|
| 1 | Earthwork in excavation of foundation of structures of culverts,abntments piers, retaining walls etc. in all types of Strata comprising of any of the materials such as soil, silt, sand, clay, gravel, murrum of all varieties, shingles, pebbles, all types of conglomerates, laterite rock etc soft rock, ordinary rock or disintegrated rock, fissured shattered /decomposed rock or weathered rock all such other materials as described under Appendix 'A' to these specifications either in full or in parts as the case may be adopting mechanical means (hydraulic excavator) or any approved method or methods as the case may be convenient or permitted inclusive of blasting, chiseling and wedging etc. in all conditions such as dry, moist,saturated, submerged, foul condition etc. and as directed by the Engineer-in-charge all complete including dressing of sides ramming of bottom including all leads and lifts including getting out the excavated soil as directed barricading danger lighting guarding and the departmental officers as per drawing and technical specification, including setting out construction of shoring and bracing removal of stumps and other deleterious matte, dressing of sides and bottom, back filling the excavation earth to the extent required and utilising the remaining earth locally for road work upto 3.00 m depth as per MORTH Specification 304 EXCLUDING DEWATERING. Ordinary Soil Meachanical Means. |
| 2 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 3 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 mm nominal size) excluding cost of centering, shuttering and finishing : a)All works upto plinth level . |
| 4 | Centering & shuttering including Strutting, Propping & removal of forms for : i)Foundations, Footings, Bases for columns. |
| 5 | Providing and laying 50mm(consolidated thickness)full grout using granitic or basaltic stone of specified grading at 6.00 cu.m. per 100 sq.m. grouting with hot bitumen straight run bitumen(or with such bituminous material of grade and type as specified by the Engineer-in-Charge)at 5.0kg. per sq. m. binding with key aggregate of granitic or basaltic stone of specified grading at 1.5 cu.m. per 100 sq.m. including Providing and laying seal coat sealing the voids in a bituminious surface laid with F.E loader with 1 Cu.m. bucket capacity to the specified levels, grade and cross fall using Type A seal coat with 0.98 kg/sqm of bitumen of grade as per MoRT&H specifications clause 513. |
| 6 | Providing and applying tack coat with bitumen grade of 80/100 or bitumen emulsion using pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom as per MoRT&H specifications clause 503.Bitumen 80/100 @ 0.20 kg/sq.m |
| 7 | Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects) for Grading-I ( 13 mm nominal size ) |
| 8 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35. The finished surface to be level uniform and free from streaks and holes as per MORTH Specification 803 |
| 9 | Providing & fixing of facility information sign board of size 600mmx800mm rectangle made out of retro reflective sheeting conforming to Type XI standards of ASTM D4956-09 & as per IRC-67: 2012 specifications, fully covered over 4mm thick ACP/2mm thick Al supported with back support frame of 35x35x5 mm mild steel angle. Board Shall be fixed to a vertical post of 75x75x6mm mild steel angle of 3.6 mtr height and firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm etc, 60 cm below ground level. 10 years warranty & a certified copy of three years outdoor exposure report from an independent lab as per IRC 67-2012 for Type XI retro reflective sheeting shall be submitted by the contractor. * to be procured through GHRSSIDC and the same shall be released on submission. |
| 10 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. * size 900 x 4004 x150mm with steelreinforcement not less than 7kg per unit-30T capacity * to be procured through GHRSSIDC and the same shall be released on submission. |
| 11 | Add 1% labour cess Please Enable Macros to View BoQ information |