Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : SPL REPAIRS TO POWER HOUSE, SUB STATIONS AND ADDN/ALTN TO CERTAIN B/R WORK SERVICES AT OMQs P-06 AT HQTC CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | COMMON ITEMS APPLICABLE FOR 'JOB A',& 'JOB B' |
| 3 | M&L for non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 complete all as specified and directed.Sl No 4 of job b+Sl no 22 of job a = 25+25=50 |
| 4 | M&L for glazed ceramic coloured/ digital wall tiles in vertical surface 350x250x7mm/ 450x300x7mm/ 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering on brick work or concrete surfaced wall as backing coat of cement mortar 1:4 complete all as specified and directed.Sl No 5 of job b+Sl no 23 of job a =25+40=65 |
| 5 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.Sl No 6 of job b+Sl no 75 of job a =50+150=200 |
| 6 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement. including mixing of water proofing compound wherever required as per manufacturers instructions and complete all as specified and directed.Note: (WPC shall be measured & paid separately). Sl No 7 of job b+Sl no 76 of job a =100+25=125 |
| 7 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in Cement mortar 1:6,finished even and smooth without using extra cement complete all as specified and directed.Sl No 8 of job b+Sl no 77 of job a =50+15=65 |
| 8 | M&L for preparation of new surfaces of ceiling/walls and application of two coats of cement paint over alkali resistant priming paint through mechnical means complete all as specified and directed.Sl No 11 of job b+Sl no 79 of job a =100+10=110 |
| 9 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.Sl No 14 of job b+Sl no 33 of job a =10+25=35 |
| 10 | S&F in 4.8 mm thick sheet glass ordinary quantity and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.Sl No 23 of job b+Sl no 11 of job a =12+6.9=18.9 |
| 11 | S&F PVC (SWR) floor trap 75/ 110mm dia outlet, plain/hole with grating including jointing with solvent cement complete all as specified and directed.Sl No 28 of job b+Sl no 43 of job a =2+8=10 |
| 12 | S&F PVC (SWR) bends any radius with access doors 110mm bore complete all as specified and directed.Sl No 30 of job b+Sl no 39 of job a =1+8=9 |
| 13 | S&F PVC (SWR) bends any radius with access doors 75mm bore complete all as specified and directed.Sl No 32 of job b+Sl no 38 of job a =1+8=9 |
| 14 | S&F PVC (SWR) junction single, (Single T) equal or unequal with access door 110 mm bore complete all as specified and directed.Sl No 33 of job b+Sl no 40 of job a =1+4=5 |
| 15 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation,etc or for shafts wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.Sl No 27 of job b+Sl no 41 of job a (6(c))-2+189=191 |
| 16 | ITEMS APPLICABLE FOR 'JOB A' |
| 17 | Taking down of chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from the frames) and set aside or removing from site complete all as specified and directed. |
| 18 | Taking down shutters of any description exceeding 1 Sq.m but not exceeding 2 Sq. m each and refixing in same opening after easing and adjusting complete all as specified and directed. |
| 19 | S&F for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 20 | S&F 35 mm thick factory made 2nd Class Hard wood Glazed and skeleton shutter open rebated and prepare to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc, size of members of shutters complete all as specified and directed. |
| 21 | S&F Factory Made Solid PVC Moulded Door Shutter,with particle board core , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 22 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 23 | S&F Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 24 | S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium sliding window and ventilator shutters, aluminium sections weighing not less then 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified and directed.( Note : sheet Glass and SS wiremesh shall be measured & paid separately). |
| 25 | S&F Powder coatied (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less then 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.)complete all as specified and directed.( Note : sheet Glass and SS wiremesh shall be measured & paid separately). |
| 26 | S&F in stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples including beads complete all as specified and directed. |
| 27 | Dismantling structural steel work including doors, gates and similar works but excluding framed truss etc complete all as specified and directed. |
| 28 | S&F for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 complete all as specified and directed. |
| 29 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, includingNainital or similar pattern roof coverings complete all as specified and directed. |
| 30 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hooks and bolts complete all as specified and directed. |
| 31 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hooks and bolts complete all as specified and directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 33 | M&L for 25 mm thick PCC (1:2:4), type B0 (Using 12.5 mm graded stone aggregate) as in flooring, rough finish surfaces for receving top layer complete all as specified and directed. |
