Tender For Repair/ Replacement Of Street/ Security Lights, Painting Of Poles And Allied Works In Zone C & D At Mil Stn Raiwala Under Age (I) Raiwala, Raiwala-Uttarakhand
TDR : 55248629
Tender Notice
BOQ
19 Days Left
Raiwala
Uttarakhand
Tender For Repair/ Replacement Of Street/ Security Lights, Painting Of Poles And Allied Works In Zone C & D At Mil Stn Raiwala Under Age (I) Raiwala
Name of Work:- REPAIR/ REPLACEMENT OF STREET/ SECURITY LIGHTS, PAINTING OF POLES AND ALLIED WORKS IN ZONE C & D AT MIL STN RAIWALA UNDER AGE (I) RAIWALA
Sl. No.
Item Description
1
Supply and fixing in repair 45 W LED street lights, IP 66 & IK07 protected, housing made of powder coated single piece pressure die cast aluminium with heat dissipation housing with toughened glass cover and secondary lens on each LED & should be SMD type. The System Luminaire efficacy >= 120 lm/watt with High power LEDs is to be used and potted driver must be potted & has a unique BISR number with input voltage AC 140 V to 270 V AC with High voltage Cut off @ >= 300 V AC and auto resetting safety Input Frequency 50 Hz ± 3 % , Power factor > 0.95 driver Efficiency > 85 %, THD (I) < 10 %, humidity 10 % to 90 % RH, CRI >70, Working Temp -10 C to 50 C. The Luminaire shall be BIS certified and T.C certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70 % lumen maintaned and CCT 5700 K+335K. Surge protection shall be min>= 4 KV internal and min 10 KV external.Note-: The manufacture should provide warranty of street light for 2 years. Please Enable Macros to View BoQ information
2
Supply and fixing in repair 45 W LED street lights, IP 66 & IK07 protected, housing made of powder coated single piece pressure die cast aluminium with heat dissipation housing with toughened glass cover and secondary lens on each LED & should be SMD type. The System Luminaire efficacy >= 120 lm/watt with High power LEDs is to be used and potted driver must be potted & has a unique BISR number with input voltage AC 140 V to 270 V AC with High voltage Cut off @ >= 300 V AC and auto resetting safety Input Frequency 50 Hz ± 3 % , Power factor > 0.95 driver Efficiency > 85 %, THD (I) < 10 %, humidity 10 % to 90 % RH, CRI >70, Working Temp -10 C to 50 C. The Luminaire shall be BIS certified and T.C certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70 % lumen maintaned and CCT 5700 K+335K. Surge protection shall be min>= 4 KV internal and min 10 KV external.Note-: The manufacture should provide warranty of street light for 2 years. Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.