| 1 | Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled. |
| 2 | Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as directed by the Engineer-in-Charge. |
| 3 | Removing surplus soil / spoil to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed by the Engineer-in-Charge. |
| 4 | Taking up or down the following size steel CI /DI Pipe of 150 mm dia with all necessary fittings complete from trenches all as directed. |
| 5 | All as per Item No 4.00 but of size 100 mm dia |
| 6 | All as per Item No 4.00 but of size 80 mm dia |
| 7 | Taking up or down the following size steel galvanized water tubing of 50 mm dia with all necessary fittings complete from walls / floor or trenches all as directed. |
| 8 | Taking up or down the following size steel galvanized water tubing of 40 mm dia with all necessary fittings complete from walls / floor or trenches all as directed. |
| 9 | Taking up or down the following size steel galvanized water tubing of 25 mm dia with all necessary fittings complete from walls / floor or trenches all as directed. |
| 10 | Taking up or down the following size steel galvanized water tubing of 20 mm dia with all necessary fittings complete from walls / floor or trenches all as directed. |
| 11 | Cleaning,washing,descalling the following sizes serviceable GI pipe 40 mm dia.Refixing/re-laying in same including necessary fitting/ fixture in same tranches or new location all as directed |
| 12 | Cleaning,washing,descalling the following sizes serviceable GI pipe 25 mm dia.Refixing/re-laying in same including necessary fitting/ fixture in same tranches or new location all as directed |
| 13 | Cleaning,washing,descalling the following sizes serviceable GI pipe 20 mm dia.Refixing/re-laying in same including necessary fitting/ fixture in same tranches or new location all as directed |
| 14 | Supply & Lay Ductile Iron Pipe 150mm K-9 Class Spigot & Socket type with all necessary fitting and fixture any type complete all as directed |
| 15 | Supply & Lay Ductile Iron Pipe 100mm K-9 Class Spigot & Socket type with all necessary fitting and fixture any type complete all as directed |
| 16 | Supply & fixing of GI steel tubings 80 mm dia. of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed. |
| 17 | Supply & fixing of GI steel tubings 50 mm dia. of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed. |
| 18 | Supply & fixing of GI steel tubings 40 mm dia. of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed. |
| 19 | Supply & fixing of GI steel tubings 25 mm dia. of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed. |
| 20 | Supply & fixing of GI steel tubings 20 mm dia. of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed. |
| 21 | Cutting/ Screwing existing CI/DI pipe insertion 150x100x100mm Tee, short nipple,union for branch conection of the internal pipe dia 150mm alteration or addition all as specified and as directed. |
| 22 | Material & labour for Ductile iron fittings such as bends (any type,radius , angle) tapers any type (straight,bend,increasing, decreasing or double socket etc),Tee piece,single branch Y junction double branch collar,blank flanged etc caps and plugs etc as per IS:9523-2000 of class K-12 PN -10 with internal cement mortor lining and external cement motor lining and external zinc black bitumen coated of dia 200-300 mm complete all as specified and directed. |
| 23 | M & Labour for Valve Pit Chember of size 900x900x750 mm ( Internal Dimension) with block massioary including all necessary excavation and earth work in any type of soil, returning filling and disposal of spoil to a distance .exc 50m and depositing where directed, PCC in foundation of the mix (1:4:8) type D-2 (Using 40mm graded stone cruched stone aggregate) brick mesonary 15 mm thick plaster work in CM 1:4 over all internal and external wall with white wash of both surface and MS sheet cover of suitable thickness for with hinges, equal angle iron frame and necessary locking arrangement painting of synthetic Enamel paint over coat of red oxide primer on MS Plate all as specified and directed . |
| 24 | S&F in replacement Sluice Valve CI class PN 1.6 flanged type 150mm, ISI marked with hand wheel for operation, Non- Rising SS stem, bronze body seat ring, ISI markedincluding all minor fixing arrengement complete all as directed.Make Zoloto Atr No 1079B or equivalent in Kartar/ Packs |
| 25 | S&F in replacement Sluice Valve CI class PN 1.6 flanged type 100mm, ISI marked with hand wheel for operation, Non- Rising SS stem, bronze body seat ring, ISI markedincluding all minor fixing arrengement complete all as directed.Make Zoloto Atr No 1079B or equivalent in Kartar/ Packs |
| 26 | S&F in replacement Sluice Valve CI class PN 1.6 flanged type 80mm, ISI marked with hand wheel for operation, Non- Rising SS stem, bronze body seat ring, ISI markedincluding all minor fixing arrengement complete all as directed.Make Zoloto Atr No 1079B or equivalent in Kartar/ Packs |
| 27 | Supply and fixing the Gate valve 50mm dia made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed.. |
| 28 | Supply and fixing the Gate valve 40mm dia made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed.. |
| 29 | Supply and fixing the Gate valve 25mm dia made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed.. |
| 30 | Supply and fixing the Gate valve 20mm dia made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed. |
| 31 | M&L for Cutting Existing Road incl black top cover (trench) up to 1 Mtr depth and width not exc 60cm for laying of pipe line, refilling and making good after laying of pipe with removed soil and finally sealed with cement concrete of thickness not less than 150mm to match with the top surface of Road complete all as specified & Directed. Please Enable Macros to View BoQ information |