| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and 15cm deep and getting out in soft/loose soil complete all as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil complete all as specified. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified. |
| 4 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point Complete all as specified. |
| 5 | M&L for PCC 1:4:8 type D-2 (40mm graded) as in fdn filling and mass concrete Complete all as specified. |
| 6 | M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified. |
| 7 | M&L for rendering 15mm thick cement plaster on fair faces of concrete block masnory in two layers, base layer 10mm thick in CM (1:6) and top layer 5mm thick in CM 1:4(with river sand) mixed with WPC as per manufacture' s instructions, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note :- WPC shall be measured and paid seperately Note : Water proofing compound shall be measured seprately. |
| 8 | Supply only Liquid water proofing compound |
| 9 | M & L preparation of newly surfaces of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 10 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete as specified as directed. |
| 11 | M&L for PCC 1:4:8 type D-2, 100 mm thick using (40mm graded) as sub base Complete all as specified. |
| 12 | Providing and laying vitrified parking tiles of sizes (400X400) of 10-15 mm thickness conforming to IS 15622 in all colors and shades in outdoor floors and skirting meant for parking of cars and trucks, grouting the 3 mm width joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade including filling/grouting and finishing set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete.all as specified and directed. |
| 13 | M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 14 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 15 | M & L aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering. |
| 16 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 17 | M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. |
| 18 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate finished even and smooth without using extra cement as in plinth proteaction complete all as specified and directed. |
| 19 | S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410 W (Grade E-250) quality A. |
| 20 | S & F Mild steel screw bolts (machine made) of any dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n.exc. 10 cm long complete all as directed. |
| 21 | Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed. |
| 22 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as directed. |
| 23 | Supply and fixing stainless steel powder coated bench of SS -304 grade for seating capacity of 03 person at one time of size 1800mm x 680mm x780mm all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |