| Sl. No. | Item Description |
| 1 | Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 3 | Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dresssd with earth obdiened from excavation of foundation trenches within a lead of 50 m and lift of 1.5 M all complete as per building specification and direction of E.I (Mode of measurement compacted volume.) |
| 4 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing designation 75 Abrick work in C.M (1:6)in foundation and plinth with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials , raking of joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l |
| 6 | Providing 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer Incharge . |
| 7 | Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I. |
| 8 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 9 | Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 14 | Providing 25mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 15 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 16 | Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. |
| 17 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 24 | Supplying, fitting and fixing 35 mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core bended with hight quality phenol formal dehydes synthetic resin both side commerical veneered of standered make with oxidised iron fitting -- do - |
| 25 | Supplying, fitting and fixing 20mm thick solid core type non-decorative double leaf flush shutters in cup boards with black board core blended with high quality phenol formal dehyde synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 26 | Providing T or steel reinforcement of 8,10 mm, 12 mm, &16 mm dia barsas per approved design and drawing excluding carriage of bars to work site, cutting, bending and binding with annealed wie with cost of wire, removel of rust, placing the rods in position all complete as per building specification and direction of E. |
| 27 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 28 | providing Tor steel reinforcement of 10mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 29 | providing Tor steel reinforcement of 12mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 30 | providing Tor steel reinforcement of 16mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 31 | providing Tor steel reinforcement of 20 mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 32 | Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. |
| 33 | Providing and fixing fan hook of 16 mm dia M.S bar 1 metre long bent to requried size and shape placed in position and fixed in R.C.C slab / beem at the time of casting all complete as per building specification and direction of E.I(where materials is not supplied by the deptt.) |
| 34 | supplying , fitting and fixing M.S gril / RECTANGULAR PIPE made of 20x6cmm M.S. FLA asper approved design and drawing , and properly fabricated with joints continous fillet welded and finished smooth , carriage of grill to work site , hoisting as per building specification and direction of E / I WHERE A MATERAIL is not supplied in by the deptt |
| 35 | Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royalty all complete as per |
| 36 | Providing and laying 25mm thick white makrana marble tiles in risers of steps, skirting and pillers of approved quality over 12mm thick base of cement mortar (1:3) and jointed with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 37 | Providing and laying 25mm thick white makrana marble stone slab flooring of approved quality over 19mm thick base of lime mortar (1:1:1) (Lime putty: surkhi: coarse sand) laid and joined with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (II) 300x600mm size |
| 38 | providing and laying 6mm . Precast white glazed tiles in walls over 12mm . Cement mortor (1:3)and jointed with grey cement slurry flush pointed with white cement including rubbing , polishing and cost of curing taxes and royality all complete as per building specification and direcation and ofE / |
| 39 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 40 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 41 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 42 | Providing 6 mm thick cement plaster (1:4) in Celling with clean coarse sand of F.M. 1.5 including screening, curing with all lead and |
| 43 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 44 | Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I. |
| 45 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.. |
| 46 | Prividing French spirit polishing over new wooden surface to give desired texture and gloss with apporoved make and shade of ready mixed french polish including preparing the surface sfter cleaning removing dirt |
| 47 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface |
| 48 | Providing two coats of synthetic enamel paint of apporoved shade and make over steel surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 49 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 50 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturerspecifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of |
| 51 | mortar (Cement: sand -1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready touse, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of |
| 52 | measurement the entire treated surface will be measured.\\" (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TGProduct Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +27°C |
| 53 | Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)(d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items). All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shall |
| 54 | be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\"(e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years. |
| 55 | Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering, and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.- There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+ |
| 56 | Providing and mixing liquid integral water proofing compound in conctrete of plaster as manufacturer specification and as per direction of engineer in charge. Brand. Sika plastocrate plus, MYK proff WP 10, Fosroc-Conplast x 4211C, Dr.Fixit, Pidiproff LW+ or Equivalent |
| 57 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 58 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red. Area of slab over 0.50 sqm |
| 59 | Extra for providing edge moulding to 18mm thick marble stone counters,Vanities etc. over Item No. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite work |
| 60 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight includingchecking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite |
| 61 | panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats,weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of |
| 62 | the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 63 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 64 | 50mm thick factory made soiled both side Prelaminated Panel PVC Chowkhat shutter consisting of frame made out MS tube of 19 guage thickness as per your size . |
| 65 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of |
| 66 | which 75 mm shall be flat and 20 mmshall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side ofthe panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail &bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed tothe styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, andjoined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to bestuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction ofEngineer-in-charge, manufacturer's specification & drawing. |
| 67 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 68 | Casement window double panels with French (False) Mullion with S.S. 304 fricction hinges as per size and wieght of sash,multi-point locking system,zinc alloy (zamak) power Coated handal Using R3 series with frame (55mm& above)x (45mm& above) & sash (55mm& above) x(65mm&above) & French (Flase) mullion (55mm& above) x(65mm&above). (Height upto 1.8m) |
| 69 | Providing and fixing pressed steel door frames confirmig to IS: 4351 manufactured form commercial mild steel sheet of 1.25 mm thickness including hinges jomb, lock jamb, bead and if required angle threshold of mild |
| 70 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 71 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 72 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 73 | 75 mm diameter |
| 74 | 110 mm diameter |
| 75 | Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 76 | 75 mm Coupler |
| 77 | 110 mm Coupler |
| 78 | Single tee with door 110x110x110 mm |
| 79 | Bend - 110mm |
| 80 | Shoe - 110 |
| 81 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete |
| 82 | 75mm dia |
| 83 | 110 mm |
| 84 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied@ 2.20kg/10 sqm |
| 85 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 86 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 87 | Internal work -Exposed -ON - WallProviding and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. |
| 88 | 25 mm nominal outer dia pipes |
| 89 | 32 mm nominal outer dia pipes |
| 90 | 40 mm nominal outer dia pipes |
| 91 | Concealed work including cutting chases and making good the wall etc Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge. |
| 92 | 15 mm nominal outer dia pipes |
| 93 | 20 mm nominal outer dia pipes |
| 94 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 95 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 96 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 97 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stonePattern with anti algae and UV resistance properties to be applied as intermediate finish in desiredpattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with PremiumAcrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge. |
| 98 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 99 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 100 | Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge. |
| 101 | Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I |
| 102 | CHIPS |
| 103 | BRICK |
| 104 | Fly Ash |
| 105 | Earthwork in excavation(As per I.S. 3114/1965 for laying of different types and sizes of pipe so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.(a) For classification of soil item - A ( 20 x 0.6 x 0.6 ) |
| 106 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification for soil item-A& B |
| 107 | Supplying fitting and fixing the following items complet with all material s as per direction of E/I.(b) (i) 600x450mm mirrors of 6mm thick., |
| 108 | Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification anddirection of E/I.(b) With 10 ltr low level PVC cistern |
| 109 | Supplying, fitting and fixing flat back or angular,lipped front vitreous white glazed earthen ware Urinal (Boys ) of Hindustan Parry or any other I.S.S approved make with 5 litres C.I automatic flushing cisterns of reliance for any other I.S.S approved make wihall fittings with C.I or R.S brackets, standered sizes G.I.flush pipe with fitting clamps, 15mm C.I body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C / Alkthene pipe 450mm long with brass coupling at both ends and doing plumbers joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same rtc. all complete as per specification and direction of E/I. |
| 110 | Supplying, fitting and fixing flat back or squtng ,lipped front vitreous white glazed earthen ware Bidet (Girls Urinal) of Hindustan Parry or any other I.S.S approved make with 5 litres C.I automatic flushing cisterns of reliance for any other I.S.S approved make wihall fittings with C.I or R.S brackets, standered sizes G.I.flush pipe with fitting clamps, 15mm C.I body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C / Alkthene pipe 450mm long with brass coupling at both ends and doing plumbers joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same rtc. all complete as per specification and direction of E/I. |
| 111 | Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. |
| 112 | (i)125mm thick wall |
| 113 | (ii)250mm thick wall |
| 114 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 115 | Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required. |
| 116 | Group B |
| 117 | Group C |
| 118 | Twin Control Point wiring in PVC conduit, with modular type switch:-Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch,modular plate, sutiable size G.I box etc as requried. |
| 119 | Power plug wiring in PVC conduit (2x4 sq.mm):-Power plug wiring in PVC conduit (2x4 sq.mm):-Wiring for light / power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surfface / recessed PVC conduit along with 1 Nos. 4 sq.mmFR PVC insulated copper conductor single core cable for loop earthing as requried. |
| 120 | Circuit /sub main wiring in PVC conduit :-Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. |
| 121 | 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 122 | 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 123 | 2x4.0 sq.mm + 1x4.5 sq.mm earth wire |
| 124 | 2x6.0 sq.mm + 1x6.0 sq.mm earth wire |
| 125 | 2x10 sq.mm + 1x10 sq.mm earth wire |
| 126 | S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried. |
| 127 | 75 mm x 75 mm x 50 mm deep / (4\\" x 4\\" ) |
| 128 | 72 mm x 146 mm x 48 mm deep / (4\\" x 7\\" ) |
| 129 | 210 mm x 206 mm x 48 mm deep / (10\\" x 12\\" ) |
| 130 | S/F Modular type switch / socket :-Supplying and fixing following modular type switch /socket on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 131 | 5/6 amps, one way switch |
| 132 | 5/6 amps, 3 pin socket outlet |
| 133 | S/F Modular type Electronic Fan Regulator-Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 134 | S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate and switch box exculiding modular plate etc.as requried. |
| 135 | Supply and Fixing Light Plug Point with Modular Type Accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. |
| 136 | S/F power plug point with modular type accessories :- Supplying and fixing sutiable size G.I. box with modular plate cover in front on surface or in recessed including providing and fixing 6 pin , 15/16 amps modular socket outlet and 15/16 amps modular switch connection , painting etc, as requried. |
| 137 | S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried. (Tube+Fan) |
| 138 | S/F Batten holder :-Supplying and fixing battrn / angle holder including connection etc as requried. |
| 139 | ITC fluorescent fitting directly on surface :-Intallation testing and commissioning of pre wired fluorescent TUBE fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling / wall including connection with 1.5 sq. mm. FR PVC insulated copper conduit as requried. |
| 140 | ITC celling fan :- Installation, testing and commissioning of celling fan, including wiring the down rods of standerd leanth (upto 30 mm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as requried. |
| 141 | ITC Exhaust fan upto 450 mm. sweep:-Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the holeto suit the size of the above fan, making good the damage, connection, testing, commissioning etc as required. |
| 142 | S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. |
| 143 | 16 amps, double pole |
| 144 | 32 amps, double pole |
| 145 | 63 amps, double pole |
| 146 | 32 amps, TP&N |
| 147 | S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried. |
| 148 | 200 amps, TP&N, HRC |
| 149 | 400 amps, TP&N, HRC |
| 150 | S/F Busbar chamber :-Providing and fixing following capacity busbar chamber with 4 strips of sutiable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc as requried. 400 amps |
| 151 | S/F Panel montude change over:-Providing and fixing following capacity 4 pole panel mounted change over switches in existing cubcile panel board, making connection earthing the body etc as requried. |
| 152 | S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 153 | 4way,Single door |
