| 1 | Providing and fixing of 9 Mtrs long MS Decorative pole with base plate made in double section fitted with erection of the pole on provided RCC Foundation with galvanized nuts etc as required. The following specifications should be adhered for pole & accessories as desired by Engineer incharge a) Pole Top dia - 75mm b) Pole Bottom dia - 110 mm c) Thickness of sheet - 2mm d) Base plate of size - 250mm X 250 mm X 12 mm e) Set of foundation nut & bolts -4 nos EN 8 grade galavanized 600 mm length be supplied with galvaized nuts, washers, spacer plate & fixing template. The pole shall be fixed using double nuts. |
| 2 | Providing and fixing of Single arm brackt having 1200 mm length including fixing on existing MS Decorative pole etc as required. |
| 3 | Providing & fixing Alluminium composite panel (ACP) sheet sign board made of 3 mm thick, finished with approved color as back ground (color BLACK approved by department) & fixed on Existing MS Decorative pole with ms frame made of 40X25X2 mm squre pipe . LED signboard Size- 3 ft x 4 ft = 12 Sq feet including 2D solid Acrylic letters , one Kingfisher Bird Logo & BSF Monogram backlit with LED modules Life: 65000 or above burning hours, Intensity- Same & smooth throughout no bright or light or dark patches, Visibility: 100 mtr at least for normal eye, Ambient Air: 0-50c .100% relative humidity, Power consumption not more than– 1.5 watt per module (One module consists of 3 Nos of LED), LED Module- IP 66/67 protection), power supply unit- input 100-240 V AC, output- 12 V DC, 20-40 amp, fixed on ACP sheet including electricity power supply connection from existing source. Matter of signage should be uniformaly adjusted in the sign board with logo as per design and requirement. (Matter of the signage is \\"BSF CAMPUS START SPEED LIMIT 20KM /HR & BSF CAMPUS END SPEED LIMIT 20KM /HR\\" alongwith \\"Kingfisher Bird & BSF Monogram logo\\" on both side of sign board) |
| 4 | Supplying and fixing of Wedge fastner size 8 X75 mm complete etc as required. |
| 5 | Supplying and fixing of solar road stud red colour (IP 65) complete etc as required |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), ncluding dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil |
| 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more Please Enable Macros to View BoQ information |