| 1 | Supply of 11 mtr high PU Painted octagonal galvanised GI steet light pole with made out from 3mm thick steel sheet (grade of steel S-355) Top dia 90mm & Bottom dia 210 mm single sharp welding with base plate dimension 300x300x16 mm, 4 nos. of M24X750 long 'J' type EN 8 grade foundation Bolts,PCD 300mm. and wind speed of 180 km/hr.The door opening of the pole should be reinforced,water proofed & with locking arrangement hinged type (special for theft control) &Supply of junction box with 1nos 6Amp SP MCB & terminal box with provision for connection of earth & nutral on 5mm thick fiber plate which will be kept in side the pole for termination of cable & wire. .Provision should be made for fixing of junction box inside the pole door copmpartment,4nos foundation bolts (galvanised)should be supplied with pole. (galvanization of the pole is as per BSEN ISO 1461 & minimum galvanization thickness is 75micron) (To be given on one side only with approximate spacing of 30 mtr)(Make-RR Ispat /BAJAJ/Valmont/Utkarsh/Vakrangee/Transrail )NB: The structural design of the pole foundation shall be approved by concerned civil wing( SE, Keonjhar (R&B) Division)/competant authority. |
| 2 | Supply and fixing of PU Painted GI decorative double tappered single arm 2000mm bracket with decorative FRP canopy & Frp decorative knobs, the arm design should reflect heritage of Keonjhar as per the direction of Engineer-in-charge. The contractor should submit various combinations of Arm & Pole design to the Engineer-in-Charge after award of contract and before procurement for approval. |
| 3 | Supply of LED Design based BIS approved LED Street Light with system power of 220W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >34100 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light engine and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS)NB: LM79 reports of the light fixture from third party/central/state govt accredited NABL lab is to be submitted and duly approved from SE(Electrical circle) R&B. Alongwith the above said reports, the LUX design report, LUX level design for road carraigeway to be done as per following specifications: average lighting level shall be >=41 LUX , Uniformity >=0.6 , Maintenance factor of 0.85 to be considered, LUX level design for pedestrian side-1 to be done as per following specifications: average lighting level shall be >=25 LUX , Uniformity >=0.6 , Maintenance factor of 0.85 to be considered, LUX level design for pedestrian side-2 to be done as per following specifications: average lighting level shall be >=36 LUX , Uniformity >=0.6 , Maintenance factor of 0.85 to be considered, the lighting level should be uniform and there should be no dark patches. Accordingly, the optics of luminaire and pole should be designed ,Technical data sheet of light are also to be submitted for approval from SE(Electrical circle) R&B. After supply of material, a random sample will be chosen and will be sent to Govt. NABL approved lab for destructive test for verification of genuinity of all the reports.If the product does not comply with the reports submitted, the whole lot will be rejected.Cost of the testing shall be borne by the contractor. |
| 4 | Supply of 1.1 KV, AYFY 4C x 16sqmm Aluminium Armoured XLPE Cable through clamping /HDPE pipe in complete as per the direction of Engineer-in-charge. Make-Havells/KEI/Finolex/Polycab/Gloster/RR Kabel |
| 5 | Supply and laying of 63mm HDPE PN16 pipe at a depth of 1m (underground) required for cable laying in complete as per the direction of Engineer-in-charge. |
| 6 | supply and laying of class-C GI pipe 100mm dia (required for road crossing of main cable) in complete as per the direction of Engineer-in-charge. |
| 7 | Supply of 1.1 KV, AYFY 3.5C x 35 sqmm Aluminium Armoured XLPE Cable through cable trench/HDPE pipe in complete as per the direction of Engineer-in-charge. Make-Havells/KEI/Finolex/Polycab/Gloster/RR Kabel (transformer to control feeder pillar) |
| 8 | Foundation & erection of 11mtr long street light pole and the foundation drawing is to be designed so as to sustain wind speed of 180km/hr and the same shall be duly approved by SE(R&B) Division, Keonjhar. |
| 9 | Wiring of make 3 core 1.50 mm2 round flexible copper cable from junction box to light fitting in complete as per the direction of Engineer-in-charge. Make-Havells/KEI/Finolex/Polycab/Gloster/RR Kabel |
| 10 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required. |
| 11 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE/METAL pipe as required.. |
| 12 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,02 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials. |
| 13 | The earthing rod should be 1853mm long fabricated from 20mm dia rod with hot dip galvanised. The earthing arrangement should consist of GI bolt/nut and washers. |
| 14 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 15 | Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthing as required. |
| 16 | Supply & transportaion of GI L-plate Size ( 350x350x12MM & 350x350x12MM) & TOP PCD 275mm & side PCD for wall part 300 PCD. Bolt size 4x24mm dia I-bolts with height 200mm with 5nuts & wahers. Supply of 4nos chemical anchore nolts HIT-V 8.8 GRADE GI I type bolts M20x 350mmlong with 4mos nut bolts & washers with fixing RE-500 chemicals . |
| 17 | Supply & transportaion of I bolts 4nos 700 mm with 3nuts & washers along with pole holding GI clamps 2sets for additional support. |
| 18 | Supply ,installation,testing and commisioning of 16M high mast shaft in two sections Material construction S355 grade as per BS EN 10025,Base dia & top diameter (A/F) Top: 150 mm | Bottom: 540 mm,Plate thickness Top: 4 mm | Bottom: 5 mm, Cross section of mast 20 side polygon, Standard of galvanisation As per BS EN ISO 1461,Size of opening and door at base 1200 x 250 mm, Diameter of base plate 720 mm,Thickness of base plate 30 mm,Lightning protection finial GI single spike, Max wind speed 300 Km/hr as per IS 875 (Part III), Number of foundation bolts 12 Nos, PCD of foundation bolts 650 mm, Type / diameter / length of foundation bolts TS 600 / 30 mm dia / 850 mm long, LUMINAIRES CARRIAGE , Material of construction 50 NB ERW Class B MS Pipe, Diameter of carriage ring 711 mm (ID),Construction 8 Arm, Welded, 2 Sections, Load carrying capacity 16 Luminaire, TRAILING CABLE , Conductor Copper, 5 Core, 4 sqmm, Insulation EPR insulated, PCP sheathed, No of circuits per mast 1 No cable per mast, WINCH / POWER TOOL , Type / SWL of winch DDMFO 750 Kg (20/6), Method of operation, Integral Motor, Motor capacity 1.5 HP, No of speeds 6 Pole, Single speed, STAINLESS STEEL WIRE ROPE , Grade / construction AISI 316, 7/19, Number of ropes 2, Nos continuous,Diameter 6 mm, Breaking load capacity 2350 kg x 2 suitable for 300 km/hr wind speed along with head frame, luminaires carriage suitable for 8 luminaires in symmetrical arrangement and other accessories manufactured in factory.Supply of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial.Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.Supply of LED type single dome aviation obstruction light. (Make-RR Ispat /BAJAJ/Valmont/Utkarsh/Vakrangee/Transrail ) |
| 19 | Construction of shallow foundation with M20 grade concrete for high mast considering SBC of 5 T/sqm at 2 m depth including all materials, labour, excavation, PCC, RCC, anchor bolts and complete as required Erection of high mast using suitable tools & plants including wiring of luminaires with 1.5 sqmm PVC insulated copper flexible cable, lugs, MCB and all labour complete Provision of chemical copper bonded earthing with 2.5 m long, 40 mm dia electrode (250 micron) including GI strip 25x3 mm connection to mast complete (2 Nos per mast) |
| 20 | Supply of 400W LED Floodlight in CCT 5700K, CRI greater than 70, SDCM less than 3, LED with Life of L70 @50,000 Hours, the system lumens more than 58000 lumens (System Efficacy >145 lpw). Powder coated by corrosion resistant nano technology powder coating. Luminaire must be minimum IP66 and IK08. The fixture should have an UV stabilized injection moulded special PC and UV stabilized injection moulded special PC compound lens of best in class uniformity. Glass cover not allowed. Luminaire housing and optical compartment (lens/lens cover) both should carry OEM's logo embossed/engraved (no stickering is allowed). The driver compartment and optical compartment should be separate and must be isolated with a natural air gap for better thermal management. The luminaire must have integral encapsulated high efficiency electronic thermally isolated driver having aluminium extrusion construction with rated voltage of (100-300V), power factor greater than 0.95, THD less than 10%, with inbuilt surge protection of minimum 6kV and upgraded with integrated IP67 protected SPD of 20kV/10kA surge protection with all necessary safety protection like mis-wiring, over voltage, short circuit, reverse polarity protection. The driver compartment should be bottom openable for ease of maintenance at site. Following documents to be submitted along with bid: luminaire and driver TDS, photometry report, type test certificate, IP, IK, vibration and salt spray test certificates from NABL accredited laboratory, LM80 report with luminaire OEM watermark, CE certification, design registration document, ROHS compliant, BIS certificate for luminaires mentioning manufacturing facility of OEM, BIS of driver. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS) |
| 21 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,02 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials. Please Enable Macros to View BoQ information |