| 1 | Providing & installation of single phase submersible motor pump set & laying of G.I. pipe line in varrious place at ward no. 33 Zone 03 |
| 2 | Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4\\"/6\\" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope. Make - Kirloskar, falcon, Texmo, Luby & any ISI standard make)3 HP Head Mt. 119-45 Discharge LPM 25-90MPPHED SOR Ist Sep. 2023, 11.2/P-164 |
| 3 | Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. Use for service control cable (meter to panel)4.0 Sq.mm.multi strand11.5/P-165 |
| 4 | Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part II. Medium 40 mm. dia.3.1.5/P-47 |
| 5 | Providing and fixing gun metal/ brass check (non-return) valves Class-II, female ends, tested to 21.09 kg/sq.cm. Screwed 25mm diaUADD SOR VOL. - I 2nd Aug. 20216.8.3/P-90 |
| 6 | Providing and fixing G. I. Bend 90 degree in G.I. Pipe line i/c cutting threading testing etc. complete (Old work) 25mm dia6.27.3/P-95 |
| 7 | Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade, 2 core/3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor ARMOURED 2 Core 10 Sq.mm.(XLPE)UADD SOR VOL. - IV 2nd Aug. 202114.1.2.4/P-78 |
| 8 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50Cycle, 10 kAValue AC supply confirming to IS: 8828 : 1996, IEC: 60898:2002 but without enclosures DOUBLE POLE (DP) 6 Amp to 32 Amp Rating8.5.3.2/P-41 |
| 9 | Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200. UADD SOR VOL. - I 2nd Aug. 202118.12/229 |
| 10 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed All kinds of ordinary soil18.2.1/P-227 |
| 11 | Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.18.2.8/P-228 |
| 12 | Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate 18.14.3/P-229 |
| 13 | Providing laying and jointing of galvanised Iron Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete./Medium6.1/P-88 |
| 14 | 15mm dia |
| 15 | 32mm dia |
| 16 | Providing and fixing full way gate valves tested to 21.00 kg/sq.cm./Screwed6.3/P-88 |
| 17 | 15mm dia |
| 18 | 32mm dia |
| 19 | Providing and fixing class-I Globe wheel valves, tested to 21.09 kg/sq.cm./Screwed6.5/P-89 |
| 20 | 15mm dia |
| 21 | 32mm dia |
| 22 | Providing and fixing gun metal/ brass check (non-return) valves Class-II, female ends, tested to 21.09 kg/sq.cm./Screwed6.8/P-90 |
| 23 | 15mm dia |
| 24 | 32mm dia |
| 25 | Providing & fixing water taps/Stainless Steel 15mm dia6.17.1/P-92 |
| 26 | Providing and fixing G.I. Union in G.I. pipe line including cutting and threading the pipe and making long screws etc complete (new work) :6.22/P-93 |
| 27 | 15 mm diameter pipe. |
| 28 | 32 mm diameter pipe. |
| 29 | Providing and fixing G. I. socket in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.25/P-94 |
| 30 | 15mm dia |
| 31 | 32mm dia |
| 32 | Providing and fixing G. I. Bend 90 degree in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.27/P-95 |
| 33 | 15mm dia |
| 34 | 32mm dia |
| 35 | Providing and fixing G. I. Tee in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.29/P-96 |
| 36 | 15mm dia |
| 37 | 32mm dia |
| 38 | Providing and fixing G. I. Elbow in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.31/P-96 |
| 39 | 15mm dia |
| 40 | 32mm dia |
| 41 | Providing and fixing G. I. Nipple of minimum length 100mm in G.I. Pipe line i/c cutting, threading, testing and carriage etc. complete (Old work)6.33/P-97 |
| 42 | 15mm dia |
| 43 | 32mm dia |
| 44 | Providing and fixing wrought steel Cap Plug with threading in G.I. Pipe line testing etc. complete (New & Old Work)6.35/P-98 |
| 45 | 15mm dia |
| 46 | 32mm dia |
| 47 | Providing and fixing G. I. Cross with outer threading in G.I. Pipe line i/c cutting threading testing etc. complete6.37/P-98 |
| 48 | 15mm dia |
| 49 | 32mm dia |
| 50 | Providing & installation of single phase submersible motor pump set & laying of G.I. pipe line in varrious place at ward no. 25 Zone 03 |
| 51 | Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4\\"/6\\" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope. Make - Kirloskar, falcon, Texmo, Luby & any ISI standard make)3 HP Head Mt. 119-45 Discharge LPM 25-90MPPHED SOR Ist Sep. 2023, 11.2/P-164 |
| 52 | Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. Use for service control cable (meter to panel)4.0 Sq.mm.multi strand11.5./165 |
| 53 | Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part II. Medium 40 mm. dia.3.1.5/P-47 |
| 54 | Providing and fixing gun metal/ brass check (non-return) valves Class-II, female ends, tested to 21.09 kg/sq.cm. Screwed 25mm diaUADD SOR VOL. - I 2nd Aug. 20216.8.3/P-90 |
| 55 | Providing and fixing G. I. Bend 90 degree in G.I. Pipe line i/c cutting threading testing etc. complete (Old work) 25mm dia6.27.3/P-95 |
| 56 | Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade, 2 core/3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor ARMOURED 2 Core 10 Sq.mm.(XLPE)UADD SOR VOL. - IV 2nd Aug. 202114.1.2.4/P-78 |
| 57 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50Cycle, 10 kAValue AC supply confirming to IS: 8828 : 1996, IEC: 60898:2002 but without enclosures DOUBLE POLE (DP) 6 Amp to 32 Amp Rating8.5.3.2/P-41 |
| 58 | Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200. UADD SOR VOL. - I 2nd Aug. 202118.12/229 |
| 59 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed All kinds of ordinary soil18.2.1/P-227 |
| 60 | Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.18.2.8/P-228 |
| 61 | Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate 18.14.3/P-229 |
| 62 | Providing laying and jointing of galvanised Iron Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete./Medium6.1/P-88 |
| 63 | 15mm dia |
| 64 | 32mm dia |
| 65 | Providing and fixing full way gate valves tested to 21.00 kg/sq.cm./Screwed6.3/P-88 |
| 66 | 15mm dia |
| 67 | 32mm dia |
| 68 | Providing and fixing class-I Globe wheel valves, tested to 21.09 kg/sq.cm./Screwed6.5/P-89 |
| 69 | 15mm dia |
| 70 | 32mm dia |
| 71 | Providing and fixing gun metal/ brass check (non-return) valves Class-II, female ends, tested to 21.09 kg/sq.cm./Screwed6.8/P-90 |
| 72 | 15mm dia |
| 73 | 32mm dia |
| 74 | Providing & fixing water taps/Stainless Steel 15mm dia6.17.1/P-92 |
| 75 | Providing and fixing G.I. Union in G.I. pipe line including cutting and threading the pipe and making long screws etc complete (new work) :6.22/P-93 |
| 76 | 15 mm diameter pipe. |
| 77 | 32 mm diameter pipe. |
| 78 | Providing and fixing G. I. socket in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.25/P-94 |
| 79 | 15mm dia |
| 80 | 32mm dia |
| 81 | Providing and fixing G. I. Bend 90 degree in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.27/P-95 |
| 82 | 15mm dia |
| 83 | 32mm dia |
| 84 | Providing and fixing G. I. Tee in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.29/P-96 |
| 85 | 15mm dia |
| 86 | 32mm dia |
| 87 | Providing and fixing G. I. Elbow in G.I. Pipe line i/c cutting threading testing etc. complete (Old work)6.31/P-96 |
| 88 | 15mm dia |
| 89 | 32mm dia |
| 90 | Providing and fixing G. I. Nipple of minimum length 100mm in G.I. Pipe line i/c cutting, threading, testing and carriage etc. complete (Old work)6.33/P-97 |
| 91 | 15mm dia |
| 92 | 32mm dia |
| 93 | Providing and fixing wrought steel Cap Plug with threading in G.I. Pipe line testing etc. complete (New & Old Work)6.35/P-98 |
| 94 | 15mm dia |
| 95 | 32mm dia |
| 96 | Providing and fixing G. I. Cross with outer threading in G.I. Pipe line i/c cutting threading testing etc. complete6.37/P-98 |
| 97 | 15mm dia |
| 98 | 32mm dia Please Enable Macros to View BoQ information |