|
| 1 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil, Manual Means, Depth up to 3 m |
| 2 | Cement Concrete 1:2:4 complete in all respect. |
| 3 | Plain Cement Concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechenically mixed, placed in foundation and coompacted by vibration including curing for 14 days. |
| 4 | Plain/Reinforced cement concrete M-25 in sub structure complete as per drawing and technical specifications.with batching plant transit mixer and concrete pump |
| 5 | PlainlReinforced cement concrete (RCC Grade M-20 ) in Foundation complete as per drawing and MORT&H MoRT&H Specifications 1500,1700 and 2200 With Batching Plant, Transit Mixer and Concrete Pump |
| 6 | Providing, Stringing out, cutting, jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all artage, cost of rubber ring. Supply of D.I. Pipe DI-K7 600mm i/d pipe |
| 7 | Providing, Stringing out, cutting, jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all artage, cost of rubber ring. Supply of D.I. Pipe DI-K7 500mm i/d pipe |
| 8 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 9 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and MoRT&H Specifications |
| 10 | Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting type IV as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to backsupport frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications |
| 11 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge) .600mm i/d Sluice Valves flanged |
| 12 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge) . 500mm i/d Sluice Valves flanged |
| 13 | Supplying and laying D.I.specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.(D.I. specials above 300mm i/d MS Bend 600 mm Dia & 500mm dia Please Enable Macros to View BoQ information |