| 1 | [10.73]Providing and fixing ceramic and Glazed tiles/ vitrified tiles/ of any size of approved make in floors / dados, laid in any pattern as specified over base of 3 mm thick adhesive of reputed brands as per IS specification 15477-2004 using 5 Kg. adhesive per sqm area of tiles and jointed with white cement slurry mixed with pigment to match the shade of tiles excluding cost of tiles. |
| 2 | [22.210.4]Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm |
| 3 | [28.11]`Supplying and installing 1.5 mm thick SBS membrane, self-adhesive polymer modified bitumen comprising of a cross laminated HDPE carrier film. Membrane shall come with a BBA certification giving a durability of membrane up to the life of the structure and shall have Tensile Strength : L: 215N/50mm T: 220N/50mm ( as per BS EN12311-1), Elongation : L: 324% and T: 238% (as per BS EN12311-1), Water Vapour Permeability : Impermeable to ISO 12572 (as per BS EN 1931), Resistance to Hydrostatic Head: Min 60m( as per ASTM D5385), Adhesion to primed concrete : 4.9mm (as per ASTM D1000). The surface shall be primed using Bituminous Primer and membrane shall be installed with an edge lap of 50 mm and end lap of 150 mm. Membrane Termination shall be done by providing a groove cut of 30mm x 30mm, put the membrane inside the groove, nailing of aluminium flashing at 200mm c/c and sealing with a suitable PU Sealant at the termination of waterproofing membrane at minimum of 300mm height on the vertical wall, as per the manufacturer’s Specification. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding for protection board.` |
| 4 | [28.23]Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 5 | [29.5]Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 6 | [5.43.1]Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1. For thickness of tiles 10 mm to 25 mm |
| 7 | [8.3]Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. |
| 8 | [9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board |
| 9 | Supply and installation of 10 KVA/360V Emergency rescue device (ARD) battery back up including wiring and making all interconnection with all accessories complete in all respect. |
| 10 | Supply and installation of 180 AH 24V DC Battery bank including wiring and making all interconnection with all accessories complete in all respect Please Enable Macros to View BoQ information |