| 1 | M&L for preparation of existing old painted surface of any description such as Panels any height and painted completed with one coats of primer (superior quality) and in smokey greay color all around the panels. (Make of Paint : Asian, Berger or equivalent.) |
| 2 | Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 450 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ,250 Amps 25KA micro processor -01 No.(ii)Motorised Changeover Switch SS Enclosure 250 Amp -02 Nos(B) OUTGOINGi) MCCB, 4 Pole,415V, 50HZ 125 Amps 16 KA adjustable thermal and magnetic -01 Nos (ii) MCB, TPN 'C' Series,240V, 50HZ 63 Amps 10KA -04 Nos (iii) MCB , SPN 'C' Series ,240V/415 V , 50HZ 63 Amps 10 KA -04 Nos (iii) MCB , SPN 'C' Series ,240V/415 V , 50HZ 32 Amps 10 KA -04 Nos (iv) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(v) LED Type Phase indicator lamps for three phases set of three - 01 set (vi) Busbar chamber having insulated aluminium busbar, each suitable for 450 Amps for three phases and neutral -01 Set (vii) Spare space for MCCB of same capacity -01 Nos |
| 3 | M & L in repair for fabrication of bus bar chamber of size 80cmx60cmx40cm for 415 volts 3 phase 4 wire system with MCCB 400A ,25 KA ,4 pole, out going MCCB 63 Amps - 04 Nos ,outdoor type, with digital volt amp meter ,double door, withpedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and out going cable including grouting of panel board 1.2 mtr above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge .Note :- Comprising of 4 nos. Aluminium bus bar 200 Amp for phases & 100 Amp for neutral mounted on DMC/ porcelain insulator support complete all as specified and directed. |
| 4 | Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all the three phases, checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that load is nearly balanced in all the three phase complete all as specified and directed. |
| 5 | Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB\\"s.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMFAPFC panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage.(Notes :-This items includes the cost of cleaning & rewiringof panel. Spare parts required shall be measured and paid for separately under respective items as supply only) |
| 6 | Supply only in replacement of APFC microprocessor based relay up 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make-L&T/EPCOS/Siemens |
| 7 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T |
| 10 | Supply only of capacitor duty contactor 3 phase suitable upto 5 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge. Make- Epcos, L&T |
| 11 | Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Supply only in replacement of current transformer of ratio 100/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supply & fixing in repair of MCB SP 6 to 32 Amps, curve 'c' ,10 KA complete all as specified and directed by Enginner-in-Charge. |
| 14 | Supply & fixing in repair of MCB SPN 32 Amps, ,curve 'c' 10 KA complete all as specified and directed by Enginner-in-Charge. |
| 15 | Supply & fixing in repair of MCB SPN 40 to 63 Amps, ,curve 'c' 10 KA complete all as specified and directed by Enginner-in-Charge. |
| 16 | Supply & fixing in repair of MCB 40 to 100 Amps, TPN curve 'c' 10 KA complete all as specified and directed by Enginner-in-Charge. |
| 17 | Supply & fixing Start/stop push button complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Supply & fixing in replacement of selector switch rotary type, flush button, 3 way position in one for voltmeter or Ammeter of any range as per existing complete all as specified and as directed by Engineer-in-Charge. |
| 19 | S&F following MCCBs thermal and magnetic adjustable of capacities , mentioned against each as suitable to be housed in existing space including link separator of existing including taking down old UNSV make:-Havells /Legrand/L&T/ Schneider /ABB |
| 20 | MCCB but 40 Amp,4 Pole 415 Volt ,16 KA, Thermally and Magnetic Adjustable |
| 21 | MCCB but 63 Amp, 4 Pole 415 Volt ,16 KA, Thermally and Magnetic Adjustable |
| 22 | MCCB but 100 Amp, 4 Pole 415 Volt ,16 KA, Thermally and Magnetic Adjustable |
| 23 | MCCB but 125 Amp, 4 Pole 415 Volt ,16KA, Thermally and Magnetic Adjustable |
| 24 | MCCB but 160 Amp, 4 Pole 415 Volt ,25 KA, Thermally and Magnetic Adjustable |
| 25 | MCCB but 200 Amp, 4 Pole 415 Volt ,25 KA, Thermally and Magnetic Adjustable |
| 26 | MCCB but 250 Amp, 4 Pole 415 Volt ,36 KA, Thermally and Magnetic Adjustable |
| 27 | MCCB but 400 Amp, 4 Pole 415 Volt ,36 KA, Thermally and Magnetic Adjustable |
| 28 | Supply and fix new digital multifunction meter accuracy Class 1.0, 0.5 › Input voltage measurement range 50-520 VAC , Aux supply 80-300 VAC/DC , CT secondary site selectable 1A / 5A CT/PT site programmable , V, A, F, PF, kW, kVA, Old energy, On and Run hours, site selectable kWh/ kVAh, True PF or Displacement PF site selectable with built in selecter , 3 phase, 0 to 600 volts suitable for mounting on LT panel including taking down UNSV all as specified and as directed. |
| 29 | S & F in repair of on load changer switch in sheet steel enclosure four pole, 415volt, front handle operated of capacity 250 Amp complete, change over switch fixed in panels or on walls as per site requirement including taking down old UNSV change over switch any make and type all as specified and directed by EICMake- Legrand / ABB / Havells Please Enable Macros to View BoQ information |
| 30 | S & F in repair of on load changer switch in sheet steel enclosure four pole, 415volt, front handle operated of capacity 250 Amp complete, change over switch fixed in panels or on walls as per site requirement including taking down old UNSV change over switch any make and type all as specified and directed by EICMake- Legrand / ABB / Havells Please Enable Macros to View BoQ information |