| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling and tress girth upto 300 mm, removal of stumps of tree cut earlier and disposal of unserviceable materials and stacking of sericeable material to be used of auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. as per technical specification clause 201.1 SOR 2.03 |
| 2 | Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2. SOR 3.17 |
| 3 | Construction of Embankment with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2. as per technical specification clause 301.5 SOR 3.16 |
| 4 | Construction of Earthen Shoulders and subgradeConstruction of Earthen Shoulders with shoulder with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2. as per technical specification clause 301.5 SOR 3.18 |
| 5 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. SOR 4.01 B (v) |
| 6 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SOR 4.14 B |
| 7 | Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means. SOR 5.01 |
| 8 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. SOR 5.02 (II) |
| 9 | Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects. SOR 5.04 B |
| 10 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. SOR 5.02 (I) |
| 11 | Providing and laying bituminous concrete with higher capacity batch typehot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects. SOR 5.05 |
| 12 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.90 cm equilateral triangle. SOR 8.04 |
| 13 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.60 cm equilateral triangle. SOR 8.05 |
| 14 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) SOR 8.13 |
| 15 | Type - A, \\"W\\" : Metal Beam Crash Barrier (Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) SOR 8.23 |
| 16 | Solar Powered Road Marker (Solar Stud) Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode.The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280.The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinkikng in 1 Hz.There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhace the life of the marker and a full charge should provide for a minimum autonomy of 50 hours.The height, width and length of the marker shall not be less than 10mmx100mmx100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively.The weight of the marker shall not exceed 0.5 Kilograms.Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.) SOR - 8.35 |
| 17 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. SOR 12.1 (I) B |
| 18 | Providing and laying of PCC M15 levelling course 100 mm thick below the pile cap. SOR 12.41 (MoRT & H) |
| 19 | Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. SOR 12.25 (MoRT & H) |
| 20 | Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical SpecificationRCC Grade M35 SOR 12.40 (D) |
| 21 | Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications Clauses 1000 and 1202 SOR 12.42 |
| 22 | Providing Steel Liner 10 mm thick for piles including Fabricating and Setting out as per Detailed Drawing.For 1200 mm dia pile. SOR 12.22 |
| 23 | Dismantling of Reinforced Concrete Pile head complete as per Drawing and Technical Specification SOR 12.39 |
| 24 | Confirmotory boring at Abutment and Pier Loation SOR - LS. As per TS |
| 25 | Pile Load Test on single Vertical Pile in accordance with IS:2911 (Part-IV)a) Initial and routine load test. As per TS |
| 26 | Pile Load Test on single Vertical Pile in accordance with IS:2911 (Part-IV)b) Lateral Load Test. As per TS |
| 27 | RCC Grade M35 using batching plant, transit mixer & concrete pump Up to 5m Height (Using BMP) SOR 13.05 (H) (MoRT & H) |
| 28 | RCC Grade M35 using batching plant, transit mixer & concrete pump From 5m to 10m Height (Using BMP) SOR 13.05 (H) (MoRT & H) |
| 29 | Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in sub structure complete as per drawing and technical specifications. Clauses 1002, 1005, 1010 and 1202. SOR 13.06 |
| 30 | Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) section IX and clause 2005 of Mort&H specification complete including all accessories as per drwaing and technical specifications. SOR 13.16 (MoRT & H) |
| 31 | Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications. SOR 13.08 |
| 32 | Back filling behind abutment, wing wall, return wall complete as per drawing and technical specificationsi. Sandy Material. SOR 13.09 |
| 33 | Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification. SOR 13.1 |
| 34 | Providing and laying Reinforced cement concrete in super-structure as per drawing and Technical Specification. SOR 14.01 (D) Case II (ii) |
| 35 | Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in super-structure complete as per drawing and technical specifications. SOR 14.02 |
| 36 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. SOR 14.04 |
| 37 | Provision of an Reinforced cement concrete crash barrier at the bridge decks& approaches to bridge structures constructed with Rein forced Cement Concrete With HYSD reinforcement confirming MoRT&H Specification and as per details given IRC-5 including dowel bars ,expansion joints filled with pre-moulded asphalt filler board etc.. and approved drawing and at locations directed by the Engineer ,all as specified . Crash Barrier for bridge (Height 1100mm) as per details given in IRC-5 SOR 14.15 |
| 38 | Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. SOR 14.07 |
| 39 | Drainage Spouts complete as per drawing and Technical specification. SOR 14.09 |
| 40 | PCC M15 Grade (1:2.5:5) leveling course below approach slab complete as per drawing and Technical specification. SOR 14.1 |
| 41 | Reinforced cement concrete M-30 Grade approach slab including reinforcement and formwork complete as per drawing and Technical specification. SOR 14.11 |
| 42 | Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation. SOR 14.21 |
| 43 | Filler joint Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. SOR 14.17 (iii) |
| 44 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.SOR 14.16 |
| 45 | Providing and laying boulder pitching on slopes laid over prepared filter media as per drawing and Technical specification.SOR 16.01 |
| 46 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification.SOR 16.05 |
| 47 | Providing and laying of PCC M15 levelling course 150 mm thick below the pile cap. SOR 12.41 (MoRT & H) |
| 48 | Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. RCC Grade M30 using batching plant,transit mixer & Concrete pump. SOR 12.08 G Case 1 |
| 49 | Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications.RCC Grade M30 using batching plant, transit mixer & concrete pump.Height below 5m. SOR 13.05 (G) p |
| 50 | Add 18% GST : |
| 51 | Add 1% Labour Cess: Please Enable Macros to View BoQ information |