| 34 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm, in floors etc. set and jointed in neat cement slurry over and including a 15 mm thick screed bed of cement mortar 1:6 and pointed with white or Coloured cement to match complete all as specified and directed. |
| 35 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm on vertical surfaces for skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar 1:4 for backing of tiles complete all as specified and directed. |
| 36 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding. 0.11 sqm, in floors etc. set and jointed in neat cement slurry over and including a 15 mm thick screed bed of cement mortar 1:6 and pointed with white or Coloured cement to match complete all as specified and directed. |
| 37 | Demolition of cement concrete(unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 38 | M&L for 75 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for hard standing including finishing the surface even and fair complete all as specified and directed. |
| 39 | M&L of Machine pressed precast conctete glossy finish interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade and pointed with grey cement mixed with pigment to match complete all as specified and directed. |
| 40 | M&L for sand cushioning of desired thickness including watering for Interlocking tiles complete all as specified and as directed. |
| 41 | M&L for coloured designed chequered cement concrete tiles of a size 400x400x25mm thick with white cement & pigment in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 42 | M&L for 15 mm thick Screed bed or bedding layer of cement mortar (1:6) for laying floor finishes all as specified and directed. |
| 43 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) including finishing the surface even and fair complete all as specified and directed. |
| 44 | M&L for Granite (of any type) tiles 18-20 mm thick [table rubbed and polished] machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone as in flooring and landings of stair case, treads including cutting and polishing of tiles over 20 mm thick screed bed of cement mortar 1:6 complete all as specified and directed. |
| 45 | All as per Item no 41.00 here-in-before but vertical surfaces with 10 mm thick rendering of cement mortar 1:4 complete all as specified and directed. |
| 46 | Taking down rain water pipes including all fittings any size and pattern upto 10th storey floors complete all as specified and directed. |
| 47 | S&F 75 mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 48 | S&F 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 49 | S&F 150 mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls as rainwater pipe complete all as specified and directed. |
| 50 | S&F PVC (SWR) junction single, (Single T) equal or unequal with access door 75 mm bore complete all as specified and directed. |
| 51 | S&F 110 mm dia,vent cowl complete all as specified and directed. |
| 52 | Taking up or down steel tubing and connection 15 mm bore pipe and removing from site complete all as specified and as directed. |
| 53 | Taking up or down steel tubing and connection 20mm bore pipe and removing from site. complete all as specified and as directed. |
| 54 | S&F for 15mm dia bore medium grade GI tubing and including all fitting ie elbow, Tee, union , tank nipple ,Coupling,etc fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed. |
| 55 | S&F for 20mm dia bore medium grade GI tubing and including all fitting ie elbow, Tee, union , tank nipple ,Coupling,etc fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed. |
| 56 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sun shades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc l0cm girth in brick walls complete all as specified and as directed. |
| 57 | Dismantling PVC water tanks 1000 ltr capacity and removing to store complete all as specified and directed. |
| 58 | S&F 1000 ltr rotational moulded polyethene water storage tank ( cylinderical verticle with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 59 | S&F 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed. (minimum weight 455 gms) complete all as specified and directed. |
| 60 | S&F gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm bore complete all as specified and directed. |
| 61 | S&F gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25mm bore complete all as specified and directed. |
| 62 | S&F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 63 | S&F in repairs fancy type 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 64 | S&F in repairs fancy type 15 mm bore angle stop valves, chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 65 | S&F in repairs PVC connection 15mm size 450mm long with CP PTMT nuts complete all as specified and directed. |
| 66 | S&F in repairs 600mm x 450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building boards on commercial ply wood including provn for hanging clips complete all as specified and directed. |
| 67 | S&F in repairs Brass chromium plated tubular towell rail 20 mm dia , D type , 600mm long between flanges fixed with & incl chromium plated brass screws and wooden /plastic cleats complete all as specified and directed. |
| 68 | S&F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed. |
| 69 | S&F in repairs standard PVC waste pipe 32mm dia.,complete for WHB complete all as specified and directed. |
| 70 | S&F in repairs PVC Flushing cistern 10 Ltr capacity valveless syphonic action type low level, white, with inlet ,ball valve float and handle including brackets and flush pipe complete all as specified and directed. |
| 71 | S&F in repairs 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 72 | S&F in repairs 100mm dia stainless steel gratings without hole /with hole of min weight 50 gms complete all as specified and directed. |
| 73 | S&F in repairs fancy type wall mount SS-304 premium grade stainless steel soap holder/stand size 11.5(l) x 8.5(b) x 5.5(h) cm fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 74 | S&F 100mm mild steel butt hinges, medium weight, cold rolled complete all as specified and directed. |
| 75 | S&F 150 mm alluminium anodised barrel tower bolts of stove enameled black, with bright bolt and fixed complete all as specified and directed. |
| 76 | S&F 200 mm alluminium anodised barrel tower bolts of stove enameled black, with bright bolt and fixed complete all as specified and directed. |
| 77 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 78 | S&F in repair 300 mm size mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 79 | S&F 75mm mild steel butt hinges, medium weight, cold rolled complete all as specified and directed. |
| 80 | S&F in repairs Powder coated fancy type Stainless Steel curtain rod 25mm dia with suitable SS brackets with suitable woodenround base and fancy type end top matching to curtain rod of make as approved by GE complete all as specified and directed. Note:[ Additional supporting bracket shall be provided if length is exceeding 1.2m and rate quoted shall include for the same ] |
| 81 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.,disposal of unserviceable materials, debris and rubbish to a distance as complete all as specified and directed. |
| 82 | M&L for Precast cement concrete block masonry with solid blocks type C1, 1:3:6 ( 20 mm graded aggregate) exc. 10 cm in width and setting in mortar 1: 6 , complete all as specified and directed. |
| 83 | Supply only liquid water proofing compound of approved quality complete all as specified and directed. |
| 84 | M&L for preparing old plastered surfaces and applying one coat of cement base paint through mechanical means complete all as specified and directed. |
| 85 | M&L for preparing new plastered surfaces of walls and applying through mechanical means two coats of oil bound distemper over a coat of alkali resistant primer over and including applying 2 mm thickness plaster of paris putty to prepair the surface even and smooth complete all as specified and directed. |
| 86 | Complete removal of existing treatment of old plastered surfaces of walls and applying through mechanical means two coats of oil bound distemper over a coat of alkali resistant primer over and including applying 1 mm thickness plaster of paris putty to prepair the surface even and smooth complete all as specified and directed. |
| 87 | M&L Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 88 | M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 89 | S & F in repair Vitreous china wash down water closet (Pedestal pattern, ETWC), white (including fixing bolts, Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 90 | M&L for PCC 1:3:6 type C1 using 20mm graded stone aggragate as in bed bricks, coping etc including weathering slightly rounded or chamfered angles and throating making grooves for fixing of man hole cover including necessary form work complete all as specified and directed. |
| 91 | Removing old dumped junk/ building materials/ debris/ tree roots, trunk, & branches of any size etc. to a distance of 30Km or beyond, out of premises of defence area, including loading, unloading by manually or by mechanical means (JCB) and to be transported through tractor-trolly or tipper and stacking at the destination complete all as specified and directed. |
| 92 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 93 | S&F Tee grid suspension system of size 600 mm x 600 mm type-1 made out of rolled framed hot dipped galvanised steel zinc coated of not less than 120 gm/sqm ,main runner shall be 0.3 mm thick of section 24 mmX33 mm cross runner 0.3 mm thickof section 24 mm x 25 mm,wall angle shall be 0.63 mm thick of section 24 mmx24 mm grid shall be suspended by 4 mm dia adjustable quick fit hanger rod ,system exposed portion shall be pre painted polyster coated in off white/white in colour complete with material,fixing, jointing etc all as per manufactures instructions complete all as specified and directed. |
| 94 | M&L Fibre cement coloured textured designer ceiling board 4mm thick of size 595x595 mm conforming to IS : 14862 & IS : 2380 Part-XIV fixed to timber / GI / Aluminium frame work with screws/clips complete all as specified and directed. |
| 95 | Taking down carefully copper/aluminium point wiring (light, fan,socket or power) complete, including fittings & fixtures such as switches, sockets,ceiling rose, pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good to disturbed surfaces with plaster & matching with the existing colour of wall/floor etc complete all as specified & directed. |
| 96 | Taking down carefully ceiling fan from ceiling, dismantaling blades, and removing fan and painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and refixing of ceiling fan in same position in serviceable condition with greasing and oiling including provision of three core 1.5 sq mm cable from ceiling rose to fan connector complete all as specified & directed. |
| 97 | M&L for point wiring with 1.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Caping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, round/ square PVC blocks at junction for batten holders, ceiling rose etc ,screws, gutti / roul plugs PVC all as per site requirements including fixing on stone walls / brick masonary walls /ceilings /floors etc and including modular sunken boxes boxes for mounting of switches/ sockets/regulator etc and 1.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as continuous earth lead connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green.and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc complete all as specified & directed for the following :- |
| 98 | One light point controlled by one single pole 5 Amps switch. |
| 99 | One ceiling fan point controlled by one single pole 5 Amps switch. |
| 100 | One exhaust fan point controlled by one single pole 5 Amps switch. |
| 101 | One 5 pin socket point 5 Amps on independent board. |
| 102 | One 5 pin socket point 5 Amps on same board with other switches. |
| 103 | All as per item No 94.00 here-in-before but for power point wiring with 2.5 Sqmm PVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volt grade cable and 2.5 Sqmm PVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volt grade cable as continuous earth lead for 6 pin 15 Amp modular switch socket outlet on independent board complete all as specified & directed. |
| 104 | S&F Modular switch , 1 Module single pole one way 10 Amps complete all as specified & directed. |
| 105 | S&F Modular socket , 2 Module 6 Amps, 5 pin, 230 volts AC complete all as specified & directed. |
| 106 | S&F Modular switch , 1 Module single pole one way 16 Amps complete all as specified & directed. |
| 107 | S&F Modular socket , 2 Module 6/16 Amps, 6 pin, 230 volts AC complete all as specified & directed. |
| 108 | S&F Modular type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm complete all as specified & directed. |
| 109 | S&F PVC ceiling rose 65 x 50 mm surface type with 3 terminals 230 volt complete all as specified & directed. |
| 110 | S&F Modular white cover plate with frame, 3 module complete all as specified and directed. |
| 111 | S&F Modular white cover plate with frame, 4 module complete all as specified and directed. |
| 112 | S&F Modular white cover plate with frame, 6 module complete all as specified and directed. |
| 113 | S&F Modular white cover plate with frame, 8 module complete all as specified and directed. |
| 114 | S&F Modular metal flush box 3 module complete all as specified and directed. |
| 115 | S&F Modular metal flush box 4 module complete all as specified and directed. |
| 116 | S&F Modular metal flush box 6 module complete all as specified and directed. |
| 117 | S&F Modular metal flush box 8 module complete all as specified and directed. |
| 118 | S&F LED Light fitting, 4 feet 1x20 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 1.5 sqmm from ceiling rose to fitting complete all as specified & directed. |
| 119 | S&F LED mirror Light fitting 2 feet, 10 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 1.5 sqmm from ceiling rose to fitting complete all as specified & directed. |
| 120 | S&F LED light fitting outdoor type 10 watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of size 1.5 sqmm complete all as specified & directed. |
| 121 | S&F LED light fitting round shape 15 watt white/warm white as per site requirement 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of size 1.5 sqmm complete all as specified & directed. |
| 122 | S&F LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of 1.5 sqmm size from ceiling rose to fitting including brackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing of street light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washers complete all as specified & directed. |
| 123 | S&F Sheet metal enclosure for DB's double door SPN, 8 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 230 Volt, complete all as specified & directed. |
| 124 | S&F Sheet metal enclosure for DB's double door SPN, 12 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 230 Volt, complete all as specified & directed. |
| 125 | S&F MCB SP, 6-32 Amps, 230V, C- series with breaking capacity of 10KA complete all as specified & directed. |
| 126 | S&F MCB SPN, 40 Amps, 230 V, C- series with breaking capacity of 10 KA complete all as specified & directed. |
| 127 | S&F Sheet metal enclosure for DB's double door VTPN 04 ways including 01 No MCCB 125 Amp 4 pole to be used as incomer and outgoing as MCB single pole, deep drawn with 200 Amps rated copper bus bar 415 V, complete all as specified & directed . |
| 128 | S&F Exhaust fan steel body AC single phase 230 V of size 380 mm sweep, 900 RPM with blades, and frame and louvers including making holes in brick/stone wall of suitable size dia for fixing of exhaust fan and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc complete all as specified & directed . |
| 129 | S&F BLDC ceiling fans complete with blades, down rods, electronic regulator and accessories, AC single phase 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) and remote to control all the function of fan complete all as specified & directed. |
| 130 | S&F Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece and including drilling holes in any type wall fixing four nos anchor bolts five inch size,nuts and washer and connected to water pipe line with two nos hot and cold 600 mm long connection pipe and electric connection testing complete all as specified & directed. |
| 131 | M&L for sub main wiring with two single core 2.5 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Caping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 2.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed.Notes-Two run of 2.5 sqmm single core cable and one run of 2.5 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 132 | M&L for sub main wiring with two single core 4.00 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Caping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 4.00 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed . Notes-Two run of 4.00 sqmm single core cable and one run of 4.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 133 | M&L for sub main wiring with two single core 6 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Caping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed.Note-Two run of 6.00 sqmm single core cable and one run of 6.00 sqmm earth wire including PVC casing & capping together shall be measured as one unit. |
| 134 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI protection pipe 15 mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed.Note: (i) The unit rate includes 15 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes galvanised iron wire 4 mm dia from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained (iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. |
| 135 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing 4 mm dia galvanised iron or steel wire complete all as specified & directed. |
| 136 | Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed. |
| 137 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 138 | M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed.Note- Punned thickness of sand i.e 18 cm shall be considered for measurement purpose. |
| 139 | Supplying and laying un-reinforced precast concrete cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed. |
| 140 | M&L Plain cement concrete 1:2:4 type B1(using 20mm graded crushed stone aggregate) as in benching,coping including weathering slightly rounded or chamfered angles or as per site requirement with necessary plastering work complete all as specified and directed. |
| 141 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 70 sqmm 3.5 core and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified and directed. |
| 142 | All as per item No 133.00 here-in-before but of size 95 sqmm 3.5 core. |
| 143 | All as per item No 133.00 here-in-before but of size 120 sqmm 3.5 core. |
| 144 | S&F in replacement MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 145 | S&F in replacement MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 146 | S&F in replacement MCCB, 4 poles 415 Volts, 350 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 147 | S&F in replacement MCCB, 4 poles 415 Volts, 400 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed. |
| 148 | Supply and Install on load Changeover switch 415 Volt in sheet metal enclosure 4 pole of capacity 200 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed. |
| 149 | Supply and Install on load Changeover switch 415 Volt in sheet metal enclosure 4 pole of capacity 400 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed. |
| 150 | S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of 2.5 sqmm size from ceiling rose to fitting including street light brackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing of street light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washers complete all as specified & directed. |
| 151 | S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connecting up with three core flexible copper conductor cable of 2.5 sqmm size from ceiling rose to fitting and bracket complete all as specified & directed. |
| 152 | S&F street light brackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing of street light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washers complete all as specified & directed. |
| 153 | Disconnecting and taking out old rusted pipe and M&L 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including new Flat Iron clamps=02 Nos of size 40x5mm, made to shape including nut bolt and washers complete all as specified & directed. |
| 154 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron strip of size 32 x 6 mm as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI protection pipe 40mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed.Note: (i) The unit rate includes 40 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes GI main earthing lead/strip of size 32x6 mm from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained (iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. |
| 155 | S&F GI strip 32 x 6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length on roof/wall of building/ connect to LT panel or main DB and joining the same with existing earth test point complete all as specified & directed. |
| 156 | M&L for Earthing complete with copper earth plate of size 600x600x3.15mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to copper strip of size 20x3 mm as earth lead up to test point with suitable size copper coating nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hinged and frame of angle iron 25x25x6mm with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI earth wire protection pipe 40mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed. Note: (i) The unit rate includes 40 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes copper main earthing lead/strip of size 20x3 mm from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 2 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained .(iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. |
| 157 | S&F copper strip 20mm X 3mm with saddles and fixing screws on porcelin insulator/ spacer fixed at every 1 mtr length on roof/wall of building/ connect to LT panel or main DB and joining the same with existing earth test point complete all as specified & directed. |
| 158 | M&L for Loose filling with aggregates of gauge 40 mm filling in Sub Stn area as per ground availability of area, cleaning the area, removing vegitation,debries in Sub Stn making level, and filling the aggregate complete all as specified & directed. |
| 159 | ITEMS APPLICABLE FOR 'JOB B' |
| 160 | M&L 40 mm thick PCC (1:2:4), type B0 (Using 12.5 mm graded stone aggregate) as in flooring,finished even and smooth w/o using extra cement complete all as specified & directed. |
| 161 | M&L Virified Ceramic tiles 10 mm thick jointless (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. set and jointed in neat cement slurry over and including 15 mm thick screed bed of cement mortar 1:6 and pointed in white/ coloured cement to match complete all as specified & directed. |
| 162 | All as per item No 153.00 here-in-before but as in wall skirting over and including 10mm thick rendering of cement mortar 1:4 complete all as specified & directed. |
| 163 | M&L fo Rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:3 in ceiling of chajja,roof projection,shelve etc and finished even and smooth without using extra cement complete all as specified & directed. |
| 164 | M&L preparation of new surface for application of two coats of distemper oil emulsion in wall surfaces white or tinted through mechnical means over a coat of 1mm thick wall care putty,complete all as specified & directed. |
| 165 | Dismantling stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified & directed. |
| 166 | M&L for 20mm thick Granite of any type work (table rubbed and polished) in cooking plateform, widow sill and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade granite incl 15mm thick screed bed in cement mortar 1:6 complete all as specified & directed. |
| 167 | S&F 12mm thick plywood 7 ply with BWR type BB, fixed with adhesive and screws as in shutters and partitions of working tables/ shelves/ wall mounted shelves, trolley mounted racks complete all as specified and as directed. |
| 168 | M&L for 0.90mm thick decorative laminate type I of surface finish(colour & pattern as approved) fixed with approved adhesive as per manufacturers instruction finished to approved size for working tables/ shelves/ wall mounted shelves of any shape of any pattern and design etc complete all as specified and as directed. |
| 169 | S&F Mild steel nickel coated telescopic drawer slider with ball bearing, one inch size, 18 inch long two beam max load capacity 35-40kg suitable for working table, drawer on and size and any pattern complete all as specified and as directed. |
| 170 | S&F of Cutlary Drawer Length420mm, Depth-485mm, Height-100mm made of stainless steel of Grade IS:202 complete all as specified and as directed. |
| 171 | S&F Plain basket Drawer Length420mm , Depth-485mm, Height-100mm made of stainless steel of Grade IS:202 complete all as specified and as directed. |
| 172 | S&F Thali basket Drawer Length420mm, Depth-485mm, Height-150mm made of stainless steel of Grade IS:202 complete all as specified and as directed. |
| 173 | S&F 6\\" premium quality Handle, \\"complete all as specified and as directed. |
| 174 | S&F Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 175 | M&L for Bathroom Vanity set with WHB size 710x450x200mm Water proof cabinet size of 680x440x400mm, Looking Mirror size of 700x50mm and Side Cabinet size of 250x150x700mm, of any design or shade complete all as specified and as directed. |
| 176 | M&L for Venetian Image LED Bathroom Mirror with Light, Antifog Backlit Design, Touch Control, Dimmable Lighting (Three Colour), Horizontal Vertical wallMount Modern Bathroom Decor. (Size of Mirror 40\\"L x32\\"W) and fitting of any design or shade complete all as specified and as directed. |
| 177 | S&F Toughned glass of 12mm thickness as in hinged doors, partitions automatic door and similar work including cutting to shape, drilling holes with required fittings and other requirements such as stainless steel runners and fittings all required complete all as specified and as directed. |
| 178 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 179 | S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail