| 1 | Disconnecting and taking down High mast light up to 25 Mtr Height including taking down high mast assy by making necessary arrangement viz telescoping ladder alongwith all safety arrangement and repositing of the same after repairing all as directed, Note Relevent items should be meaured and paid separately. |
| 2 | S & F in repair MS clamp of size 50x3mm fixed with nuts & bolts of size 75x10mm dia with suitable washer of existing size for bracket on pole complete all as directed by Engr-in-Charge. |
| 3 | Taking down existing street light from pole/wall of any type and refixing after repair the same all as specified and directed by Engineer-in-charge. |
| 4 | Repair/Replacement of LED Driver 230 Volt 50 Hz for street light fitting of 40/70/72 watt. |
| 5 | Repair/Replacement of LED Driver 230 Volt 50 Hz for street light fitting of 90/100 watt. |
| 6 | Excavation in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter in depth for taking out cable/ pipe line not exceeding 10 sq meter on plan and not exceeding 1.5 meter depth and getting out in soft/ loose soil complete all as specified and as directed.Note:- (i) During the excavation damage of Road, Electric cable, Signal Cable should be rectified by the contractor without any extra cost.Surface should be matched as existing road.(ii) Digging shall be carried out by manual means only. |
| 7 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed. |
| 8 | Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point . |
| 9 | Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by Engr –in-charge.(Note : Measurement shall be taken after punning down.) |
| 10 | Supply & Lay Brick common burnt clay sub class B confirming to IS-4885 etc complete all as specified directed by Engr-in-Charge. |
| 11 | Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :- |
| 12 | 16 sq mm 4 core |
| 13 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:- |
| 14 | 16 sq mm 4 core |
| 15 | M&L for GI tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes 50 mm dia complete all as specified and directed by Engr-in-Charge. |
| 16 | Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 16 to 25 Sqmm. Please Enable Macros to View BoQ information |
| 17 | Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 16 to 25 Sqmm. Please Enable Macros to View BoQ information |