| 1 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles, complete all as specified and directed. |
| 2 | M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed. |
| 3 | All as per item No. 2.00 here-in-before but except stone, Note: Old stone retrieved from demolition shall be used. |
| 4 | M & L for pre-cast cement concrete block 1:3:6 Type C1 (20mm graded stone aggregate) masonry with solid blocks, exc 10cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 5 | Demolition of cement concrete of any description and in ground floor and paving, complete all as specified and directed. |
| 6 | M&L for cement concrete in foundation filling and mass concrete type D-2 1:4:8 (using 40mm graded stone aggregate) in foundation, complete all as specified and directed. |
| 7 | M&L for cement concrete type C2, 1:3:6 (using 40mm graded stone aggregate) as in surface channels and drains, complete all as specified and directed. |
| 8 | M & L for forming fair finshed drain or channel 30cm inner girth in cement mortar, using extra cement including forms, moulds, mitred/ stopped ends, complete all as specified and directed. |
| 9 | Form work to faces of walls foundation retaining walls, abutments parapets and stair case railings and similar work incl att pillasters, buttresses etc : vertical or to batter rough finishrd surface of concrete in flat, complete all as specified and directed. |
| 10 | Demolition and breaking up drain pipes of 300 mm bore (salt glazed stoneware, AC or reinforced concrete) set in cement mortar, complete all as specified and directed. |
| 11 | M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 300mm bore including packing under and haunching against the sides of pipe after they are laid and tested, complete all as specified and directed. |
| 12 | S & F of 300 mm bore reinforced concrete pipe class NP-2 laid, jointed with collar in neat cement slurry, complete all as specified and directed. |
| 13 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in hard / dense soil, complete all as specified and directed. |
| 14 | Returning filling including spreading, levelling, watering and well ramming in layers not exc 25cm for hard and dense soil, complete all as specified and directed. |
| 15 | Removing excavated material n.exc 50m and depositing where directed where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed. |
| 16 | Demolition of reinforced cement concrete in ground floor and paving not exc 15cm thick, complete all as specified and as directed. |
| 17 | M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slab,chajjas etc.and similar articles with plain faces set in CM 1:6, complete all as specified and directed. |
| 18 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe 410-W as in columns or beams, complete all as specified and directed. |
| 19 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 20 | M &L for rendering 15mm thick in cement mortar 1:4 on concrete/brick/stone surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 21 | S & F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; side hung or barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 including dismantling of old steel frame work, complete all as specified and directed. |
| 22 | M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, kneelers, apex stone, bed plates and the like including weathering slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 23 | M&L for PCC 1:3:6 type C-1 (20mm graded crushed stone Aggregate) as in bond stone in stone walling set in CM 1:6, complete all as specified and directed. |
| 24 | M&L for extra over stone walling for hammer dressing to face stone and dressing of face beds with maximum depression on face from straight edge held against the dressed surface on sand stone n.exc 20mm, complete all as specified and directed. |
| 25 | M&L for raised pointing to random or polygonal rubble, un- coursed or brought up to courses in cm 1:4 , complete all as specified and directed. |
| 26 | M&L for broken stone or boulders hand packing (any thickness) at back of wall over arches etc and raising (or lowering) to the reqd level, complete all as specified and directed. |
| 27 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed as weep holes, complete all as specified and directed. Please Enable Macros to View BoQ information |