by CE (U&NRW) Raj Kaj No 14596354/ dated 05.06.2025. Maintenace of Scada system for 5 year |
| 81 | OPERATION AND MAINTAINANCE FOR 5 YEAR |
| 82 | PHED O&M BSR 2020 /7.1 Maintainance of Pipelines irrespective of size & material which includes repairing of bursts & leakages pollution control, survey & removal of choking, disconnection of illegal connections, collection & recording minimum 10 nos. residual chlorine samples during daily supply timings interconnections and all works related to pipeline network in existing distribution /rising main pipelines of all sizes by digging out suitable size of pit in soft and loose soil including cutting of black top, WBM & CC Top of road of any size at work site. THis will also include cutting of pipe end, fixing of pipe piece with jointing material to make repair leak proof and then refilling of excavated tench/pit /road shall be done properly i.e. after a layer of 20 cm proper watering and ramming in layers. For entire Job Contractor will use their Own T&P. Contractor with his own resources shall arrange de-watering, JCB & Tractor Compressor if any and restore any amenity at his own cost damaged while performing the work inthis item. The work include daily patrolling and repair and leakages within stipulated time and complete maintainance of pipeline network of rising and distribution pipeline network within the scope of work for per Km Pipeline per month. Jointing Material shall be provide by the department. |
| 83 | Minimum labour for a following kms pipelines to be deployed. |
| 84 | 01km to 50 km - one fitter-II & Two Beldar |
| 85 | PHED O&M BSR 2020 /7.5.1 Daily periodical operation of valves at supply times for specified by department per sluice valve per month. (Valve Rod and Cap to be arranged by contractor) |
| 86 | 80-300mm |
| 87 | PHED O&M BSR 2020 /7.8.7 Maintenance of centrifugal pump sets and motor/ Monoblock including cost of rewinding of motor, material components & accessories required to repair pump sets, starters etc. of electric panels, deinstallation and re installation of pump sets complete in all respect for per Centrifugal pump set with panel per month. maintenance of history sheet as directed by Engineer-in-charge for centrifugal pump set per month.Operated load of Centrifugal Pump sets (HP) |
| 88 | 41.0 HP to 50.0 HP |
| 89 | PHED O&M BSR 2020 /7.6.1 Running Expenditure of Pumphouse which includes complete operation of pump motor, maintainance of log books as directed by Engineer- in charge, general un-keeping of premises , security arrangement, regular chemical dosing in CWR Cleaning and desilting of SR/CWR/SUMP once in every six month, daily valve operation under the campus of pump house and all other works as mentioned in scope of work in tender document for per pump house per month. (power supply minimum 16 hrs) (excluding repairing of pumping machinary etc. |
| 90 | up to 100 HP |
| 91 | Estimate of Material for O&M |
| 92 | RUIDP BSR 2022/19.58Providing, lowering, laying, aligning, fixing in position and jointing CID- joint class-15 as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per directionof Engineer |
| 93 | 300 mm dia Please Enable Macros to View BoQ information |