Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: HQ CWE (AF) NAGPUR Name of Work: SPECIAL REPAIR OF IF AND ASSOCIATED BAYS AT 11 BRD UNDER GE (AF) OJHAR Contract No: CWE (AF) / NGP /OJH/ OF 2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE inclusive of all taxes in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Quoted Amount in Words Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling of PVC Watertank of any capacity, any description, fixed in any position complete all as specified and as directed. |
| 3 | Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed. |
| 4 | Supply only CPVC Fittings like elbow, tee, adaptor, union, ball valve 20 mm |
| 5 | Taking down steel tubing of 15 mm dia bore and connections from walls and cellings or laid in floor including cleaning for refixing in same position (walls , ceiling, floors etc).complete all as specified and as directed. |
| 6 | Supply and fix for 20 mm dia CPVC pipe as on wall, floor, ceiling, concealed etc complete and as directed by Engr in charge with all fittings and fixtured, jonting solution of ISI mark including making grove in wall/ceiling and finished with cement mortor 1:4 with plumbing nails for securing pipes etc directed. Make: Finolex/Dutron/Ashirvad |
| 7 | Supply and fix in repair Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 8 | Supply and Fixing of P or S trap |
| 9 | Supply and fix in repair for 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle, Flush pipe of polyethylene of low or high density or PVC. 32/40 mm dia, for low level cistern including brackets complete all as specified. |
| 10 | Supply and fix in repairs Vitreous China wash basin including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, white, flat back, size 630x450mm including, waste coupling, brackets and proper and neat bonding near wall with white cement. |
| 11 | Supply and fix PVC connection 15mm size with Brass nuts, of length 600mm Complete all as specified and as directed. |
| 12 | Supply and fix 32 mm PVC flexible pipe for waste outlet with threaded socket at one end.complete all as specified and as directed. |
| 13 | Supply and fix in repairs for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 14 | Supply and fix in repairs Cast copper alloy CP angle valve type stop cock suitable for 15mm bore pipe screwed at both ends or high pressure with Capstan head confirming to Jaguar CON053 KNB or equivalent, Complete all as specified and as directed. |
| 15 | Supply and fix in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure fancy type of 15 mm bore size with or without lettered Hot or Cold with long screwed shanks and flynuts screwed for iron pipe and fixed Complete all as specified and as directed. |
| 16 | Supply and fix in repairs Cast copper alloy CP angle valve type stop cock suitable for 15mm bore pipe screwed at both ends or high pressure with Capstan head Including dismanteling and making good the tiles if required of make Prayag/Marc/Seiko, Complete all as specified and as directed. |
| 17 | Supply and fix in repairs bib tap long body foam flow with flange of bore size 15mm, cast copper alloy, chromium plated, fancy type, with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule of Prayag /Saiko/ Parko Complete all as specified and as directed |
| 18 | Supply and fix in repairs two way bib taps of bore size 15mm, cast copper alloy, chromium plated, fancy type, with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule Including dismanteling and making good the tiles if requiredComplete all as specified and as directed. |
| 19 | Supply and fix in repairs 75mm PVC (SWR) multi floor trap including jointing with solvent cement |
| 20 | Supply and fix PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement |
| 21 | Supply and fix for PVC (SWR) pipes, bore of pipe in 110mm, single socketed, in any length, with rubber ring joints, laid in floors or fixed to walls Complete all as specified and as directed. |
| 22 | Supply and fix PVC (SWR)pipe single socketed in any length with rubber ring joints, laid in floors 75mm dia Complete all as specified and as directed. |
| 23 | Supply and fix for PVC (SWR) bends/branch/Single T, any radius, bore of pipe in 110mm with cement solvent in position Complete all as specified and as directed. |
| 24 | Supply and fix PVC (SWR) 110 mm vent cowl |
| 25 | Supply and fix in repairs Brass chromium plated tubular towel rail 20mm dia 60cm long with and including flanges complete all as specified and as directed. |
| 26 | Supply and fix in repairs soap dish stainless steel as approved by GE complete all as specified and as directed. |
| 27 | Supply and fix in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass E shelf 12cm wide with chromium plated bracket guard and railing 60cm long. Complete all as specified and as directed. |
| 28 | Supply and fix in repairs Grating of 125 mm dia of stainless steel with or without waste hole Complete all as specified and as directed. |
| 29 | Material and labour for cutting into existing manhole for connecting new drains, making good to drain pipe internal dia and rendering, cutting out existing benching for and forming branch channel in cement concrete 1 :2:4 type B1 using 20mm graded stone aggregate smooth finished & reforming benching as required complete all as directed. |
| 30 | Material & Labour for concrete bed type D2 PCC 1:4:8(Using 40mm graded aggregate) to drain pipes 200 mm internal dia including packing under, and haunching against the sides of pipes after they are laid & tested dia complete all as specified and directed. |
| 31 | Material & Labour for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in man holes/ drain covers set in CM 1:6 all as specified. |
| 32 | Material & Labour for Reinforced concrete pipe, class NP-2, 200 mm internal dia laid in trenches & jointed complete with collars all as specified and directed. |
| 33 | Dismantling boarding incl wooden partition, any description, fixed in any position with screws all as specified and directed. |
| 34 | Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each all as specified and directed. |
| 35 | Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. |
| 36 | Demolition of Reinforced Concrete of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 37 | Demolition of Concrete of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 38 | Material and labour for 25mm Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) all as specified and directed. |
| 39 | Material and labour for providing Glazed Vitrified tiles 8- 10 mm thick having water absorption value less than 0.08% (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement SIurry and pointed in white or coloured cement to match including 15mm screed of 1:6 cm complete all edge specified and directed |
| 40 | Material and labour for hacking existing concrete surface for receiving the Kota Stone Flooring all as specified and directed. |
| 41 | Material and labour for Machine cut Pre-polished kota stone SIab flooring 20-25mm thick over cement screed base laid and jointed with grey cement SIurry mixed with pigment to match the shade of the SIab including rubbing and polishing complete all as specified and directed. |
| 42 | Supply and fix for PVC Laminated Gypsum tile, of size 595x595mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges, so as to make the tile a completely sealed unit, is placed in the grid. Note :- Fixing arrangements are as follows - False ceiling to be suspended on inter locking metal grid of hot dipped galvanized steel sections ,consisting of Pro1 main \\"T\\" runner of size 15.5mm x32mm x 0.3mm x 3600mm, Pro1 cross \\"T\\" of size 15.5mm x 32mm x 0.3mm x1200mm, secondary Pro1 cross \\"T\\" of size 15.5mm x32mm x0.3mm x 600mm and PPGI wall angle of size 20mm x14mm x0.4mm x 3000mm , PPGI wall angle of Finish-Galvanised 90GSM(IS277)} fixed along the perimeter of the ceiling to walls, partitions or columns etc., with wooden screws at 300mm centers. Soffit cleat 27x37x25x1.6mm is fixed with Rawl Plug- Ø8x45mm, creating 1200mm x 1200mm grid. Main-T runners are then suspended at 1200mm c/c from ceiling using 4mm zinc electroplated butterfly level clips of size 85x30x0.8mm spaced at maximum 1200mm center to center along main T and not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall. cross T of length 1200mm is interlocked between the main T at 600mm center to center to form a grid of 1200x600 mm and then secondary cross “T\\" 24x25x0.3x600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross Tees at the ends having length more than 600mm are to be supported independently. |
| 43 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 44 | Dismantling Asbestos cement /FRP sheet/GI sheet(corrugated ted, semi corrugated, etc.) sheets in roof coverings up to height 25M and taking care of earthing strip and refixing all as specified and directed. |
| 45 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 46 | Material and labour Cement concrete in foundations, filling and mass concrete Type B2 1:2:4 (40 mm graded aggregate), complete all as specified and directed. |
| 47 | Supply and fix MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 48 | Supply and fix Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for SIiding doors; fixed with angle cleats or other connecting plates Fe 410 W (GdeE- 250) qualityA |
| 49 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of AZ Value 150, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 50 | Supply and fix 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified and directed. |
| 51 | Taking down Rolling Shutter and making good surface using necessary plain cement concrete type C1 1:3:6 (20 mm graded aggregate) of any description complete as specified and directed. |
| 52 | Material and labour for Brickwork with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius,built in CM 1:6 all edge specified and directed. |
| 53 | Material and labour for 10mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement on internal surface complete all edge specified and directed. |
| 54 | Material and labour for applying two coats of oil bound distemper over and including a coat of cement base primer of same manufacturer on newly plastered walls/ceiling complete as specified and directed. |
| 55 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but backing), removing serviceable tiles to store and rubbish off the premise, complete as specified and directed. |
| 56 | Dismantling of Stone SIabs and tiles of any description or thickness in floors, aprons etc. complete as specified and directed. |
| 57 | Material and labour Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar with backing , resin type, in floors and walls all complete as specified and directed. |
| 58 | Material and labour for 1st quality non skid coloured ceramic 10-12mm thick tiles (hard standing area) exceeding 0.11 sqm but not exceeding 0.18 sqm set and jointed in neat cement SIurry & pointed with coloured cement to match in floor over and including including 15 mm thick screed bed in cement mortar (1:4) including 25 mm thick levelling corse complete all as specified and directed |
| 59 | Material and labour for heavy duty Endura vitrified tiles of thickness at least 10mm for steps, riser of size 150X1200 mm and steps for tread of size 300X1200 mm , set and jointed in neat cement SIurry & pointed with coloured cement to match in floor , over and including 15mm Screed Bed in CM 1:4 including 25mm thick levelling course wherever required, Complete all as specified and directed. |
| 60 | Material and labour for 5mm total thickness PU Flooring on concrete surface with the following specifications complete all as specified and as directed . (a) Roughening/ preparing the concrete surface substrata as required for base coat as per manufacrturer's instruction. (b) Laying of 1st coat primer (200micron) of (CIPOXY-18) with consisting of two component solvented epoxy resin based primer suitable for priming concrete surface before laying of the primer the surface drying & loose particles. (c) Material and labour for application of body coat 4.5mm thick of CIPOXY 17 with combination of base, sealant hardener mixed in ratio of base:hardner:Filler (aggregate) 2:2:8, 2kg per 1 sqm for 1 mm thickness. (d) Top coat of FK 333 300micron thick with glossy finish with covering capacity of |
| 61 | Material and labour for providing two component polyester powder coated Aluminiium shutter with similar powder coated frame 88.9mmx47.63mmx1.60 mm thick and size of shutter with top rail , middle rail and bottom rail and style of size 85 mm x 44.5 mm x 1.56 mm thick with 200 mm size powder coated 2 nos with each leaf , Heavy duty powder coated aluminium tower bolt 150mm long 2 Nos per leaf, 3 nos Heavy duty aluminium powder coated hinges of size 125mm with each leaf including 12 mm thick both side prelaminated particle board / 5.5 mm thick glass pane in the both panel with necessary joining cleats, rubber packing, aluminium beading, hydraulicc door closer ,screws etc complete all as specified and as directed Note - All fitting shall be of same finished as of door shutter door may be single/ double leaf, if the shutteris more than 1.10mtr it shall be of double leaf, the hollow section of vertical style where the hinges are to be provided the complete vertical style shall be provided with soft wood and minimum 65mm long screw provided for fixing of hinges compete all as specified as directed. |
| 62 | Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators,partition with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing,glazing clips, rubber neoprene packing, anodised aluminum snap beading screws etc fixing items , includng taking down complete existing partition etc. complete all as specified and as directed. |
| 63 | Supply and fix 5 (+/-0.5) mm thick sheet glass ordinary quality and glazing sheet glass is ground or obscured or frosted, on one side with rubber beading, fixing in aluminium frame as in partition /door as directed by Engineer in charge exc. 0.5 Sqm each pane-complete all as specified. |
| 64 | Supply and fix 12 mm thick prelaminated particle board Interior grade pre laminated both sides with decorative choice laminations fixed in partition or door ,colour as directed by Engineer in Charge on aluminium frame work all as specified and directed |
| 65 | Material and labour for repair to RCC structure using micro concrete all as per manufacturer's instructions, as described below complete all as specified and as directed :-(a) Chipping off existing loose and damaged/cracked/plaster surfaces at location decided by Engineer-in-Charge to depth not exceeding 100 mm using pneumatic tools or with chiseling & wire brushes, descale the exposed surfaces of reinforcement with wire brushes, removing all loose rust scales from rebar blowing all loose dust with blower and washing concrete surfaces. A coat of alkali rust converting primer shall be applied on the reinforcement bars.(b) Welding additional reinforcement bars where dis of existing bar is found reduced than specified limit as directed. (Reinforcement bbars shall be measured and paid separately.(c) Applying a coat of anti corrosive protective coating on both old & new reinforcement bars surfaces as per manufacturer's instructions.(d) Applying a coat of epoxy resin concrete bonding agent to exposed concrete surfaces and rebars.(e) Providing polymer modified Cement Mortar in specified composition for complying manufacturer's instructions (thickness varies from 25 mm to 100 mm)NOTES:-(i) The cost for necessary scaffolding & formwork shall be deemed to be included in the quoted rate.(ii) The work shall be carried out upto G+4 floors |
| 66 | Material and labour for complete removal of existing treatment of wall / ceiling / chajja by scrapping with mechanical trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete by skilled labour complete all as directed.Note : After Completion of Removal existing surface Approved of Engr -in- charge and GE shall be Taken before appling further finshing . |
| 67 | Material and labour for preparation of new/existing plastered surfaces of walls/ceiling/chajja and applying two coats of weather proof exterior emulsion paint over and including a coat of priming coat of exterior cement base primer as per manufacturer's instruction complete all as specified and directed.Note : (i) The painting shall be done with fully automatic airless spray machine with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats of paint.(ii) Rate quoted shall be deemed to be included for scaffolding up to 15 mtr height building. |
| 68 | Material and labour for 2 coat of 1.5 mm thick Birla Wall care putty on walls surfaces complete all as specified and as directed. |
| 69 | Material and labour for Complete Removal of existing treatment of walls/ceiling and applying two coats of oil bound distemper over and including a coat of cement base primer of same manufacturer. Note : (i) Painting shall be done using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper/ primer should be able to spray in hard to reach areas and penetration of distemper on the surface |
| 70 | Material and labour for preparation of old Chequerd tiles or paver block and applying two coat of apex tiles guard paint complete all as specified and directed. |
| 71 | Material and labour for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement SIurry and pointed in white or coloured cement to match over and including 15mm thick screed bed 1:6 complete all as specified and directed. |
| 72 | Material and labour for Glazed ceramic tiles in vertical surface 600x 300x 7-8 mm thick set and jointed in neat cement SIurry and pointed in white or colour cement to match |
| 73 | Taking down Aluminium Glass Panel along with Chowkhats & Door size of exc 1.5 sq. m but n exc 4 sq. m each complete all as specified & directed. |
| 74 | Supply and fix 12mm thick toughned glass door double leaf (each leaf size 1.00mtr x 2.10 mtr approx) Make: Saint Gobin/ Modi/Swastik or any equvilant shall be provided with monogram/logo (one logo of 11 BRD Logo and other of Airforce) by itching on glass, filling the itching with multiple colour & design or any approved by Engr-in-Charge. Film coating, making holes to glass for fixing, fixed pivet in glass door, edge polishing to glass complete all as directed . The follwing fittings rates shall deemed in this item. (1) Supply and fix for 02 Nos Double action floor spring hydraulically regulated made ISI marked make: Dorma/shivalik/royal or any equivelent of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed by Engineer in Charge. Rate shall be inclusive of all transportation, handling and taxes etc completed and as directed.(i) Supply and fix for 04 Nos 18\\" long SS Handle Make: Shivalik/dorma or any equivelent heavy duty for door all as specified and directed by Engineer in Charge.(ii) Supply and fix for SS lock for toughned glass but for single and double leaf shutter with tripple key etc completed of make Godrej/link/Royal or any equivelent etc complete all as directed. Note - Except door rest opening area is covered by Aluminium Frame with Glass.Total size is 4.00X3.00 m |
| 75 | Supply and fix 12mm thick toughned glass for door or vartical cladding or railing etc Make: Saint Gobin/Modi/Swastik or any equvilant shall be provided with monogram/logo (one logo of 11 BRD Logo and other of Airforce) by itching on glass, filling the itching with multiple colour & design or any approved by Engr-in-Charge. Film coating, making holes to glass for fixing fixed pivet in glass door, edge polishing to glass complete all as directed. |
| 76 | Providing and fixing stainless steel railing system of SS 304 grade, including stainless steel balusters, posts, clamps (clusters), brackets, glass holding studs, handrail and base supports, fixed with necessary drilling, cutting and welding, including polishing and finishing, suitable for fixing 12 mm thick toughened glass panels, complete in all respects as per architectural design. |
| 77 | Supply and fix Aluminium composite panels for outdoor use (ACP) fixed to walls /claddindgs/ facades/ canopies in any sqm geomatrical pattern /shape columns projections, chajjs, elevations or in any other positions 3 mm thick aluminium composite panel of approved colour and brand (Arrowbond/viva/Alstone/Cross bond/Eurobond of sand series or equivalent as approved) including all materials such as MS hollow rectangular section 19 gauge and size 2.5 inches and fixing at 2 to 3 feet centre to centre for base framing including scaffolding for working upto 10mtr height. The ACP shall be fixed above the MS frame/battens to the masonry/RCC walls/Facias with necessary clamps, brackets and anchor fastners. The total cost includes cost of MS frame, ACP panels, clamps, wheather sealents using silicon, gasket, forms, fixtures, scaffolding, all type of tools and plants and any other consumables like fastenings, strips, nuts bolts, rivets, washers, sealent completed and all as specified and directed. |
| 78 | Supply, install, testing, & commissioning of hi-wall split unit indoor/ outdoor complete with cordless remote control unit and inverter type with minimum 5 star rating air conditioner electric driven, single phase of capacity 1.5 TR as specified and as directed. |
| 79 | Supply, install, testing, & commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 280 V (VDI 400) with output voltage stabilized at 230 V with accuracy ± 2.5% and of capacity 4 KVA, Complete all as specified and as directed. |
| 80 | Taking down and Re-fixing the exisiting celing suspended type centrifugal Blower with starter and cable fabricated from 16 SWG thickduly powder coated sheets and plated of capacity 2000 CFM,Static pressure 60 MMWC.,Filter Velocity 2.5 m/s ,DIDW backward curved type centrifugal fan,V - belt driven GI fan with vibration Isolator,Belt guard,drain flug assembly, reinforced with angle iron for stardy and smooth performance,dynamically balanced impeller driven through electric motor shaft of 1.1 KW,4 pole,1440 RPM,3 phase,440V,ACof MAKE ABB/BBL/CG of Model NO RDH. 400R of Make: PATEL airtemp Pvt Ltd duly mounted on ISMC channel stand including making necessary electrical connections complete all as specified & as directed. |
| 81 | Supply ,assembly & erection of PGI sheet with C & SS rectangular /square duct made out of square/rectangular cross section and reuired curve shaped sas per site requirement hollow profile duly factory fabricated box including all accessories such as corner cleat,carriage bolt ,Rubber gasket & appropriate sealant on longitudinal joints,necesssary control dampers and grill embedded in PGI duct etc complete of size 24 gauge including MS supports,nut,bolts& washer,anchor fastner etc.,complete all as specified and directed. |
| 82 | Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, chain link, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces complete all as specified & directed. |
| 83 | Supply,install testing & commissioning type celing suspended type centrifugal Blower fabricated from 16 SWG thickduly powder coated sheets and plated of capacity 3000 CFM,Static pressure 60 MMWC.,Filter Velocity 2.5 m/s ,DIDW backward curved type centrifugal fan,V - belt driven GI fan with vibration Isolator,Belt guard,drain flug assembly, reinforced with angle iron for stardy and smooth performance,dynamically balanced impeller driven through electric motor shaft of 1.5 KW,4 pole,1440 RPM,3 phase,440V,ACof MAKE ABB/BBL/CG of Model NO RDH. 400R of Make: PATEL airtemp Pvt Ltd duly mounted on ISMC channel stand including making necessary electrical connections complete all as specified & as directed. |
| 84 | Supply& fix DOL starter upto 2 HP motor in sheet steel enclouser type MK-1 ( motor rating AC-3 Duty , 415 V 50 Hz 3 Ph,) and Relay range 9-14, complete all as specified & as directed. |
| 85 | Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.Note- applicable for BOQ item no 1 to 86 (a)contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative technician deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains (c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note. |
| 86 | Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed. |
| 87 | All as per above item but for One 5 Amps socket point on same/below board with other switches. |
| 88 | All as per above item but for One 5amps switch socket point independent. |
| 89 | Supply and fix in replacement Modular Socket outlet 6A Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed. |
| 90 | S&F Exhaust fan 300 mm sweep, 4 blade ( PVC ) with louvers, operated on 230/240V AC Single phase electric supply complete duly grauted bolts in the wall fixed with nuts, bolt and washers complete matching with the existing including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to exhaust fan connector complete all as per specified and directed . Make Crompton, havells , Usha |
| 91 | Supply and fix 20W Surface / Wall mounted Decorative linear 4 ft LED integrated batten made of Extruded AL Hsg channel for efficient heat dissipation & diffuser part in reeded opal finish with Decoartive end caps . High efficiency long life LED package in integral module with lumen efficacy > 130 Lm/W and viewing angle of 120° to ensure better uniformity.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. MIn System Lumen Output of 2200 lumens ( Max 20 w ) .CRI >80, Color temperature 5700K, THD < 15 % and PF>0.95,IP20 . Life class of 50,0000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV; Protection : Reverse Polarity, Open & Short Circuit. TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. As per Crompton Cat Ref: CCS-100-20-65-HL2-DP-NWH with 5 Year written warranty from manufacturer or equivalent in Havells/Bajaj/Halonix. |
| 92 | Supply and fix 10w Surface / Wall mounted Decorative linear 2 ft LED integrated batten made of Extruded AL Hsg channel for efficient heat dissipation & diffuser part in reeded opal finish with Decoartive end caps . High efficiency long life LED package in integral module with lumen efficacy > 100 Lm/W and viewing angle of 120° to ensure better uniformity.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. MIn System Lumen Output of 1000 lumens ( Max 10w ) .CRI >80, Color temperature 5700K, THD < 15 % and PF>0.95,IP20 . Life class of 50,0000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection : 2- 3 KV; Protection : Reverse Polarity, Open & Short Circuit. TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. As per Crompton Cat Ref: CCS-103-10-65-SL-DP-NWH with 5 Year warranty from manufacturer or equivalent in havells/bajaj/halonix |
| 93 | Supply and fix and connecting up LED 5 watt fitting 6500K 1 feet with 100 lumen/watt,aluminum housing extruded in thermal conductive material with powder coated in white colour Extruded serration High Optically efficient plastic FR grade material in milky white,Spring Steel Nickel plated,Inj. Moulded engineering plastic Brown in colour Five year written warranty from manufacturer including 23/00.0076 size 3 core copper flexible wire from connector to ceiling rose/adoptor including all necessary fixing arrangements complete. Crompton cat No CCS-103-05-65-SL-DP-NWH or equivalent in Philips/Havells/Wipro ). |
| 94 | Supply and fix in replacemant suspended 40 watt CONSTA LED linear lighting system suitable for continous mounting, frosted PMMA diffuser and high reflective aluminium reflector provided with surge compressor of 2.5kv to perform an erratic power condition, IP 20 CLASS I, 5700 K complete with connecting accessories & driver duly pre-wired and connecting up with 0.5 sq mm 3 core flexible copper cable cord from fitting, with suspension system as per site requirement complete all as specified and as directed by engineer in charge. Make: Havells Model No. CONSTA1144LP40WLED830SPCWH or equivalent in Cromptom/Philips |
| 95 | Supply and fix 36W LED Ultra-modern recess mounting luminaire with high performance LEDs with motion sensor, maximum 36 W 2x2 LED Panel suitable for mounting in Armstrong / 2x2 Grid ceiling which provides soft-light and glare free symmetrical illumination with CRCA powder coated Housing with sheet thickness of min 0.4 mm and with min 50 mm fixture Depth / height with glare free high translucent milky high grade diffuser with min 0.8 mm thickness . High efficiency long life LED package in integral module with lumen efficacy of >140 lm/W and viewing angle of 120° to ensure better uniformity with minimum System Lumen of 4300 Lumens with CRI > 80, Color temperature 5500- 6500 K, THD < 10% and PF > 0.95,IP20 , IK03.Life class of 50,000 hrs. @ L70, Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection: 4 KV; Protection : Reverse Polarity, Open & Short Circuit. DRIVER SAFETY REQUIREMENT STANDARDS :IS 15885-2-13, TEST REPORT TO BE SUBMITTED; PHOTO BIOLOGICAL SAFETY NORMS: IS 16108, TEST CERTIFICATE TO BE SUBMITTED; CERTIFICATION: LM 79 FOR LUMINAIRE LM 80 FOR LED SOURCE. Fixture with R mark and registration number. As per Crompton CCR-122-36-57-SL-MWS-DP-NWH with 2 Year warranty from manufacturer or equivalent in Havells/Bajaj/HalonixNote for items Nos 2 to 10: (I) To write CA nos with date of installation on each fitting (any type) with permanent marker pen . (ii) Contractor is fully responsible for replacement of unsv fitting from OEM/Dealer. (iii) All reports and test certificate of light fitting submitted by contractor before payment. (iv) The rate of T&P reqd at site for replacement of LED fitting up to 15mtr height are deemed to be included in the quoted rates. |
| 96 | Supply and fix ceilling fan BLDC 1200 mm sweep operated on 230/240V AC Single phase electric supply ,5 star with remote in white in colour complete including connecting with 3 core stranded copper conductor cable cordas as per manufacture recommendation from ceiling rose to fan connector including writing MES No. on ceiling fan white synthetic enamelled paint complete all as per specified and directed by Engr-in- Charge . Make Havelles cat pt- Efficienia Neo BLDC or equivalent in Orient n & crompton, USHA etc . incl taking down on unserviceable ceilling fan , exhaust fan any make and size from site / Hanger ( up to 15 mtr height ) and deposited the same in MES store yard for further disposal. |
| 97 | Material and labour for Machine work such as fan hook,FI clamps, nuts, bolts, washers etc duly painted complete all as specified & directed |
| 98 | Material and labour for down rod 1000 mm long for ceilling fan of any make and sweep made out of medium grade GI tubing 15 mm dia duly painted with two coats of enamel paint and provision of holes for electric wire at top and bottom also arrangemnts for fittment of ceiling fan motor,clamp assembly and condensor all specified and directed |
| 99 | Supply and fix in replacement Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor/Roma Complete all as specified & as directed. |
| 100 | Supply and fix Modular switch one way 6 Amp,1 Module , Make Anchor/Roma/Complete all as specified & as directed. |
| 101 | Material and labour for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed. (Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.) |
| 102 | Supply and fix in replacement Modular switch one way 16 Amp, 1 Module , Make Anchor/ Roma,Complete all as specified & as directed. |
| 103 | Supply and fix in replacement Modular Socket outlet 16A Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed. |
| 104 | Supply and fix Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed . |
| 105 | Material and labour wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in including PVC conduit complete all as directed . |
| 106 | Material and labour wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable including surface in wall/celling/floor in PVC conduit complete all as directed . |
| 107 | Material and labour wiring for circuit/ sub main wiring 2x4 Sqmm+1x4 Sqmm earth wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable on surface as required including in PVC casing caping complete all as specified and directed . |
| 108 | Supply and fix Sheet metal enclosure for DB’s 2 way 240 volts, Single door. Make : Standard / HPL/ Legrand, Complete all as specified & as directed . |
| 109 | Supply and fix in replacement Sheet metal enclosure for DB's SPN, with 100 amps rated bus bar 4 way,240 volts double door, Complete all as specified & as directed |
| 110 | Supply and fix in replacement Sheet metal enclosure for DB’s SPN, with 100 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed . |
| 111 | Supply and fixingTempra plug & socket with TPN having five pin plug ( 3P+N+E) & socket complete with one no MCB 32 Amp TPN, 415 V Make- Havells cat No DHDPBTN032 or Legrand Cat. Nos 507862 or equivalent make of L&T complete all as specified & as directed |
| 112 | Supply and laying LT UG cable with XLPE insulated armoured heavy duty electric power cable with aluminium conductor 1100V grade,multistanded , 4 core cross sectional area 25 sqmm as per IS 7098 ,laid in wall/ trench/duct/floor or passing through pipe all as specified and as directed . |
| 113 | Supply and fix MCB SPN 32 to 40 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed. |
| 114 | Supply and fix in replacement MCB SP 6 to 32 Amps 240 volts 10 KA C series. Cat part No-408595 Make : Legrand/ L & T./Standard ,Complete all as specified & as directed. |
| 115 | Supply and fix Switch socket combination outlet with PVC box 3 pin 16 Amps 1 flush type. Make: Anchor/Havells Rio., Complete all as specified & as directed. |
| 116 | Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including PVC casing caping not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed. |
| 117 | All as per item no 2 but for One 5 Amps socket point on same/below board with other switches. |
| 118 | Supply and fix in replacement Switch piano flush type single pole one way 5 Amp , Make Anchor/ Havells Rio,Complete all as specified & as directed . |
| 119 | Material and labour for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely. |
| 120 | Taking down old unserviceable LT cable from trench/wall/roof and re-laying the same in existing place with clamp or cable tray or in trench including all earth work (excavation involved is deemed to be included) all as specified and as directed by Engr-in-charge. |
| 121 | Supply and laying LT UG cable with XLPE insulated armoured heavy duty electric power cable with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm laid in trench/duct/floor or passing through pipe complete all as specified and directed . |
| 122 | Ditto All as per item above here-in-before above but 4 core 16 Sqmm |
| 123 | Ditto All as per item above here-in-before above but 4 core 25 Sqmm |
| 124 | Ditto All as per item above here-in-before above but 3 1/2 core 50 Sqmm |
| 125 | Ditto All as per item above here-in-before above but 3 1/2 core 70 Sqmm |
| 126 | Ditto All as per item above here-in-before above but 3 1/2 core 95 Sqmm |
| 127 | Material and Labour for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 35 to 70 Sqmm complete all as specified and directed . |
| 128 | Material and labour for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 95 to 120 Sqmm complete all as specified and directed . |
| 129 | Supply and fixing in replacement Aluminium lugs / Thimbles 95 to 120sqmm with suitable criming including all electrical connection/disconnections as required at site complete all as specified and directed . |
| 130 | Supply and fixing in replacement Aluminium lugs / Thimbles 35 to 50sqmm with suitable criming including all electrical connection/disconnections as required at site complete all as specified and directed . |
| 131 | Supply and fixing in replacement Aluminium lugs / Thimbles 16 to 25 sqmm with suitable criming including all electrical connection/disconnections as required at site complete all as specified and directed . |
| 132 | Supply and fixing in replacement GI nut, bolt, with washer of various sizes including all electrical connection/disconnections as required at site complete all as specified and directed . |
| 133 | Material and fixing of Hot dip perforated cable tray , fabricated from GI or HR sheet in standard lenght of 2.5 mtr, thickness 12 SWG , depth 75 mm width 200 mm , consisting of two longitudinal side rail connected by individual transverse member, interval of 250 mm fixing with the help of suitable size MS supports,nut,bolts& washer,anchor fastner , etc.,complete all as specified and directed . |
| 134 | Material and fixing of Hot dip perforated cable tray , fabricated from GI or HR sheet in standard lenght of 2.5 mtr, thickness 12 SWG , depth 75 mm width 300 mm , consisting of two longitudinal side rail connected by individual transverse member, interval of 250 mm fixing with the help of suitable size MS supports,nut,bolts& washer,anchor fastner , etc.,complete all as specified and directed. |
| 135 | Material and labour for cross arms, bracings, supports, clamps and back plates fabricated for cable tray from strucural steel sections of Angle iron and Iron flate steel including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as soecified, as directed . |
| 136 | Taking down old unserviceable Lt cable of size 6 sqm to 25 sqm from trench/wall/roof rectify the defects and re-laying the same in existing place including all earth work all as directed. |
| 137 | Taking down old unserviceable Lt cable of size 35 sqm to 120 sqm from trench/wall/roof rectify the defects and re-laying the same in existing place including all earth work all as directed. |
| 138 | Supply and fix in replacement Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Complete all as specified and as directed . |
| 139 | Supply and fix in replacement MCB SP 6 to 32 Amps 240 volts 10 KA C series. Complete all as specified & as directed . |
| 140 | Supply and fix in replacement MCB SPN 32 to 40 Amps 240 volts 10 KA complete all as specified & as directed . |
| 141 | Material and labour for maintainance of LT panel/feeder piller box indoor/outdoor type(of any size) by cutting corroded MS lid from panel, weilding the same with 3 mm thick./ MS sheet in any desired shape including removing the carbonised/ melted sparked thimbles cleaning the carbonised bus-bar making cable end clean, welding/ replacement of broken hinges with new one,replacement of locks with new one (as per reqiurement ) mounted on exisiting door , including taking elect shut down and cleaning the all bus bar system , incomming and out going cables,replacement of burnt thimble/caple pieces/glands by using new thimble,cleaning of MCBs/ MCCBs complete all as directed including marking of building number on front face of panel in colour as directed . |
| 142 | Note : The amount against Schedule of Credit on Page No. 49 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy