| 1 | Jalamarapalli-II T/W |
| 2 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with well screen as per the necessity for the soft, medium, hard and boulder formation (PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in overburden portion including developing, lowering and conducting yield test etc complete |
| 3 | Labour charges for slotting of 200mm dia PVC Pipe |
| 4 | Cost of 200mm dia PVC blank pipe (sch-80) |
| 5 | Cost of 200mm dia PVC cone |
| 6 | Cost of 200mm dia PVC threaded end cap. |
| 7 | Supplying of Benotonite Powder |
| 8 | Supplying all labour, tools and plant and packing the bore with washed gravel (size P-6) around the pipes in good quality including cost of gravel etc all complete as per the direction of the Engineer-in-charge. |
| 9 | Cost, supplying of 200X80mm dia M.S.T/W Cap with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 10 | Earth work in hard soil for excavation of foundation including dressing and levlling the bed and depositing the soil within 50 mtr. initial lead and 1.5 mtr. initial lift as per direction of Engineer-in-charge. |
| 11 | Filling in foundation and plinth with sand well watered and rammed including cost of sand as per direction of Engineer-in-charge. |
| 12 | C.C(1:4:8) with 4 Cm. size H.B.G metal laying and hoisting etc. complete with curing as per direction of Engineer-in-charge |
| 13 | Brick work with Fly ash bricks of (23cm x 11 cm x 8 cm ) in cement mortar (1:6) in foundation and plinth with curing etc.complete as per direction of Engineer-in-charge. |
| 14 | Cement concrete (1:2:4) for R.C.C. works with 12mm size h.g.b. chips including hoisting and laying etc. complete with curing as per direction of Engineer-in-charge |
| 15 | Providing & supplying of M.S.Rod for for M.S. Reinforcement for R.C.C work including cutting, bending, binding & tying the grills & placing in position including cost of binding wire etc.complete as per direction of Engineer-in-charge |
| 16 | Rigid smooth centering and shuttering for R.C.C. works including false work and dismentling them after casting including cost of materials complete etc. complete for Column base etc |
| 17 | Rigid smooth centering and shuttering for R.C.C. works including false work and dismentling them after casting including cost of materials complete etc. complete for Slab,Column,Beam etc. |
| 18 | Brick work with Fly ash bricks of size (23cm x 11 cm x 8 cm ) having crushing strength not less than 75kg./cm2 with dimensional tolerance + 8% in cement mortar (1:6) in Superstructure with curing etc.complete as per direction of Engineer-in-charge. |
| 19 | 12 mm thick cement plastering with cement mortar (1:6)over brick work with curing etc.complete.as per direction of Engineer-in-charge. |
| 20 | Cement Punning over the cement plastering with curing etc.complete.as per direction of Engineer-in-charge. |
| 21 | Filling F & P with excavated materials, earth, moorum including watering and ramming as directed by the Engineer-in-charge. |
| 22 | 2.5 cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips etc. complete with curing as per direction of Engineer-in-charge |
| 23 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade over a coat of Primer & two coats of White washing including cost of paint,Primer & shell lime etc. complete as per direction of Engineer-in-charge |
| 24 | Providing ,fitting & fixing of shutter plate with 18SWG MS Sheet confirming to IS No.6248/7 framed with 32mmx32mm angle iron chowkhat of following size and including all costs,taxes etc complete with priming & painting as per satisfaction of Engineer-in-Charge. Window= (0.90x0.90) sq.mtr & Door=(0.90x1.80)Sqm |
| 25 | Providing electrificaton to the Pump chamber by wiring the room with required item of materials including cost ofmaterial,labour,T& P etc. complete as per direction of Engineer-in-charge. |
| 26 | Painting and lettering of project name & PP Name over the walls with all costs |
| 27 | Cost of painting and lettering the detail salient features of project over the masanory sign board etc. complete as per direction of Engineer-in-Charge |
| 28 | Cost of Installation lowering of Submerssible pump set, delivery fitting ,electrical installation & energisation & water trial etc.with Labour Charges for cutting, threading of G.I.Pipe, cost of cosumable materials such as Nut & Bolt , Rubber Insertion,white lead paint etc. including transportation charges of T&P materials like Chain Pully Block, Tripod pipes, Chain Tounge etc. complete as per direction of site Engineer in-charge. . |
| 29 | Supply the hard copy & soft copy of 3 stage GPS & Date Photographs of the project(Pre Photographs- 3Nos, Ongoing Photographs-5nos and Post Photographs-20nos etc.complete as per direction of site Engineer in charge. |
| 30 | Earthwork in excavation of foundation in all kind of soil with initial lead and lift including rough dressing and levelling the bed and depositing the excavated materials within initial lead at nearby the worksite for reuse including breaking clods and stacking rubble for spreading and leveling as the case may be etc complete as per direction of the Engineer-in-charge. (Excavation by mechanical means 60% & manually 40%) |
| 31 | Back Filling the Pipe line trenches with excavated materials in layers not exceeding 0.30m including breaking clods within initial lead including leveling the tranches as the case may be etc complete as per direction of the Engineer-in-charge. |
| 32 | Conveyance of 160mm dia PVC pipes from stack yard to working site and Supplying all materials, labour, T&P for jointing of the same pipes as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge |
| 33 | Rigid UPVC pipe of 160 mm dia Ivory grey in colour having specific gravity of 1.4 to 1.46 Gm / CC of straight length of 6 M for portable water supplies confirming to IS 4985 / 2000 of BIS - Amendment - 2 Read with Table - I , of IS specification bearing ISI Mark for working presure of 2.5 Kgf/Cm2 as per latest amendment of ISI 4985 including cost of coupler for plain ended pipes or one end plain & other bell ended. The pipe should be tested by CIPET & each pipe should be clearly & indebile marked ink or Stenciled conforming to IS 4985/2000 including transportation and laying at site all complete. (The Rate inclusive of CIPET Testing Charges) |
| 34 | 5 HP/3.75 KW Energy efficiency Submersible pumpset of total head 25 mtr having 500 LPM discharge of reputed brand with BEE 3 Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamps & 30 mtr of 4.00 sqmm flat cable and Impeller of Bronze grade LTB-2 of IS 318/1981 confirming to IS specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 35 | Automatic Star Delta starter sheet steel enclosure suitable for operation of squirrel cage Induction motor upto 10HP (8-13) with 16. Amp (AC-3) contactor at 415 volt +6%-15%, 3 phase, 50 Hz, AC supply with suitable overload relay & No volt coil with electric pnemutic timer suitable for operation at voltage range of 300-440 volt |
| 36 | 32 AMP Triple Pole Mainswith confirming to IS No.4064(Part I & II) with ISI marking of reputed company with utilisation capacity cagegory AC- 22 of approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 37 | 3KVAR Power Shunt Capacitor with ISI mark of of reputed approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 38 | 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098 (Pt-II) of approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 39 | 80mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 40 | 80mm dia G.I.Bend ( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 41 | 80mm dia G.I.Flange (Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed company including all cost, conveyance, cess etc complete but excluding cost of GST |
| 42 | 80mm dia G.I.Socket (Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 43 | 80mm dia G.I.Nipple ( Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 44 | Cost, supplying of M.S T/W Clamp (Pair) 100mm dia with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 45 | 160 mmX110mm dia PVC Reducing Socket (6Kgf/Cm2) |
| 46 | 160 mm dia PVC End Cap(6Kgf/Cm2) |
| 47 | 160 mm dia PVC Equal Tee(6Kgf/Cm2) |
| 48 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 49 | Construction of 3 phase 4 wire Line using 8mtr long 200 kg PSC Poles with LT XLPE AB Cable of (3X35 mmSq.+ 1X25mm sq.) along with all required materials and concreting of stay/poles LT Dead end clamp, suspension clamp with I - hook, stay accessories such as Wire Insulators, clamp etc. to complete power supply as per the field condition (40m Span length) |
| 50 | Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps ,nuts & bolts, cable socket etc. including excavation of earth pits 2 Nos of size 1200mm X1200mm X 3000mm for fixing of earthing pipe 2 Nos of size 30mm dia X 3000 mm length with required slotting in pipes & fittings with 30 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work and pannel wiring with required 4mm2/2.5mm2 PVC coper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge. |
| 51 | Construction of Boundary wall of (3.60mx 3.0 )Sq.mtr around the sub station by providing 4no of 35cmx35cm pillars and rest walling with brick masonary having proper foundation as per the drawing including Sand filling and metal spreading inside the boundary , Fixing of MS grill gate of size 1.5mx1.5m with 35x35x6mm angles and 25x6mm flats etc. as per direction of Engineer-in-charge. |
| 52 | (i) Earthwork in excavation in hard soil within initial lead & lift including dressing and levelling the bed etc. complete. |
| 53 | (ii) Filling of sand in foundation and plinth well watered and rammed |
| 54 | (iii) C.C (1:4:8) using 4cm H.G metal |
| 55 | (iv) Brick work with Fly ash bricks in CM (1:6) in F&P including cost, conveyance & Royalty etc. |
| 56 | (v) C.C. (1:2:4) using 12mm HG chips at Plinth |
| 57 | (vi) 12mm thick C.P in C.M (1:6) over brick work with racking of joints |
| 58 | (vii) Filling the foundation and plinth with excavated materials |
| 59 | (viii) Cost of MS Gate with 35x35x6 mm Angle & 25 x6 mm Flat including priming & Painting etc complete |
| 60 | (ix) Metal Spreading inside the boundary Please Enable Macros to View BoQ information |