Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | DRINKING WATER POST. Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 2 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). UP TO P.L in Plinth Beam |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (Above plinth Beam). R.C.C. work in Slab |
| 6 | R.C.C. work in Beam |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 10 | Providing and laying cement-based integral waterproofing treatment on roofs/terraces including surface preparation, application of cement slurry with waterproofing compound, laying brick bats in cement mortar (1:5) to required slope, second slurry coat, and finishing with 20 mm thick jointless cement mortar (1:4) with glass fibre cloth, neat cement finish and 300×300 mm grooves, complete with curing and water ponding test for two weeks, average thickness 120 mm (minimum 65 mm at khurra), as directed |
| 11 | P/F Mild steel TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 12 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 13 | 40 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 14 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.11.56.1 Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 15 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of step sand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 16 | Finishing walls with Putty approved brand and manufacture and of required shade and undecorated wall surface to give even sahde over including curing and cost of all material, labour T & P etc required for proper completion of the work. |
| 17 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.43 lacsLtr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 18 | centering and shuttering including strutting, propping etc. and removal of form forlintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Suspended floors, roofs, landings, balconies and access platform |
| 20 | PLUMBING WORK. Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 21 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.110mm diameter |
| 22 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 23 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall. 20mm dia nominal bore |
| 25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 26 | 25 mm dia nominal outer dia pipes |
| 27 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.15mm nominal bore |
| 28 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore |
| 29 | Providing and fixing of RO With water cooler 150 ltr/hours (usha/ Birla / Blue star etc SRA 150150 G S S 304) |
| 30 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to 15mm nominal bore |
| 31 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore |
| 32 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 33 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300mm dia |
| 34 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (I) 150 mm nominal size dia |
| 35 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (I) 150 mm nominal size dia. |
| 36 | Supplying, filling, spreading & leveling p gravel of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 37 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 38 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of : 150 mm dia |
| 39 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp. |
| 40 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia. |
| 41 | PUMPING SET KSB, V-GUARD, CROMPTON make submersible pump set suitable for installation in bore well of min 150 mm inner dia preferably more and having under noted With Electrical control panel, supporting wire, clips etc specifications.[2.0 H.P.} |
| 42 | Supply and fixing of finolex of copper cable ISI marked submersible cable of size 3 core 2.5 sq mm |
| 43 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore |
| 44 | ELECTRIC WORK . Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 45 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 46 | Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 47 | Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects. |
| 48 | Supply fixing and concealing of 20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . ( for Telephone/Television points) |
| 49 | S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect. CAT-AAA |
| 50 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way Double door |
| 51 | Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) |
| 52 | Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A) 40 AMP. DP MCB. |
| 53 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75X75 )mm |
| 54 | Supply and laying of aluminium conductor PVC. insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make- Havels / Pasaka. 16 sqmm 4 core |
| 55 | M.P. HALL. Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out construction of shoring & bracing ,removal of stumps and other deleterious materials and disposal upto a lead of 50m,dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 56 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 57 | Sand filling in plinth including supply of necessary quantity of sand from a distance not excluding 8km from the site of work and including watering dressing etc. rate to include cost of all materials, labour and T&P etc.required for proper completion of the work. |
| 58 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 59 | Preconstruction Antitermite treatment of soil under floors using chemical emulsion |
| 60 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stoneaggregate 20 mm nominal size derived from natural sources) [FOR FOUNDATION] |
| 61 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR PLINTH BEAM] |
| 62 | As in item no. 6 above but for Column (Using M20 Mix concrete). (UP TO PLINTH LAVEL) |
| 63 | As in item no. 6 above but for Column (Using M20 Mix concrete). (ABOVE PLINTH LAVEL) |
| 64 | As in item no. 6 above but for Lintels (Using M20 Mix concrete). |
| 65 | As in item no. 6 above but for Slab (Using M20 Mix concrete). |
| 66 | As in item no. 6 above but for Beams (Using M20 Mix concrete). |
| 67 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 68 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 69 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 coarse sand) |
| 70 | Providing and laying cement-based integral waterproofing treatment on roofs/terraces including surface preparation, application of cement slurry with waterproofing compound, laying brick bats in cement mortar (1:5) to required slope, second slurry coat, and finishing with 20 mm thick jointless cement mortar (1:4) with glass fibre cloth, neat cement finish and 300×300 mm grooves, complete with curing and water ponding test for two weeks, average thickness 120 mm (minimum 65 mm at khurra), as directed |
| 71 | P/F Mild steel TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 72 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 73 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 74 | Providing & fixing ISI marked flush door shutters conforming IS: 2202 non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws.(With MICA ) Single leaf |
| 75 | Double leaf |
| 76 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 77 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 78 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 79 | 12mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand |
| 80 | 15mm thick plaster wit cement mortar in proportion of 1:6 cement & Coarse sand) |
| 81 | 40 mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 82 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size of Tile 600 x 600 mm |
| 83 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 84 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 85 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 86 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 87 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 88 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 89 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specificationsPainting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 90 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 91 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (Inner Surface). |
| 92 | Finishing walls with Putty approved brand and manufacture and of required shade and undecorated wall surface to give even sahde over including curing and cost of all material, labour T & P etc required for proper completion of the work. |
| 93 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 94 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete, Gutter (600 mm over all girth) |
| 95 | Steek work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washer etc. complete (Hot finishes welded type tubes.) |
| 96 | INTERLOCKING TILES WORK. Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. |
| 97 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. |
| 98 | P/L GSB layer under interlocking tiles DSR-16.78.2 |
| 99 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 100 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 101 | PLUMBING WORK. Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 102 | Providing and fixing white viterous china pedestal type water closet (europen type) with seat and lid, 10 litre low level flusing cistem with fittings &C.I/M.S Brakets ,40mm fluse bend , overflow arrangment with special of standard make and mosqiito proof coupling of approved muncipal design complete including painting of fitting and brackets , cutting and making good the walls and floors where ever required.Confirming to IS:7231, Parryware,/Hindware/Seabird/Orient(Coral) W.C. pan with ISI marked white solid plastic seat |
| 103 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 104 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia |
| 105 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length. 15 mm nominal bore |
| 106 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 107 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 108 | P/Placing on terrace (at all floor levels) PVC water storage tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and base supports for tank complete as per direction of Engineer-in-charge. |
| 109 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes |
| 110 | 25mm dia nominal outer dia pipes |
| 111 | Providing and fixing CPVC pipes complete with CPVC fittings and clamps, including cutting and making good walls etc. (internal work). 20mm dia nominal bore |
| 112 | 25mm dia nominal bore |
| 113 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore |
| 114 | Providing and fixing on wall face unplasticised-Rigid PVC pipes. (a) 100 mm dia P.V.C. pipe |
| 115 | b) 90 mm dia P.V.C. pipe |
| 116 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. Size 90 mm |
| 117 | Size 110 mm |
| 118 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp |
| 119 | Supply and fixing trap of self cleansing design with scrwed down or hinged grating with or without vent arm complete |
| 120 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 121 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 122 | Providing, laying and jointing PVC pipes including testing of joints etc. complete.100mm diameter |
| 123 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design 100mm dia SW pipe |
| 124 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type |
| 125 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 126 | SEPTIC TANK. Excavation in foundation in ordinary soil ( Loam, clay or sand ) including lift up to 1.5 M lead up to 30 m and including filling watering and ramming of excavated eath in to the trenches or in to the space between the building and the side of foundation trenches. |
| 127 | Providing and laying of cement concrete in footing and base for columns. Encluding the cost of centring and shuttering. 1:4:8 (1cement :4 coarse sand :8 grade stone aggregate 40mm nominal size) |
| 128 | 1st Class brick work in 1:6 cement & coarse sand of 1.50 fineness modulus mortar in foundation & plinth including supply of all material labour and tools and plants etc required for proper completion of work. |
| 129 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion of 1:1.5:3(M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B WG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20 |
| 130 | Mild steel T M T Fe 500 or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shaoe as necessary including bending for proper completion of the work and including supply of steel. Its wastage bend, hookes and authorised averlapping shall be measured upto floor two level. |
| 131 | 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 132 | 40mm thick Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal sizelaid in onelayer neat cement. |
| 133 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design |
| 134 | ELECTRIC WORK. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 135 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 136 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 137 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 138 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm dia PVC conduit |
| 139 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) |
| 140 | 12 Module (200mmX150mm) |
| 141 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated shidet cover on the fan box etc. as required |
| 142 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 143 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 144 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 145 | S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect. CAT-AAA |
| 146 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way Double door (4 + 12) |
| 147 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 148 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 40 amp. |
| 149 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 150 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 151 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 152 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 153 | Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep |
| 154 | Supplying of totally enclosed exhaust fan, 300 mm sweep continously rated highly efficient heavy - duty motor similar to havelles , crompton cat. Trans air 12\\" or equivalent. 300 mm sweep. |
| 155 | Supply and laying of aluminium conductor PVC. insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make- Havels / Pasaka. 16 sqmm 4 core |
| 156 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete with all respects. The instrument chamber shall be separate and shall comprise of plug type ammetre, voltmetre, selector switches for ammetre and voltmetre instrument, fuses current transformer etc. the board shall have suitable capacity electrolytic Aluminium busbars as per IS : 8623 insulated with heat shrink sleevings and mounted on non hygroscopic supports such as CMC/DMC supports with detachable side cover and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entry boxes in case of pedestal type, cable sockets compression glands and indicating lamp for incoming etc.The job include the grounting of the board as per direction of Engineer in charge. All outgoing switches of 100 Amp and above will be provided with Amp Metre, current transformers and selector switches etc. and instrument fuses. The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm /2mm cubicle type switch board shall be of cat. A. B. & B -II and pdestal type for cat. C only (a) Incoming : 100 Amp. TPN -1 No. Outgoing :32 Amp. TPN -3 Nos. |
| 157 | Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work |
| 158 | Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail