| 1 | Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. |
| 2 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 3 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator / JCB) means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including getting out, dressing of sides and ramming of bottoms, lift upto 1.5 m ,returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm and removal / disposal of surplus excavated earth within lead upto 50 m , complete all as specified and direceted |
| 4 | M&L for lean cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 5 | M&L for formwork to rough finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 6 | M&L for formwork to rough finished flat surfaces of sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed. |
| 7 | M&L for formwork to rough finished flat surfaces sides of square,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 8 | M&L for reinforced cement concrete (Design Mix) M-25 in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete (Design Mix) M-25 in beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete (Design Mix) M-25 in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 11 | M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 12 | M&L for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 13 | Ditto all as per item No 12 above , but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 14 | S&F mild steel Fe - 290 Gde E- 195 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion , drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire meshetc) including all necessary drilling, bolting or riveting, etc complete all as specified and as directed. |
| 15 | S&F 3.00 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 16 | S&F structural rolled mild steel Fe - 410 W (Gde - 250) quality B framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanginggate / door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing confirming to Fe -290 Gde-E-165 complete all as specified and as directed. |
| 17 | S&F galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 18 | M&L for 20mm thick Granite (of any type) work(table rubbed and polished) in vertical surfaces , steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 19 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on other than fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for preparation of new surfaces of walls and applying two coats of cement based paint complete all as specified and directed. |
| 22 | M&L for preparation of new or previously untreated steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat primer red oxide (zinc chrome) complete all as specified and directed. |
| 23 | S&F 150 mm bore PVC(SWR) pipes in any length fixed in walls and laid in trenches or in weep holes of security / boundary wall etc complete all as specified and directed. |
| 24 | NOTE:- Drawing No. CEJZ/STD-312/2013 Sheet No. 1/1(R) for security wall (2.1 mtr high with brick wall panel) and Drawing No CEJZ/STD-305/11 Sheet No 1/5 to 5/5 for steel gate 5.00 to 7.50 mtr wide shall be for guidance and execution of work. Please Enable Macros to View BoQ information |