Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws all as specireid and directed including dismantling the unserviceable sheets, complete all as specified and directedNOTE : While dismantling of roof sheets much care must be taken to ensure that no khatamband/ceiling, wall panelling beneath damaged and if damaged then the same should be repaired at contractors end. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws all as specireid and directed including dismantling the old unserviceable sheets, complete all as specified and directed. |
| 3 | S&F galvanised mild steel sheeting1mm thick , in ridge, hips , valley gutter, drips and straight flashings (Length and girth as fixed ) with grade of zinc coating 275, complete all as specified and directed |
| 4 | S&F galvanised mild steel sheeting 0.63mm thick , in ridge, hips , valley gutter, drips and straight flashings (Length and girth as fixed ) with grade of zinc coating 275 complete all as specified and directedincluding dismantling the unserviceable old sheets, complete all as specified and directed. |
| 5 | S&F galvanised mild steel sheeting 0.63 with two corrugation side lap , fixed with coach screw or self tapping screws and washers as in roof covering/ wall clading etc with grade of zinc 275 complete all as specified and directed including dismantling the old unserviceable sheets, complete all as specified and directed. |
| 6 | Refixing of shutters including taking down easening and adjusting and also refixing hardware as required including renewal of unserviceable screws etc. of any description exc 1.0 sqm but n exc 2.0 sqm each, in same opening, complete all as specified and as directed. |
| 7 | Taking down frame with shutters (without taking off shutters from frame) n.exc 1.5 sq.m each, complete all as specified and directed. |
| 8 | Taking down frame with shutters (without taking off shutters from frame) exceeding 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed |
| 9 | M&L for 2nd class hard wood solid , straight chowkhats and frames , wrought framed rebated on th solid , rounded or chamfered put together with glue pinned at joints supplied and fixed complete all as specified and directed |
| 10 | S&F 30mm thick 2nd class hardwood factory made glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed |
| 11 | S&F 35mm thick 2nd class hardwood Plain framed panelled shutters two(panelled) with lock rail and 9mm B.W.P commercial ply 12mm veneered particle board with commercial veneering on both face. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressed treated fixed to chowkats, complete all as specified and directed |
| 12 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples etc., complete all as specified and directed. |
| 13 | S & F but hinges heavy weight , cold rolled mild steel 100 mm size, complete all as specified and directed. |
| 14 | S & F 150 mm size extruded aluminium handles fabricated type, anodised, complete all as specified and directed. |
| 15 | S & F 150 mm size aluminium anodised barrel tower bolts of extruded sections, complete all as specified and directed. |
| 16 | S&F Aluminium alloy , anosidsed, sliding door bolt with hasp, staple 300 mm long and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts extruded section or cast aluminium alloy with complete locking arrangement, all as specified and directed |
| 17 | M&L for preparation of new wooden or previously untreated wooden surfaces of any description over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed |
| 18 | M&L for timber framed and fixed wrought Second class hard-wood in scantlings frame work including dismantling the old Unserviceable scantling Complete all as specified and directed. |
| 19 | M&L for 2nd hard wood Plain fillets square, rectangular or tirangular in section exc 3sqcm but not exc 6 cm sqm clean swan secured with nails or brads etc., complete all as specified and directed |
| 20 | M&L for brickwork with old sized subclass 'B' bricks straight or curved on plan exc 6m mean radius and built in CM 1:6 etc including demolition of brick work or stone built in cement mortar, complete all as specified and directed. |
| 21 | M & L for rendering 10mm thick cement plaster in CM (1:6) on brick work or concrete surfaces finished even and fair without using extra cement including taking down cement plaster in any mortar, complete all as specified and directed. |
| 22 | M & L for rendering 15mm thick cement plaster in CM (1:4) on brick work or concrete surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 23 | M & L for rendering 5mm thick cement plaster in CM (1:3) on brick work or concrete surfaces finished even and fair without using extra cement, complete all as specified and directed. |
| 24 | M&L for Preparing newly Plastered Surfaces of internal wall and applying two Coats of Plastic emulsion paint over and including 3 mm thick wall care putty on wall plastered surface, complete all as specified and as directed. |
| 25 | Material and labour for preparation of newly plastered surfaces of ceiling including pilasters,cornics etc and applying two coat of oil emulstion distemper over and including1 to 2mm thick wall care putty, complete as specified and directed |
| 26 | M&L for preparation of new plastered serfaces of walls for applyingTwo or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt reistance exterior all weather paint of required shade (company Depot Tinted) with silicon additives 1.43 litres/10Sqm over and inluding priming coat of exterior primer applied @ 0.90/10 Sqm over and including 3mm thick wall care putty new surfaces, complete all as specified and directed. |
| 27 | M&L for preparation of old plastered serfaces of walls by brooming down or with steel wire brushes scrapping down smoke soot moulds, moss and efflorescent salts trading oil and greasy spots etc and applyingTwo or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt reistance exterior all weather paint of required shade (company Depot Tinted) with silicon additives 1.43 litres/10Sqm over 3mm thick wall care putty & inluding priming coat of exterior primer applied @ 0.90/10 Sqm, complete all as specified and directed |
| 28 | M&L for preparation of stone wall surfaces and applying grey stone colour including making good to disturbed pointing over stone work and applying two or more coat of exterior all weather platic emulsion paint on raised poting, complete all as specified and directected. |
| 29 | M&L complete removal of existing treatment preparation old plastered surfaces of wall and applying One coat Plastic emulsion paint over and incl 3mm thick wall care putty complete all as specified and directed |
| 30 | M&L for complete removal of existing treatment preparation old plastered surfaces of ceiling and applying One coat plastic emulstion paint over & incl 3 mm thick wall care putty, complete all as specified and directed |
| 31 | M&L for preparation of old painted wooden surface and wood based materials of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 32 | M&L for preparation of old painted steel & iron surfaces of any description over 10cm width or girth and applying one coat synthetic enamel paint, complete all as specified and directed |
| 33 | M&L for preparation of old un painted steel and iron surfaces of any description over 10cm width or girth and applying two coats synthetic enamel paint, complete all as specified and directed |
| 34 | M&L for French polishg on surface of any descriotion , width or girth cleaning and preparation the surfaces including a coat of wood filler on new/old surfaces with two or more coats, complete all as specified and directed. |
| 35 | M&L for preparation of old plastered wall surfaces by washing down , brooming down or steel wire brushing etc and applying One coat Cement Base paint, complete all as specified and directed. |
| 36 | M&L preparing new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc. to previously untreated steel surfaces in roof and applying two coats of synthetic enamel paint (tinted), complete all as specifed and directed. |
| 37 | Material and labour for 20- 25 mm thick machine cut kota stone flooring 20 to 20 mm thick over cement screed base laid and jointed with neat cement slurry mixed with pigment to match the shade of the slab laid over 20 mm thick bedding layer in cement mortar 1:6 including rubbing and polishing complete all as specified,Including Dismantling floor, hearth or wall tiling, complete all as specifriedf and directed. |
| 38 | M&L for coloured glazed tiles with 3mm spacers on vertical surface size excedding 0.16 Sqm but not exceeding 0.54 sqm each tiles 7 to 8mm thick set and jointed/grouting in neat cement slurry and pointed in white or colour cement to match the shade of tiles including 10mm thick (Plaster) backing coat in CM 1:4, including dismantling floor, hearth or wall tiling built in any cement mortar etc., complete all as specified and directed. |
| 39 | M&L coloured Vitrified tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not esx 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in CM 1:6, including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) etc complete all specified and directed. |
| 40 | M&L coloured Vitrified tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not esx 0.36 Sqm, as in skirting, dados, walls, vertical surfaces etc., set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles including 10mm thick backing coat in cement motor 1:4, complete all as specified and directed. |
| 41 | M&L 18-20mm thick granite (telephonic black) work (table rubbed and polished) in Washbasin counter sunk, pillars, window-cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick screed bed or bedding layer in CM(1:4) including dismantling old floor, hearth or wall tiling including cement mortar bedding (but not backing) etc., complete all as specified and directed. |
| 42 | M&L 18-20mm thick Marble (green ) work (table rubbed and polished) in Washbasin counter sunk, pillars, window-cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick screed bed in CM(1:4) including dismantling old floor, hearth or wall tiling including cement mortar bedding (but not backing) etc., complete all as specified and directed. |
| 43 | M&L for grinding mirror like finish of Kota /Granite/Marble in any situation in any position under following steps:-(i) Clean the floor and fill joints or gaps with cement slurry or stone glue to allow the surfaces to dry completely.(ii) Using flooring grinding machine with course diamond pads of 30, 60 and then 120 grit stone.(iii) Applying medium to fine grit pads (200 to 800 grit)(iv) Applying 1000 to 3000 grit damond pads for refine finishing applying cream with buffing machine for shine, finally applying crystallizer chemical with steel wool pad on single -disc machine for mirror finishing complete all as specified and directed. |
| 44 | S&F 110 mm dia PVC (SWR) pipes including necessary bends, fittings etc single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. |
| 45 | S&F 75 mm dia PVC (SWR) pipes including necessary bends, fittings etc single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.. |
| 46 | S&F PVC(SWR) branch piece single (Single Y) equal or unequal 110mm, complete all as specified and directed. |
| 47 | S&F PVC(SWR) branch piece single (Single Y) equal or unequal 75mm, complete all as specified and directed. |
| 48 | S&F PVC(SWR) bends any radius 110mm, complete all as specified and directed. |
| 49 | S&F PVC(SWR) bends any radius 75mm, complete all as specified and directed. |
| 50 | S&F in repairs 15mm bore stop valves or angle valve, fancy type chromium plated primium quality screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc(make Jaguar or equivalent), complete all as specified and directed. |
| 51 | S&F in repairs 15mm bore Bib taps, chromium plated, fancy type premium quality , screwed down, screwed for iron pipe or for brass ferrule etc., complete all as specified and directed. |
| 52 | S&F 1000 litres capacity three rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including brass float valve, gunmetal valve etc complete all as specified in SSR Part I including dismantling PVC water tanks exc 500 litres and not exc 1000 litres capacity etc., complete all as specified and directed. |
| 53 | S& F in repair 75 mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement to waste pipe , complete all as specified and directed. |
| 54 | S&F in repairs brass chromium plated Tubular towel rail 20mm dia complete all as specified and directed. |
| 55 | S&F Towel Ring of stainless steel fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms), complete all as specified and directed. |
| 56 | S&F flush pipe of ployethelene of low high density or PVC 32mm dia for washbasin etc outlet pipes, complete all as specified and directed. |
| 57 | S&F100mm dia Cast iron Nahni trap including jointing to waste pipe fixed plain cement concrete type B-1 (1:2:4) using 20mm graded crushed stone aggregate, complete all as specified and directed. |
| 58 | Removing safely and refixing in repair Vitreous China wash down water closet one piece pan (Pedestal pattern), (including all fitting all fixing bolts reqd to reset in its original place), complete all as specified and directed . |
| 59 | S&F Vitreous China wash down water closet one piece pan (Pedestal pattern), white/colour (including all fitting all fixing bolts, flushing cistern, jet spray and flush pipe), complete all as specified and directed |
| 60 | S&F Touchless Sensor urinal pot primium quality with automatic flushing accessaries including all fittings and fixtures, complete all as speified and directed. |
| 61 | S&F PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and directed. |
| 62 | S&F in repairs vitreous china counter top wash basin with fixing accessories, oval /rectangular shape white of size 595x420x200, including 32mm brass chromium plated waste coupling(and cast iron brackets incl all fitting accessaries, complete all as specified and directed. |
| 63 | S&F in repairs Toilet paper holder chromium plated, box type with chromium plated (CP) brass screws, complete all as specified and directed. |
| 64 | S&F in replair Premium quality centre hole basin mixer oval shape or approved shape for mixing hot & cold water, suitable for wash hand basin, cast copper alloy , chromium plated, fancy type, screwed down, high pressure with lettered Hot & Cold with long screwed shanks and fly nuts, screwed for iron pipe, suitable for 15mm bore, complete all as specified and directed. |
| 65 | S&F 3 layer PPR Polypropylene random co polymer concealed pipes of 20mm outer dia SDR7.4 (PN16) UV stabilied and antimicrobial fusion welded having thermal stability for hot & cold water supply inclduing all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors including taking down old GI steel tubing, complete all as specified and directed |
| 66 | S&F 3 layer PPR Polypropylene random co polymer concealed pipes of 25 mm outer dia SDR7.4 (PN16) UV stabilied and antimicrobial fusion welded having thermal stability for hot & cold water supply inclduing all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors complete including taking down old GI steel tubing, complete all as specified and directed . |
| 67 | Dismantling wrought iron or mild steel work of any description, complete all as specified and directed. |
| 68 | S&F for Framed brackets of angles, flats or tees with web and flanges, tubular pipes cut to shape,drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 69 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed including dismantling the old boardings, complete all as specified and directed |
| 70 | S&F 5mm thick pvc sheet fillet of width 35mm for wall panneling inclusive of fixing on to wall to make pvc frame as per specification and drawing, complete all as specified and directed. |
| 71 | S&F in repairs for wooden laminated flooring in strips of size 120 cm long and 20 cm wide and 6-8 mm thick, fixed with PVC sheet and cushion including fillets/cornices, laid over 12mm thick BWR plywood including dismantling complete all as per manufracturer's instruction, complete all as specified and directed. |
| 72 | S&F khatamband pattern false ceiling, design as approved by GE with ornamental wood work made out of 1st class soft wood (Deodar) including fillets/cornices and 12mm thick BWR plywood and finally finishing with french polish (Two or more coats) including dismantling wall and ceiling boards (fibre, pulp, insulation, etc.), complete all as specified and directed.(Assuming 25% of Celings of 1st floor only) |
| 73 | S&F 10-12mm thick 1st class softwood wooden(Australian) panelling fixed with tounged and grouted a wall panelling and including fillets/cornices and 9mm ply wood fixing on wall and two coat of warnishing, polishing and prerparation with sneezing including dismantling wall and ceiling boards (fibre, pulp, insulation, etc.), complete all as specifiedf and directed. |
| 74 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,all as per architectural drawings complete all as specified and directions of Engineer-i-n Charge. |
| 75 | S & F of Powder coated aluminium of any colour (Thickness of powder coating not less than 50 micron ) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including providing and fixing hinges/pivots and making provision for fixing of fittings whereever required ,necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as door stopper double leged (1 No.). hinges type B-21 125mm long (3 Nos.) suitable handles 2 Nos including Mortice lock arrangment and frosted glass 5.5mm thk in upper panel and 12mm thick Prelaminated decorated on both face Particle board sheet in lower Panel .) for each shutter complete all as specified and as directed. |
| 76 | S&F Powder coating of any colour (Thickness of powder coating not less than 50 micron ) Anodised aluminium window and ventilator(Three Track window) including frame for sliding shutters & fixed pane over sliding window with frame and sliding aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handle ,Tower bolt & locking arrangement, 4mm thick glass( Tinted) of selected quality in two shutter and mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples etc in one shutter etc., complete all as specifried and as directed. |
| 77 | S&F in repair 4 mm thick sheet glass Tinted/frosted selected quality and glazing with aluminium & rubber beading in squares/rectangular window panes etc., complete all as specifiedand directed |
| 78 | M&L 6mm thick Non Asbestos fibre cement /Pre Laminated self embosssed texture designer board E-Board classic size 600x600mm, HPSC (High pressure steam cured) to be fixed or inserted to pre laminated GI frame work for seamless ceiling size 600mm x 600mm with main runner 38x24x0.9mm thick, cross tee 8.6x24x0.9mm and wall angle 19x19x0.9mm duly suspended with 6mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including dismantling the old ceiling, complete all as specified and directed. |
| 79 | S&F cobble stone flooring of size 100x100x50mm over 75mm thick PCC 1:3:6 type C2 (using 20mm course agg) and 20 thick screed bed in CM 1:6 and gaps to be properly grouted with epoxy solvent etc., complete all as specified and directed. |
| 80 | M&L 2nd class hard wood weather boarding desiner type on one edge as in eaves board etc and fixed with nails /screws including necessary scaffolding reqd to fix the same the edges of roof ) 25mm thick and rebated on thick edge to give 20mm laps and fixed on ceiling or any other position including dismantling of old boarding and applying two coat of synthetic enamel paint over a coat of pink primer. complete all as specified and directed. |
| 81 | M&L 2nd class hard wood weather boarding 25mm thick , wrought both sides, V-joints to give 20mm laps as in repairs to replace old or decayed boardings in patches,including cutting out old , piecing, eading joints etc and removiding dismantled boarding to stores as in ceiling and fixed with nails /screws including necessary scaffolding reqd to fix the same complete and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 82 | M&L for plain cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding 50mm thick in average mixed with water proofing compound 2 to 3% or as instructed by manufaturer, including dismantling old plain cement concrete any thickness, complete all as specified and directed |
| 83 | M&Lfor plain cement concrete 1:2:4, type Bo (using 20 mm graded crushed stone aggregated) as in coping/ benching to manholes and drains including necessary form work, complete all as specified and directed. |
| 84 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. |
| 85 | M&L for Making single phasing point wiring system used as copper conductor wire for phase and neutral wiring system the wire made out of PVC insulated FRLS of 1100 volt grade with having multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) ISI marked drawn through wiring system surface on wall or concealed in wall with the help of heavy duty ISI mark PVC casing capping strip / PVC conduit pipe ISI mark in any lengthy wiring system and along with its all connected fittings accessories including providing of pressed steel terminal sunken boxes or heavy duty PVC box and duly fixed it concealed in wall or surface on wall and alongwith providing of back and face top covered plate frame or electro plated plastic laminated sheet for housing / mounting of any type/size switches sockets, regulators etc and including using /drawing of one run of single wire 1.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI marked with multistranded copper conductor wire used as a continuous earth wire for point wiring complete system and including making the good to all disturbed surfaces of wall/ceiling area of new wiring system and to match to it as per the existing surface of wall/ceiling etc for the following, complete all as specified & directed. |
| 86 | one light point / fan point wiring system controlled by one way switch, complete all as specified and directed. |
| 87 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board , complete all as specified and directed. |
| 88 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board, complete all as specified and directed. |
| 89 | Description all as per serial item No 85 but using PVC insulated FRLS wire 1100 volt grade with multistranded copper conductor wire of size 2.5 Sq. mm (Nominal area) ISI Marked for power socket point on indenpent board point wiring system and also providing of 2.5 sqmm PVC insulated FRLS wire 1100 volt grade ISI Marked with multistranded copper conductor wire used as a continuous earth wire for power point wiring system, complete all as specified and directed. |
| 90 | Supply and fixing of modular type switch 5/6 Amps 220 Volts AC,one module, complete all as specified and directed. |
| 91 | Supply and fixing of modular type socket of 5/6 Amps 220 Volts AC, 3/5 multi pin type with two modular, complete all as specified and directed. |
| 92 | Supply and fixing of modular type switch of 15/16 Amps 220 Volts AC one module, complete all as specified and directed. |
| 93 | Supply and fixing of modular type socket of 15/16 Amps 220 Volts AC 5/6 multi pin type with two modular, complete all as specified and directed . |
| 94 | Supply and fixing ceiling rose three terminals type made out of polycarbonate , isolated body complete all as specified and directed. |
| 95 | Supply and fixing star rated electric wall mounted fan 400 mm sweep of single phase 230 volt AC with having pull cord oscillating type single piece AS blade, three speed pull cord control complete with blade and guard framing support & connecting accessories and fixed/grouting on wall/roof with MS fastner, nut & bolt including providig flate flexible copper wire and making all electrical connection, complete all as specified and directed. |
| 96 | Supply anf fix in repair LED Security light luminaire fitting of 1x35 watts with deep drawn housing including all accessories with suitable 40 mm dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts, complete all as sepcified and as directed. |
| 97 | Supply and fixing LED mirror picture wall light 3 in1 color changing light fitting with high out put diffuser 2' long and with aluminium chanel environmental friendly of 12 Watt 220 volt AC decorative type with driver holder and LED lamp with having energy efficient type complete light fitting set and including providing of suitable type flat flexible cable for electric connection from ceiling rose to fitting and making electric connection and including taking down of old existing fitting, complete all as specified and directed. |
| 98 | Supply and fixing of LED tube light fitting of 1x 20W/22W 220V AC decorative box type with driver, holder including LED tube light with having energy efficient type use in both warm/white type colour complete including providing of suitable type flate fexible cable for electric connection from ceiling rose to fitting comlplete fitting, complete all as specified and directed . |
| 99 | Supply and fixing recessed/ceiling concealed/Surface mounted down lighter light fitting of round/Square flate shapes decorative type with high efficiency PMMA fiffuser soft glare free light with drivers & LED luminaire of rating capacity in 15Watt to 18Watt 220 volt AC complete light fitting set all as per existing fitting type/ size of sample /model and make and including making in cutting or additional extra corner cutting work on existing hole of ceiling surface (when if required at site) for setting & fixing of new light fitting complete including making in additional extra corner cutting work on existing hole of ceiling surface (when if required at site) for setting & fixing of new light fitting complete and also providing of suitable type of flate fexible two/three core cable and makong electric connection and including taking down of old fitting, complete all as specified and directed. |
| 100 | Supply and fixing of sheet metal enclosure duly powder coated with double pole and neural enclosure with a two pin and earth plug and top and having mounting chanel and complete with one 01 MCB SPN 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed on wall and making good the disturbed wall surface all as required at site, complete all as specified and directed . |
| 101 | Supply and fixing of sheet metal enclosure duly powder coated with Triple pole and neural enclosure with a three pin and earth plug and top and having mounting chanel and complete with one 01Triple Pole MCB 32 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed on wall and making good the disturbed wall surface all as required at site, complete all as specified and directed . |
| 102 | Supply and fixing of sheet metal enclosure duly powder coated with double pole and neural enclosure with a two pin and earth plug and top and having mounting chanel and complete with one 01 MCB SP 20 Amp and making all necessary electrical connection and dully fixed surface on wall or concealed on wall and making good the disturbed wall surface all as required at site, complete all as specified and directed . |
| 103 | Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type of distribution board of rating SPN 8 way type 220 volt AC supply system and having neutral and earth link bus bar and mounting base chanel suitable for holding MCBs incommer and s outgoing system complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical and also refixing the electric meter and its wiring connection including taking down of existing meter and DBs, complete all as specified and directed. |
| 104 | Supply and fixing of MCB SPN 40 to 63 Amps with breaking capacity 10KA 'C' Curve series, 220 Volts, 50 Hz AC supply complete and also making suitable size / type of electric wiring coneenection, complete all as specified and directed |
| 105 | Supply and fixing of MCB SP 06 to 32 Amps with breaking capacity 10KA 'C' Curve series, 220 Volts, 50 Hz AC supply complete and also making suitable size / type of electric wiring coneenection, complete all as specified and directed. |
| 106 | Supply and fixing Exhaust fan, Plastic body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and making hole of any size on wall or wooden frame work for fixing of wall fan all as specified and directed. |
| 107 | Supply and fixing of ventilating exhaust fan made out of complete sturdy engineering Metal body with having motor ,frame louvers & shutter and blade suitable for of size 450 mm 230 Volts including making of suitable type /size of hole on wall etc., compete all as specified and directed. |
| 108 | S & F Storage type Water heater (Geyser) 5 STAR of Cap 25 Ltrs working on 230 volts AC supply with in and out going water connection pipe (Hot & Cold) fixing arrangement with nut bolts and making good the disturbed surface and including taking down old Geyser of any capacity carefuly and deposite in safe custody of MES store, compete all as specified and directed. |
| 109 | Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type for vertical type distribution board vertical loadline type of rating VTPN 4 way type 415 volt 3 phase AC supply holding system with IP protection rating with ISI marked and having fitted neutral and earth link bus bar and mounting base chanels and blanking plates suitable for holding of main MCCB as incommer and out going MCB complete system alongwith providing and mounting in side of DB box of 01 No of MCCB TP 160 Amps with breaking rupting capacity 25 KA and having adjustable setting type and also providing of 08 Nos of MCB SP 63 Amps 10KA 'C' curve type of the same manufacture make as per of distribution board make complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical and also refixing the electric meter and its wiring connection including taking down of existing meter and DBs, complete all as specified and directed. |
| 110 | Supply and fixing of Sub main wiring system with two runs PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size 2 Run of 10 Sqmm and 1 Run of 10 Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy duty ISI mark PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old unservicable sub main wiring system complete and making good all disturbed surfaces match to the existing surface complete all as specified and directed . Note: 3 runs of 10 Square mm copper cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 111 | Supply and fixing of Sub main wiring system with two runs PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size 2 Run of 4 Sqmm and 1 Run of 4 Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy duty ISI mark PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old unservicable sub main wiring system complete and making good all disturbed surfaces match to the existing surface, complete all as specified and directed . Note: 3 runs of 4 Square mm copper cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 112 | Supply, laying and testing of LT cable XLPE insulated screened,PVC bedded galvanized steel strip or wire armoured electric power cable ( heavy duty ) with aluminium conductor 1100 volt grade cross section area of size 35 sqmm 3.5 core including laid in trenches or fixing on poles or passing through pipes complete including taking out of old unserviceable cable any type any size, complete all as specified and directed . |
| 113 | M&L for earthing work complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level and connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of galvanised steel and to be protected by GI pipe 15 mm bore light grade & connected to earth test point/main switch board or main control board and also providing charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil all as shown in Electrical Plate No 3 of SSR part -I. and also making arrangment of 20 mm dia bore galvanised iron pipe (medium grade) for water and making funnel, wire mesh,and also including provision of concrete pit cover framing work in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) with top concrete pit cover and handle for lifting of cover, complete work all as specified and directed |
| 114 | Notes :-An amount of Rs 1,41,114.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail