Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | TOILET BLOCK. Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out construction of shoring & bracing ,removal of stumps and other deleterious materials and disposal upto a lead of 50m,dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 3 | Sand filling in plinth including supply of necessary quantity of sand from a distance not excluding 8km from the site of work and including watering dressing etc. rate to include cost of all materials, labour and T&P etc.required for proper completion of the work. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 5 | Preconstruction Antitermite treatment of soil under floors using chemical emulsion |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR PLINTH BEAM] M-20. |
| 7 | As in item no. 6 above but for Lintle beam (Using M20 Mix concrete). |
| 8 | As in item no. 6 above but for Slab (Using M20 Mix concrete). |
| 9 | As in item no. 6 above but for Beams (Using M20 Mix concrete). |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | Providing and laying cement-based integral waterproofing treatment on roofs/terraces including surface preparation, application of cement slurry with waterproofing compound, laying brick bats in cement mortar (1:5) to required slope, second slurry coat, and finishing with 20 mm thick jointless cement mortar (1:4) with glass fibre cloth, neat cement finish and 300×300 mm grooves, complete with curing and water ponding test for two weeks, average thickness 120 mm (minimum 65 mm at khurra), as directed |
| 14 | Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws. Single leaf |
| 15 | both side laminated |
| 16 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 17 | P/F Mild steel TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 18 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 19 | 12mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand |
| 20 | 15mm thick plaster wit cement mortar in proportion of 1:6 cement & Coarse sand) |
| 21 | 40 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 22 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 24 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (Inner Surface). |
| 26 | Finishing walls with Putty approved brand and manufacture and of required shade and undecorated wall surface to give even sahde over including curing and cost of all material, labour T & P etc required for proper completion of the work. |
| 27 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 28 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating notless than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 29 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250mm X 10 mm |
| 30 | Providing and fixing aluminium anodised handles with screws etc. complete 125 mm |
| 31 | 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 33 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 35 | P/F of S.S. Railing (Grade -304) |
| 36 | centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 37 | Suspended floors, roofs, landings, balconies and access platform |
| 38 | PLUMBING WORK. Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 39 | Providing and fixing white viterous china pedestal type water closet (europen type) with seat and lid, 10 litre low level flusing cistem with fittings &C.I/M.S Brakets ,40mm fluse bend , overflow arrangment with special of standard make and mosqiito proof coupling of approved muncipal design complete including painting of fitting and brackets , cutting and making good the walls and floors where ever required .Confirming to IS : 7231, Parryware, /Hindware/ Seabird/Orient(Coral) W.C. pan with ISI marked white solid plastic seat |
| 40 | Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1 mtr long with S.S. tringular plate to Eureopean type W.C. of quality and make as approved by engineer - in- charge |
| 41 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. (a)White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 42 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : one urinal basins with white P.V.C. automatic flushing cistern |
| 43 | Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth Granite stone of approved shade |
| 44 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 45 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 46 | 40 mm dia |
| 47 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 48 | Providing and fixing C.P. brass bib cock of Hindware Make Model Contessa Neo (F730041) a) 15 mm nominal bore |
| 49 | Providing and fixing C.P. brass angle valve of Hindware Make Model Contessa Neo (F730039) (a) 15 mm nominal bore |
| 50 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 51 | Providing and fixing plain bend of required degree. |
| 52 | Providing and fixing PTMT grating of approved quality. 100 mm nominal dia |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes |
| 54 | 25mm dia nominal outer dia pipes |
| 55 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal bore |
| 56 | 25mm dia nominal bore |
| 57 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore |
| 58 | Providing and fixing of Sand cast iron pipe (Soil, waste & vent pipe) (a) 100 mm dia |
| 59 | b) 75mm dia |
| 60 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes ) 110 mm dia |
| 61 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 62 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 63 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 64 | Providing, laying and jointing UPVC Pipe Astral Make 6Kg/Cm2 cat. including testing of joints etc. complete. 100 mm diameter |
| 65 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100mm dia SW pipe |
| 66 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 150 (i) For Sewer Line |
| 67 | SEPTIC TANK. Excavation in foundation in ordinary soil ( Loam, clay or sand ) including lift up to 1.5 M lead up to 30 m and including filling watering and ramming of excavated eath in to the trenches or in to the space between the building and the side of foundation trenches. |
| 68 | Providing and laying of cement concrete in footing and base for columns. Encluding the cost of centring and shuttering. 1:4:8 (1cement :4 coarse sand :8 grade stone aggregate 40mm nominal size) |
| 69 | 1st Class brick work in 1:6 cement & coarse sand of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work. |
| 70 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20 |
| 71 | Mild steel T M T Fe 500 or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shaoe as necessary including bending for proper completion of the work and including supply of steel. Its wastage bend, hookes and authorised averlapping shall be measured upto floor two level. |
| 72 | 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 73 | 40mm thick Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal sizelaid in onelayer neat cement. |
| 74 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design |
| 75 | ELECTRIC WORK. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 76 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 77 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 78 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 12 Module (200mmX150mm) |
| 79 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 80 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 300 mm sweep |
| 81 | Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12way, Double door |
| 82 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 83 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 84 | Supply and fixing of 40 Amp. DP MCB (10 KA) C Curve. CAT A |
| 85 | Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . |
| 86 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 16 sq mm x 2core |
| 87 | Supply of A.C. 230/250 VOLTS, 50HZ exhaust fan including providing nuts, bolt, mounting fram and other accessories including connections including connections etc. complete as required. 300 mm Sweep |
| 88 | MULTIPURPOSE HALL. Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out construction of shoring & bracing ,removal of stumps and other deleterious materials and disposal upto a lead of 50m,dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 89 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 90 | Sand filling in plinth including supply of necessary quantity of sand from a distance not excluding 8km from the site of work and including watering dressing etc. rate to include cost of all materials, labour and T&P etc.required for proper completion of the work. |
| 91 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 92 | Preconstruction Antitermite treatment of soil under floors using chemical emulsion |
| 93 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [FOR FOUNDATION] M-20. |
| 94 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR PLINTH BEAM] M-20. |
| 95 | As in item no. 6 above but for Column (Using M20 Mix concrete). (UP TO PLINTH LAVEL) |
| 96 | As in item no. 6 above but for Column (Using M20 Mix concrete). (ABOVE PLINTH LAVEL) |
| 97 | As in item no. 6 above but for Lintels (Using M20 Mix concrete). |
| 98 | As in item no. 6 above but for Slab (Using M20 Mix concrete). |
| 99 | As in item no. 6 above but for Beams (Using M20 Mix concrete). |
| 100 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 101 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 102 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 103 | Providing and laying cement-based integral waterproofing treatment on roofs/terraces including surface preparation, application of cement slurry with waterproofing compound, laying brick bats in cement mortar (1:5) to required slope, second slurry coat, and finishing with 20 mm thick jointless cement mortar (1:4) with glass fibre cloth, neat cement finish and 300×300 mm grooves, complete with curing and water ponding test for two weeks, average thickness 120 mm (minimum 65 mm at khurra), as directed |
| 104 | P/F Mild steel TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 105 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 106 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 107 | Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.(With MICA ) Single leaf |
| 108 | Double leaf |
| 109 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 110 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 111 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 112 | 12mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand |
| 113 | 15mm thick plaster wit cement mortar in proportion of 1:6 cement & Coarse sand) |
| 114 | 40 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 115 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size of Tile 600 x 600 mm |
| 116 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 117 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 118 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 119 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 120 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 121 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 122 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specificationsPainting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 123 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 124 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (Inner Surface). |
| 125 | Finishing walls with Putty approved brand and manufacture and of required shade and undecorated wall surface to give even sahde over including curing and cost of all material, labour T & P etc required for proper completion of the work. |
| 126 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 127 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete, Gutter (600 mm over all girth) |
| 128 | Steek work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washer etc. complete (Hot finishes welded type tubes.) |
| 129 | INTERLOCKING TILES WORK. Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. |
| 130 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. |
| 131 | P/L GSB layer under interlocking tiles DSR-16.78.2 |
| 132 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 133 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 134 | PLUMBING WORK. Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 135 | Providing and fixing white viterous china pedestal type water closet (europen type) with seat and lid, 10 litre low level flusing cistem with fittings &C.I/M.S Brakets ,40mm fluse bend , overflow arrangment with special of standard make and mosqiito proof coupling of approved muncipal design complete including painting of fitting and brackets , cutting and making good the walls and floors where ever required.Confirming to IS:7231, Parryware,/Hindware/Seabird/Orient(Coral) W.C. pan with ISI marked white solid plastic seat |
| 136 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 137 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia |
| 138 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length. 15 mm nominal bore |
| 139 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 140 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 141 | P/Placing on terrace (at all floor levels) PVC water storage tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and base supports for tank complete as per direction of Engineer-in-charge. |
| 142 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes |
| 143 | 25mm dia nominal outer dia pipes |
| 144 | Providing and fixing CPVC pipes complete with CPVC fittings and clamps, including cutting and making good walls etc. (internal work). 20mm dia nominal bore |
| 145 | 25mm dia nominal bore |
| 146 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore |
| 147 | Providing and fixing on wall face unplasticised-Rigid PVC pipes. (a) 100 mm dia P.V.C. pipe |
| 148 | b) 90 mm dia P.V.C. pipe |
| 149 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 90 mm |
| 150 | Size 110 mm |
| 151 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp |
| 152 | Supply and fixing trap of self cleansing design with scrwed down or hinged grating with or without vent arm complete |
| 153 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 154 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 155 | Providing, laying and jointing PVC pipes including testing of joints etc. complete.100mm diameter |
| 156 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100mm dia SW pipe |
| 157 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type |
| 158 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 159 | SEPTIC TANK. Excavation in foundation in ordinary soil ( Loam, clay or sand ) including lift up to 1.5 M lead up to 30 m and including filling watering and ramming of excavated eath in to the trenches or in to the space between the building and the side of foundation trenches. |
| 160 | Providing and laying of cement concrete in footing and base for columns. Encluding the cost of centring and shuttering. 1:4:8 (1cement :4 coarse sand :8 grade stone aggregate 40mm nominal size) |
| 161 | 1st Class brick work in 1:6 cement & coarse sand of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work. |
| 162 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20 |
| 163 | Mild steel T M T Fe 500 or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shaoe as necessary including bending for proper completion of the work and including supply of steel. Its wastage bend, hookes and authorised averlapping shall be measured upto floor two level. |
| 164 | 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 165 | 40mm thick Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal sizelaid in onelayer neat cement. |
| 166 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design |
| 167 | ELECTRIC WORK. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 168 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 169 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 170 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 171 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm dia PVC conduit |
| 172 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) |
| 173 | 12 Module (200mmX150mm) |
| 174 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated shidet cover on the fan box etc. as required |
| 175 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 176 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 177 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 178 | S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect. CAT-AAA |
| 179 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) |
| 180 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 181 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 40 amp. |
| 182 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 183 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 184 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 185 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 186 | Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep |
| 187 | Supplying of totally enclosed exhaust fan, 300 mm sweep continously rated highly efficient heavy - duty motor similar to havelles , crompton cat. Trans air 12\\" or equivalent. 300 mm sweep. |
| 188 | Supply and laying of aluminium conductor PVC. insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make- Havels / Pasaka. 16 sqmm 4 core |
| 189 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete with all respects. The instrument chamber shall be separate and shall comprise of plug type ammetre, voltmetre, selector switches for ammetre and voltmetre instrument, fuses current transformer etc. the board shall have suitable capacity electrolytic Aluminium busbars as per IS : 8623 insulated with heat shrink sleevings and mounted on non hygroscopic supports such as CMC/DMC supports with detachable side cover and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entry boxes in case of pedestal type, cable sockets compression glands and indicating lamp for incoming etc.The job include the grounting of the board as per direction of Engineer in charge. All outgoing switches of 100 Amp and above will be provided with Amp Metre, current transformers and selector switches etc. and instrument fuses. The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm /2mm cubicle type switch board shall be of cat. A. B. & B -II and pdestal type for cat. C only (a) Incoming : 100 Amp. TPN -1 No. Outgoing :32 Amp. TPN -3 Nos. |
| 190 | Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work |
| 191 | Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. |
| 192 | LIBRARY. Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 193 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 194 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. |
| 195 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 196 | Providing and injecting chemical emulsion for pre-construction anti-termite treatment to create a continuous barrier under and around foundations, column pits, wall trenches, plinth filling, floor-wall junctions, external perimeter, expansion joints, and around pipes/conduits, complete as per IS 6313 (Part II). Using approved chemicals (Aldrin/Heptachlor/Chlordane or equivalent) with application rates: 5 L/sqm for masonry & foundation, 7.5 L/sqm for backfill and external perimeter, 5 L/sqm for plinth top and under apron, measured on plinth area at ground floor level. |
| 197 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [Foundation] |
| 198 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR PLINTH BEAM] |
| 199 | As above but for Lintel Bend using (1:1.5:3) mix concrete |
| 200 | As above but for Slab using (1:1.5:3) mix concrete |
| 201 | As above but for Beam using (1:1.5:3) mix concrete |
| 202 | As UP to but for Column using (1:1.5:3) mix concrete |
| 203 | As above but for Column using (1:1.5:3) mix concrete |
| 204 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 205 | Painting on D.P.C with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 Kg/Sq.M. approx including cost of fuel if any. |
| 206 | Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 207 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 208 | Providing and laying cement-based integral waterproofing treatment on roofs/terraces including surface preparation, application of cement slurry with waterproofing compound, laying brick bats in cement mortar (1:5) to required slope, second slurry coat, and finishing with 20 mm thick jointless cement mortar (1:4) with glass fibre cloth, neat cement finish and 300×300 mm grooves, complete with curing and water ponding test for two weeks, average thickness 120 mm (minimum 65 mm at khurra), as directed |
| 209 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (Double Leaf) |
| 210 | both side laminated |
| 211 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 212 | P/F Mild steel TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 213 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 214 | 12mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand |
| 215 | 15mm thick plaster wit cement mortar in proportion of 1:6 cement & Coarse sand) |
| 216 | 40 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 217 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 218 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 219 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 220 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 221 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (Inner Surface). |
| 222 | Finishing walls with Putty approved brand and manufacture and of required shade and undecorated wall surface to give even sahde over including curing and cost of all material, labour T & P etc required for proper completion of the work. |
| 223 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 224 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 225 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm |
| 226 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250mm X 10 mm |
| 227 | Providing and fixing aluminium anodised handles with screws etc. complete 125 mm |
| 228 | 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. |
| 229 | Supply & fixing of black board(Green Magnetic Resin 2400x1200 mm size) |
| 230 | centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete |
| 231 | lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 232 | Suspended floors, roofs, landings, balconies and access platform |
| 233 | columns, pillars, piers, Abutments, posts and Struts |
| 234 | INTERLOCKING TILES WORK. Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. |
| 235 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. |
| 236 | P/L GSB layer under interlocking tiles |
| 237 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 238 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 239 | PLUMBING WORK. Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes ) 110 mm dia |
| 240 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm dia |
| 241 | Shoe (Plain)110 mm dia |
| 242 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 243 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 244 | ELECTRIC WORK. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 245 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 246 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 247 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 248 | Supply fixing and concealing of 25 mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . ( for Telephone/Television points) |
| 249 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 250 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 251 | Supply fixing of electronic fan regulator(modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 252 | Supply anf fixing of recess / Surface /Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder Coated die cast aluminium housing with heat sink diffuser / Reflector and driver set complete in all respect. CAT -AA |
| 253 | S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect. CAT-AAA |
| 254 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) |
| 255 | Supply and fixing of 240 volts 'L' series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. (CAT: B) |
| 256 | Supply fixing of 63 Amp. 2 pole mcb(10KA). (CAT: B) |
| 257 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 258 | Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. |
| 259 | Supply and installation of a 600×600×6 mm G.I. plate earth electrode buried vertically at a depth of at least 3 m below ground, complete with 20 mm G.I. watering pipe and funnel, two No. 8–10 SWG G.I. earth leads in 15 mm G.I. pipe up to switchboard (pipe and wire from apron to switchboard extra), including 30 cm C.I. frame with hinged cover, masonry chamber, and 150 mm layers of charcoal/coke and salt all around, complete. |
| 260 | Supply and laying of 25mm x 5 mm G.I. strip from earth electrode directly in the ground as required complete in all respects. |
| 261 | Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep |
| 262 | Supply and laying of aluminium conductor PVC. insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make- Havels / Pasaka 16 sqmm 2 core |
| 263 | Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work |
| 264 | Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail