| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable In surface/ recessed steel conduit, with modular switch, moduler plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conducter single core cable etc. Group B (Make - Havells/Polycab/HPL/equivalent) |
| 2 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVBC conduit 2x 1.5 sq.mm +1x1.5 sr.mm earth wire (Make - Havells/Polycab/HPL/equivalent) |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC Insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit 2 X 2.5 sq.mm + 1 x 2.5 sq. mm earth wire(Make - Havells/Polycab/HPL/equivalent) |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit 2 x 4 sq.mm + 1x4 sq. mm earth wire(Make - Havells/Polycab/HPL/equivalent) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit 2x6 sq.mm + 1x6 sq. mm earth wire |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC6 Insulated copper conductor, single core cable in surface/recessed medium class PVC conduit 4 x 16 sq.mm + 2 x 6 sq. mm earth wire(Make - Havells/Polycab/HPL/equivalent) |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate 15/16 A switch(Make - Havells/Anchor/equivalent) |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate 6 pin 15/16 a socket outlet(Make - Havells/Anchor/equivalent) |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate 5/6 A switch(Make - Havells/Anchor/equivalent) |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate 3 pin 5/6 A socket outlet(Make - Havells/Anchor/equivalent) |
| 11 | SITC of GI Strip 25 x 3 mm (ISI Marked) |
| 12 | SITC of Chemical Earthingwith 14.2 mm Copper Earthing Pipe 3mtr length |
| 13 | SITC of Lift Panel with suitable bus bar for operating 433V SOKz 3 Phase 4 Wire Powder coated dust & burn proof fabrication of steel body having 2mm thickness. The panel shall contain voltmeter, ampere meter, indicators, selector switches & CT Set of required capacity & 4-Pole MCCB 160A - 01 Nos, 35 KA 4-Pole = 01 Nos, 4-Pole Front Loading Change Over 125 Amp- 01 No, TPN 63 Amp =03 Nos, SPN 40 Amp = 02 Nos, SPN 63Amp = 01 No. (complete Job) |
| 14 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes 3Module |
| 15 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCBdistribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, 1 interconnections, powder painted includlng earthing 4 way (4 + 12), Double door |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles In the existing MCB DB complete with connections, testing and commissioning Single pole (Make: Havells/equivalent) |
| 17 | Supplying and fixing 5A to 32 A rating, 240/415V, 10KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles In the existing MCB DB complete with connections, testing and commissioning Triple pole and neutral (Make: Havells/equivalent) |
| 18 | Supplying and fixing following rating, double pole, 240 V, Isolator In the existing MCB DB complete with connections, testing and commissioning 63 A (Make: Havells/equivalent) |
| 19 | Supply & fixing bulk head with 9W LED Bulb |
| 20 | SITC of Exhaust Fans for new wash rooms 12\\" Size (Heavey Duty) (Make Havells / Bajaj / Crompton) |
| 21 | SITC of Copper Wound 1200mm Ceiling Fan with double ball beaming (Make Havells / Bajaj I Crompton) |
| 22 | SITC of LED Tube Light with batten type flttting 20Watts (Make - HPL / Havells I Crompton I Phillips/ Wipro) |
| 23 | SITC of 3-Phase 25KVA Copper Wound Servo Controller Automatic Voltage Regulator 3-Phase unit indoor type voltage Range:295-465 V or Specified by the customers. Output Voltages:400 V +/-1% (Can be set anywhere between 3801-415V) Output Voltage Regulation : +1% of set coltage over the specified input range from no laod ro full load ( Oil Cooled) Make Eletric field (Equalant) |
| 24 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections modular plate (Make: Havells/equivalent) |
| 25 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note: Vertical type MCB TPDB is normally used where 3 phase outlets 12 way (4 + 36), Double door Please Enable Macros to View BoQ information |