| 1 | Repairing of 375 HP & 250 Kw horizontal split casing pump having discharge@950m³/hours at head of 62mtr. At bed no.2 Pump house I&II and bed no.1 Pump house phase-III by replacement of following defective parts:- |
| 2 | P/F of shaft protecting sleeves (gun metal) (02 Nos.) |
| 3 | P/F of neck rings (gun metal) (02 Nos.) |
| 4 | P/F of stuffing box bush (gun metal) (02 Nos.) |
| 5 | P/F of sleeves checknut (gun metal) (04 Nos.) |
| 6 | P/F of rubber rings (02 Nos.) |
| 7 | P/F of ball bearing 6314C-3 (02 Nos.) |
| 8 | P/F Gland cup (01 Set.) |
| 9 | Repairing of pump shaft by remantling of shaft for re-threading and finishing to remove looseness of impellor on shaft along with making keyway etc. (01 job) |
| 10 | P/F coupling pin (11 Nos.) |
| 11 | Replacement of packing sheet, gland dori, grease, nut & bolts etc. as per site requirement (01 job). |
| 12 | Carriage from site to workshop and back. (01 job) . |
| 13 | Dynamic balancing of complete rotating assembly (01 job) |
| 14 | Labour charges for repair, dismantling/refixing alignment of pump set complete in all respect. (01 job) |
| 15 | Replacement, providing and fixing and replacement of soft starter PSTX250-600-70 suitable for running of 150HP 3phase 415 volts electric motor (minimum 250Amp) constructed & tested in accordance with IEC-60947-I should have inbuilt by pass to thyristors for in line 3 wire connection of motor, graphical LCD display. The soft starter shall have coated PCBA's to with stand harsh environment & shall have voltage/torque & full voltage start ramp for slow speed and back ward operation for positioning of motor and shall have torque control to eliminate water hammering to prolong life of the pumping system. The soft starter shall have at limp mode feature to allow the soft starter to operate even with shorted thyristors in one phase, built up motor protection. The soft starter shall integrate motor load protection which shall under no circumstance be disabled when the integrated by pass in used complete in all respect. For pump set 150HP at New Recycling pump house bed No.1. Make ABB/Siemens/Schneider/ Mitsubishi/ Essen/Dantos |
| 16 | Replacement of 250Amp 415volt 36KA MCCB as per IS 60947-2 with thermal magnetic release along with making connection and fixing in panel complete in all respect. 150 HP pump set for 38 west at pump house phase-III bed No.2. Make: L&T/ABB/Schneider/Siemans. |
| 17 | Replacement of AX 150-30 contactor block with AX185 contactor block along with wiring and thimbles etc. to entire satisfaction of EIC complete in all respect for pump set 150 HP at pump house phase I&II. Make: L&T/ABB/Schnelder/Siemans |
| 18 | Replacement, providing and fixing of contactor blocks MNX225 (L&T) Make in soft stator panel for 150 HP pump set for 38 west at pump house phase-III bed No.2 complete in all respect. |
| 19 | Replacement, providing and fixing of spacer type coupling along with coupling pins and rubber bush including cost of making inner dia bore key way for pump set 150HP at new recycling pump house water works sector 39, bed No.2 complete in all respect Make:- Lovejoy, fanner, MRF. |
| 20 | P/F of fuse link (TPN) in open execution 250Amp confirming to IEC 60947-3, with both side terminal shrouds and face barrier along with cost of HRC fuse 250Amp(3No.) complete with removal of old burnt/defective fuse link and making of all connections with contactor block and motor etc. complete in all respect. Make: L&T/Siemens/Schneider/Havells. |
| 21 | Repairing of OCB of 125 KW pump set by replacement of defective/burnt parts such as V bars 03 No, Acing contacts 06 No, Arcing finger 06 No, Main finger 24 No, along with cleaning and decarbonizing of stater of Bed No.2 & 5 at pump house phase - IV, water works Sector-39 Chandigarh. complete in all respect. |
| 22 | Repairing of resistance Regulator of 125 KW pump set by replacement of defective/burnt parts such as bakelite/hilum base board 1 No, Corner Contacts 3 No, Top contacts 15 No, Moving tip operating arm of Bakelite 1 No, Resistance wound on porcelain tube 6 No, Copper insulator with studs 3 No along with cleaning and decarbonizing regulator of Bed No.2 & 5 at pump house phase - IV, water works Sector-39 Chandigarh. complete in all respect |
| 23 | Repairing of OCB of 126 KW pump set by replacement of defective/burnt parts such as V bars 03 No, Acing contacts 06 No, Arcing finger 06 No, Main finger 24 No, along with cleaning and decarbonizing of stater of Bed No.2 at pump house phase - III, water works Sector-39 Chandigarh. complete in all respect. |
| 24 | Repairing of resistance Regulator of 126 KW pump set by replacement of defective/burnt parts such as Bakelite/haylam base board 1 No, Corner Contacts 3 No, Top contacts 15 No, Moving tip operating arm of Bakelite 1 No, Resistance wound on porcelain tube 6 No, Copper insulator with studs 3 No along with cleaning and decarbonizing regulator of Bed No.2 at pump house phase - IV, water works Sector-39 Chandigarh. complete in all respect |
| 25 | Providing and pouring of stater oil in various OCB/Stater/resistance regulator including cost of transportation and dehydration Make: Savita, power oil. |
| 26 | Replacement/Providing and fixing of copper flexible lead single core 120Sqmm of 125 Kw slipring motor of bed no.2 including cost of copper thimble both side, glass tape, PVC tape, brass nut and bolt from starter to motor and regulator to motor at pump house phase-4 water work sector -39,CHD. Make: Havells/BCH/L&T/Finolex. |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture of required color to given an even shades of starter and regulator of Bed No. 2 & 5 at pump house phase - IV, water work sector -39 Chandigarh complete in all respect. |
| 28 | Credit against old material. Please Enable Macros to View BoQ information |