| 154 | 6way,single door |
| 155 | 8 way , single door |
| 156 | 4way, Double door |
| 157 | 16way,Double door |
| 158 | S/F S.P. MCB DB :-Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphatize and powder painted inculiding earthing etc.as required.(But without MCB/RCCB/Isolator) 4way (4+12), Single door,Horizontal type |
| 159 | S/F 'B'serise, s.p.MCB:-Suppling and fixing 6amps to 32 amps rating , 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folling poles in the existing MCB DB complete with connections, testing and commissioning et. as requried. 6/32amps, single Pole,\\"B\\" serise |
| 160 | S/F 'C' serise, MCB:-Suppling and fixing ,240 volts \\"C\\"serise miniature circuit breaker suitable for inductive loads of follong poles in the existing MCB DB complete with connections, testing and commisioning etc. as required . |
| 161 | 6/32 amps, Single pole |
| 162 | 6/32 amps, SPN |
| 163 | 40 amps, DP |
| 164 | 50/63 amps TPN |
| 165 | S/F SP MCB blanking plate :-Suppling and fixing Single pole blanking plate inexisting MCB DB complete etc. as required . |
| 166 | S/F SPN RCCB:-Supplying and fixing following rating, double pole, (single neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 16/25 amps |
| 167 | Copper earth plate electrode:-Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt). |
| 168 | S/L 8 SWG copper wire in ground:-Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried. |
| 169 | S/L 25mm x6mm G.I. earth strip in ground :-Supplying and laying 25mm x6mm G.I. strip at 0.50 metre below ground as strip earth eletrode, incoluding soldering etc .as requried. |
| 170 | P/F G.I lighting conductor finial :-Providing and fixing of lighting conductor finial, made of 25 mm dia 300mm long, G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc as rqquried. |
| 171 | Reverting sweating and soldring lighting conductor tape:-Reverting sweating and soldring of copper / G.I tape (with another copper/ G.I tape, base of the final or any another metalic object) as requried. |
| 172 | P/F G.I lighting conductor tape in vertical run :-Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as requried.( for horizontal run ). |
| 173 | P/F Testing joint for G.I lighting conductor :-Providing and fixing testing joint, 20 mm x 3 mm thick copper strip 125 mm long , with 4 nos. of G.I bolts, nuts, check nuts and spring washers etc. complete as requried. |
| 174 | P/F coppre earth tape for lighting conductor :-Providing and laying copper tape 32 mm x 6 mm from earth electrode directly in ground as requried. |
| 175 | 9W, High efficient recess mounted COB LED downlighter with extruded aluminium housing. High efficiency 38 Deg beam reflector optics for effictive thernmal management using aluminium casting. CRI>80, CCT - 4000K,50,000 hrs @ L70 life. IP20, Ambient temp- 0 to 45 DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Cutout Dia-ø90mm. Luminaire lumen ≥ 900 lm. (100 lm/W). Similar to Wipro Make LD98-131-038-40-XXor Equivalent Philips make. |
| 176 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to 15:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC ansulated, copper wire suitable for 230V 50Hz, single phase supply etc complete as required.1200MM (48\\")Ceiling Fan |
| 177 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required.20/22 . Watt LED LIGHT |
| 178 | SIT.C of following rating LED Post top lamp made in die cast aluminium housing with decorative clear/opal acrylic diffuser on existing pipe including connection with 1.5sq.mm. copper conductor etc all complete as required.10/15W LED Post Top Lamp Opel |
| 179 | S.I.T.C of following rating approved make LED Bollard fitting with cylindrical shape of height 600 to 850mm power input-8/9watt with die cast aluminium housing opel with PC diffuser, IP:65/54 protection, conferming to 15:10322 part 5 etc all complete as required. (excluding plinth charge) |
| 180 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, (SINTEX / SINTER) ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but withoutfittings and the base support for tank. |
| 181 | 9\\" (230mm) metal exaust fan |
| 182 | 15/16 Watt LED BULB |
| 183 | Bulk head fitting with 9/10 Watt CFL/LED |
| 184 | D.G Set of Capacity 100 Kva with AMF Panel |
| 185 | 1.0 Tr. 5 Star Split A.C (Inverter Type) |
| 186 | Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) |
| 187 | piller Cock (Long Neck) |
| 188 | Bib Cock (sort Neck) |
| 189 | Towel Rail 24\\" |
| 190 | Toilet Paper Holder |
| 191 | Glass shelf 22' |
| 192 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up toSite. |
| 193 | (a) From 0.00 M to 50.00 M below G.L. |
| 194 | (b) From 51.0 M to125.00 M |
| 195 | (c) From126.0 M to150.00 M |
| 196 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer in-charge |
| 197 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 198 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 199 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 200 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 201 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 202 | Total Schedule Item |
| 203 | Non-Schedule Item |
| 204 | CARVING WORKS on B.wall with painting materials |
| 205 | Add GST 18 % |
| 206 | Add Labour cess 1% Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail