| 1 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS -H PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group-A LP-25 |
| 2 | Group-B LP-10 FP-9 |
| 3 | Group-C LP- 8 FP-8,Ex fp-5,Call bell-3 |
| 4 | Supply and fixing of 6Amp plug with 6Amp switch on existing board. (Modular type)(Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) |
| 5 | Supplying and fixing of 3 nos 6 Amp Plug point 3 nos switch, 1 No 15 Amp Switch & 1 No 15 Amp Socket Modular type on modular metal box, base & cover with all connections.(Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) |
| 6 | Supplying and fixing of 15/16 Amp Plug point Modular type on modular metal box on surface/Recess with suitable size of Modular cover in front including cutting the wall and making good the same in cases of recessed conduit as required (Make-Great white/ Legrand / Roma/ Havells/ HPL/ Cona) |
| 7 | s/f of ac point consisting of 32A starter with all connection compelete s per the direction of engineer in charge |
| 8 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 415V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.) 4(4+12) WAY DOUBLE DOOR, HORIZONTAL TYPE |
| 9 | Supplying and fixing 32Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 10 | Supply and fixing of 5Amp to 32A rating 240 V/415 V \\"c\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-Legrand /L&T/Schneider/Siemens/Hager) Single pole (SP) |
| 11 | 63 A 30 mA DX3 FP RCCB (Make-Legrand /L&T/Schneider/Siemens/Hager) |
| 12 | 63 FP MCB |
| 13 | S/F of 125 A 25KA FP MCCB with Encloser |
| 14 | Recessed wiring to submain in the following sq.mm FRLS-H PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL) 2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia |
| 15 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm -do- |
| 16 | 1x1.5 mm2 for inverter wiring |
| 17 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose . |
| 18 | s/f of tube light 18watt /20 watt led fitting with cover( Make-Havells/ Philips/Crompton as per the direction of side engineer in charge. |
| 19 | S/F Of 48\\"AC Ceiling fans including all connections and accessories of Usha Allure Dlx/Havells Pacer/Orient Summer Pride/Equivalent make. |
| 20 | s/f of 34watt /36 watt(2x2)LED round/ square surface ceiling Lights( Make-Havells/ Philips/Crompton as per the direction of side engineer in charge. |
| 21 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 22 | Supply of 6 sq mm 2 core XLPE insulated Aluminium Un Armoured cables ISI marked.(make-Havells/Polycab/KEI/Equivalent) |
| 23 | Supply of 10 sq mm 4 core Copper Armoured cables ISI marked.(Make-Polycab/Havells/KEI/Equivalent) |
| 24 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not excedding 25 sq.mm on surface as required. |
| 25 | Supply of 50 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked(Make-Polycab/Havells/KEI/Equivalent) for OLD NRC Building panel |
| 26 | Supply of 70 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked(Make-Polycab/Havells/KEI/Equivalent) DG Cable to Male ward Panel ,IPD Building 2nd and 3rd Floor |
| 27 | Supply of 95 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked(Make-Polycab/Havells/KEI/Equivalent) IPD AC Floor panel for 2nd and 3rd Floor |
| 28 | Supply of 185 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked(Make-Polycab/Havells/KEI/Equivalent) for Male ward panel |
| 29 | Supply of 400 sq mm 3-1/2 core XLPE insulated Aluminium Armoured cables ISI marked(Make-Polycab/Havells/KEI/Equivalent) for Male ward panel |
| 30 | Laying of cableLaying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required.Above 25 sq. mm and upto 120 sq. mm |
| 31 | Above 120 sq. mm and upto 400 sq. mm |
| 32 | Termination of CalesSupply & Making end Termination with brass double compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) (Make: Raychem/ M-seal/ 3M)3.5C X 50 sq. mm |
| 33 | 3.5C X 70 sq. mm |
| 34 | 3.5C X 185 sq. mm |
| 35 | 3.5C X 400 sq. mm |
| 36 | Old NRC Building-1S/F of 36x30x10 no 16/18 SWG sheet metal for main 63amp panel board having 63 amp FP MCCB 1no.,32A FP MCB 4no.,100A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 37 | Male WardS/F of 48x40x10 no 16/18 SWG sheet metal for main 400amp panel board having 400 amp FP MCCB 1no.,160 amp FP MCCB 1no.,125 amp FP MCCB 3no.,63A FP MCB,315A FP Change Over 1no.,500A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 38 | Old Building AC PanelS/F of 60x48x10 no 16/18 SWG sheet metal for main 630amp panel board having 630 amp FP MCCB 1no.,400 amp FP MCCB 1no.,250 amp FP MCCB 2no.,63A FP MCB 1no.,800A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 39 | MCH building Trf. PanelS/F of 48x60x10 no 16/18 SWG sheet metal for main 800amp panel board having 800 amp FP MCCB 1no.,1000A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 40 | IPD AC Floor Panel for 2nd & 3rd floorS/F of 54x60x10 no 16/18 SWG sheet metal for main 250amp panel board having 250 amp FP MCCB 1no.,63A FP MCCB 8no.,320A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. |
| 41 | IPD DG Panel for 2nd & 3rd floorS/F of 54x60x10 no 16/18 SWG sheet metal for main 200amp panel board having 200 amp FP MCCB 1no.,63A FP MCCB 8no.,320A electrolyte cu bus bar 1set with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), Thermal Magnetic Type. Please Enable Macros to View BoQ information |