| 1 | M&L 300 mm dia bore holes in normal available starta upto 50 m depth complete all as specified and directed. |
| 2 | S&F PVC pipe 150 mm dia class 'A' including all necessary fittings complete all as specified and directed. |
| 3 | M&L gravel packing as in filter media of size 12.5 mm size around PVC pipe in pit complete all as specified and directed. |
| 4 | M&L gravel packing as in filter media of size 3 mm to 5 mm size around PVC pipe in pit complete all as specified and directed. |
| 5 | M&L coarse sand filling around PVC pipe in pit complete all as specified and directed. |
| 6 | Exacavating over areas not exceeding 1.50 mtr deep and getting out in soft/loose soil complete all as specified and directed. |
| 7 | Exacavating over areas exceeding 1.50 m but not exceeding 3.00 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Exacavating over areas exceeding 3.00 m but not exceeding 4.50 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 9 | M&L PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundation and mass conrete complete all as specified and directed. |
| 10 | M&L formwork to rough finished flat surfaces of concrete foundations, footings , bases of coulmns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams ; and other similar works; vertica or to batter complete all as specified and directed. |
| 11 | M&L cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in foundation, including rafts, footings , foundation beams, plinth beams, bases for coulmns etc and all other similar works complete all as specified and directed. |
| 12 | Use and waste of formwork to fair finished flat surfaces faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. |
| 13 | M&L cement concrete design mix M-25 (using 20 mm graded stone aggregate) for walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses and all other similar works complete all as specified and directed. |
| 14 | Use and waste of formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat complete all as specified and directed. |
| 15 | M&L cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in beams, cantileveres, bressummers, lintels over 1.50 mtr span and all other similar works complete all as specified and directed. |
| 16 | M&L TMT bars10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and direceted. |
| 17 | M&L TMT bars 6 to 8mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed. |
| 18 | All as per Srl Item No-17 here-in-before but 5mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified & directed. |
| 19 | M&L Rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface complete all as specified and directed. |
| 20 | Returning, filling in,including spreading,levelling,watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. |
| 21 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 22 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 23 | M&L preperation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not other described and applying two coats of synthetic enamel paint (ordinary tint) (each coat) over a coat of primer red oxide (zinc chrome) complete all as specified and directed. |
| 24 | Excavating in trenchs not exceeding 1.5m wide andnot exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits , manholes, pier holes , etc.not exceeding 10 Sq m on plan and not exceeding 1.5m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 25 | M&L brick work with sub class \\"B\\" bricks straight or curved on plan to any radius in half brick thick) built in cement mortar 1:6 complete all as specified and directed. |
| 26 | M&L brick work, sub class B, laid on edge in floors; old size bricks built in cement mortar 1:6 complete all as specified and directed. |
| 27 | M&L cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains finished even and fair complete all as specified and directed. |
| 28 | Earth work in excavation for all kind of soil by mechanical means (Hydraulic excavator) in foundation trenches or drain (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out excavated soil and disposal of surplus excaveted soil as directed, within a lead of 50m complete all as specified and directed. |
| 29 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and exceeding 1.5 metre but not exceeding 3 metre depth and not exc 10 Sqm on plan, for shafts, wells, cesspits, manholes, pier holes, etc and getting out, complete all as specified and directed. |
| 30 | M&L concrete bed to drain pipes in PCC 1:3:6, type C2 (using 40 mm graded aggregate) for 200 mm bore pipe including forming crades complete all as specified and directed. |
| 31 | M&L concrete bed to drain pipes in PCC 1:3:6, type C2 (using 40 mm graded aggregate) for 150 mm bore pipe including forming crades complete all as specified and directed. |
| 32 | M&L 200 mm dia reinforced concrete pipes, class NP2 laid and jointed complete with collars in trenches complete all as specified and directed. |
| 33 | M&L 150 mm dia reinforced concrete pipes,class NP2 laid and jointed complete with collars in trenches complete all as specified and directed. |
| 34 | M&L cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for & forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished and reforming branching as required for 200 mm dia pipes complete all as specified and directed. |
| 35 | M&L Rendering/plastering, 15mm thick in cement mortar 1:4 on any face of brick walls or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 36 | M&L brick work in cement mortar 1:4 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius complete all as specified and directed. |
| 37 | M&L brick work using sub-class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 ccomplete all as specified and directed. |
| 38 | M&L RCC 1:2:4, type B1 (using 20mm graded strone aggregate) as in Precast cover slab , shelves and similar articles and setting in mortar complete with joints to match complete all as specified and directed. |
| 39 | Demolition of PCC of any description and in any position as in not otherwise specifically provided for complete all as specified and directed. |
| 40 | M&L 100 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base flooring complete all as directed. |
| 41 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.Makes: SITCO, POOJA CONCRETE, MOHINDRA INDUSTRIES, KB SPUN, SARAL IMPEX, RANA TILES CO, SHINO TILES, RN TILES & PAVERS, SWASTIK ALW |
| 42 | M&L cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed. |
| 43 | Demolition of brick work built in cement mortar of any specification and in any position complete all as specified and directed. |
| 44 | Demolition of reinforced cement concrete of any description complete all as specified and directed. |
| 45 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area complete all as specified. |
| 46 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc in hard/dense soil all as specified. |
| 47 | M&L RCC M-25 Design Mix (using 20 mm graded stone aggregate) for Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 48 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for Square, Circular rectangular on plan or polygonal flat rough finished surfaces of concrete complete all as specified and directed. |
| 49 | Formwork to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 50 | M&L RCC Design mix M-25 (using 20 mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. |
| 51 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but not exceeding 20cm Wide complete all as specified and directed. |
| 52 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 53 | M&L RCC Design mix M-25 (using 20 mm graded stone aggregate) in beams in chajjas complete all as specified and directed. |
| 54 | Formwork to chullah hoods, chajjas, troughs and similar items in cluding edges complete all as specified and directed. |
| 55 | M&L Rendering 15 mm thick in cement mortar 1: 6 on fair faces of brick masonary surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 56 | M&L 5mm thick cement mortar 1: 4 as ceiling surfaces plastering and finished even & smooth complete all as specified and directed. |
| 57 | Supply only integral water proofing compound ccomplete all as specified and directed. |
| 58 | M&L two coats of cement based paint on external wall surfaces over a coat of alkali resistent primer incl preparation newly plastered surface complete all as specified and directed. |
| 59 | M&L two coats of oil bound distemper on internal wall surfaces over a coat of primer including preparation newly plastered surface and 1mm thick wall are putty complete all as specified and directed. |
| 60 | M&L two coats of oil bound distemper on ceiling including preparation newly plastered surface and chalk whiting complete all as specified. |
| 61 | M&L Moorum/red bajri filling in floors or paving, laid in layers not exceeding 15 cm thick, spread, leveled and rammed including watering complete all as specified and directed. |
| 62 | M&L hard core filling under floor, breaking stone or boulder exceeding 63mm and not exceeding 100mm gauge of sand stone complete all as specified and directed. |
| 63 | M&L Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 64 | M&L glazed ceramic coloured tiles of size 450 mm x 350 mm and 7mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:4 complete all as specified and directed. Note:- Shade/Colour of tile shall be approved by the GE. |
| 65 | M&L Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and inluding 75mm thick PCC type D2 1:3:6 (using 40 mm graded crushed stone aggregate) and inluding 25mm thick PCC type B1 1:2:4 (using 20 mm graded crushed stone agg) as in sub base of floor complete all as specified and directed. |
| 66 | M&L water proofing treatment to roof surface including parapet wall comprising with the following course of treatment/ specifications form bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. |
| 67 | M&L 75 mm thick cement concrete 1:3:6, type C-2 (using 20mm graded stone aggregate) as in plinth protection, shall be laid in 1:20 slope. The concrete shall be laid at a stretch not exceeding 3-meter in length. Joint gap between the adjoining slab, at corners and at junctions of wall shall not exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen of grade 85/25 garde mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3-meter interval at corner and junction walls complete all as specified and directed. |
| 68 | S&F Providing and fixing factory made uPVC white colour fixed window/ventilators made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose. area not exceeding 1.00 sqm each complete all as specified and directed. |
| 69 | M&L Figured glass 4mm thick pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 70 | M&L Solid PVC door frame single side prelam of size 50mmx47mm made out of 5mm single side prelam pvc sheet reinforced with ms square tube suppling and fixing in opening as per specification & drawing complete all as specified and directed. |
| 71 | S&F Factory made solid panel PVC door shutter 30mm thick (Styles) consisting of frame made out of MS tubes for top and bottom rails. MS frames shall be covered with heat moulded plain coloured PVC,C, channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and both side prelam PVC sheets top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Stiles and rails feathered at edges. Panelling of both side prelam PVC sheet to be fitted in the MS frame with 3 Nos stainless steel hinge 100 mm size, welded/sealed to the stiles rails with suitable PVC sheet beading and jointed together with solvent cement. S&F in the frame as per manufacturer's instructions complete all as specified and directed. |
| 72 | S&F PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified and directed. |
| 73 | S&F PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified and directed. |
| 74 | S&F PTMT door handle, 150 mm long and fixed with steel screws complete all as specified and directed. |
| 75 | S&F in repair Vitreous china squatting pan, Orissa pattern, size 580mmx440mm white/ coloured with integral foot rests including trap set in and including concrete and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed. |
| 76 | S&F in repair Vitreous china wash basin, white/ coloured, flat back, size 550mmx400mm including PTMT waste fittings & pipe, 32mm bore size and angle iron brackets & CP Pillar CP Pillar Brass mixer for mixing hot & cold water screwed down for iron pipe and fixed and making good disturbed surfaces to match with the existing complete all as specified and directed. |
| 77 | S&F in repair 600mmx450mm looking mirror of selected quality mounted on 6mm thick commercial plywood and fixed to wall with plug and screws etc. complete all as specified and directed. |
| 78 | S&F brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 79 | S&F rotational moulded synthetic (HDPE), water storage tank 500 litre capacity (cylinderical vertical with closed top,) hoisted & fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 80 | S&F Chromium plated tubular towel rail 20mm dia D type 60 cm long between flanges complete all as specified and directed. |
| 81 | M&L Concrete bed to drain pipes of 150mm bore in PCC 1:3:6, type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified. |
| 82 | M&L reinforced concrete pipes 150mm dia, NP-3 laid and jointed complete with collars complete all as specified and directed. |
| 83 | M&L Cutting into existing manholes/ crossings of walls etc for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and directed. |
| 84 | M&L Cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains etc complete all as specified and directed. |
| 85 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.as in manhole pipe line portion only complete all as specified and directed. |
| 86 | M&L Providing reinforced cement cocrete 1:2:4, type B-1 (using 20mm graded stone aggregates) as in cover slab (for manhole) and setting in cement mortar 1:4 including necessary form work complete all as specified and directed. |
| 87 | S&F Mild steel galvanized steel tubing 15 mm bore (concealed) with screwed socket joints, medium grade, together with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors including, screwing and waste and for forged bends on piping as required, complete all as specified and directed. |
| 88 | S&F Mild steel galvanized steel tubing 20 mm bore (concealed) with screwed socket joints, medium grade, together with all fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors including, screwing and waste and for forged bends on piping as required, complete all as specified and directed. |
| 89 | S&F Bib taps, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, long shank fancy type screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified and directed. |
| 90 | S&F stop valves/Angle valves, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fix complete all as specified and directed. |
| 91 | S&F Stop valves, cast copper alloy, chromium plated, fancy type, with long shank, (concealed) screwed down, high preesure with crutch or butterfly handle, screwed both ends for iron pipe of bore 20 mm bore of pipe complete all as specified and directed. |
| 92 | S&F Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40gms) complete all as specified and directed. |
| 93 | S&F Soap dish, vitreous China white, approximate chromium plated brass screws complete all as specified and directed. |
| 94 | S&F PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 95 | S&F 110 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joinets, laid in trenches or in floor complete all as specified and directed. |
| 96 | S&F 110 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joinets fixed to walls complete all as specified and directed. |
| 97 | S&F 110 mm dia bore PVC (SWR) bends any radius complete all as specified and directed. |
| 98 | S&F 110 mm dia bore PVC (SWR) bends any radius with oval acess door complete all as specified and directed. |
| 99 | S&F PVC (SWR) 'P' trap 125/110 mm including jointing with solvent cement complete all as specified and directed. |
| 100 | S&F PVC (SWR) gully trap, 125/110 mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 101 | S&F 75 mm dia bore PVC (SWR) pipes single shocketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 102 | S&F 75 mm dia bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 103 | M&L 25 mm granite as in plateform in mortar 1:4 including pointing in white cement complete all as specified and directed. |
| 104 | M&L Point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copper conductor, multi stranded of size 1.5 sqmm, single core, in and including rigid non-metallic PVC conealed conduit, with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and MS pressed steel / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire of size 1.5 sqmm unsheated stranded copper conductor with green PVC insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch. |
| 105 | (b) One socket outlet on the same board controlled by one single pole one way switch |
| 106 | All as per Srl Item No 104 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 Sq mm PVC insulated copper conductor and 2.5 Sqmm copper conductor for continuous earthing complete. |
| 107 | Supply & Fixing Switch piano flush type single pole one way 5/6 Amp complete all as specified and directed. |
| 108 | Supply & Fixing Switch piano flush type 15 amps, single pole one way duly ISI marked complete all as specified and directed. |
| 109 | Supply & Fixing Socket outlet 2 in one , 5/6 Amps flush type ISI marked complete all as specified and directed. |
| 110 | Supply & Fixing Socket outlet, 2 in one 6 pin 5 and 15 Amps piano flush type ISI marked complete all as specified and directed. |
| 111 | Supply & Fixing ceiling rose, PVC/Polycarbonate,isolated three terminals complete all as specified and directed. |
| 112 | Supply & Fixing Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings including 10W LED Bulb complete all as specified and directed. |
| 113 | Supply & Fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all specified and directed. |
| 114 | Supply & Fixing LED tube light fitting 1 X 18 W decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.Makes:- Cat Part No LHEXBLP7UN1W018 of make \\"Havells\\" or techno-commercially equivalent in approved makes. |
| 115 | Supply & Fixing sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 volts 200 Amps rated bus bar, Neutral link,Earth bar and Din rail, 8 way dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified and directed. |
| 116 | Supply & Fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 117 | Supply & Fixing MCB, Single Pole and neutral 240 V, 32 Amps 10 KA 'B' series complete all as specified and directed. |
| 118 | Supply & Fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 119 | Supply, fixing connecting and testing energy efficient (BEE 5 Star rated) electric water heater vertical storage type of 25 Ltrs capacity with Pressure gauge and stainless Steel inner tank, brass assembly, pressure release valve, heating element 1500/2000 W including all other accessories with high quality external finishes single phase with working Voltage 240 volts, 50 Hz complete all as specified and directed. Note: The cost of fixing of geysers including Non return valve/stud/ nuts/fastners, bolts, washers. and making good the disturbed surfaces to match with the existing surface is deemed to be included in the unit rate quoted. |
| 120 | M&L GI Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceiling or laid in floor of 15 mm bore dia with clamps & bolts as required complete all as specified and directed. |
| 121 | Supply & Fixing gun metal, globe or gate valves of size 15 mm with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and directed. |
| 122 | Supply & Fixing PVC connection 15 mm size with brass nuts of length 450 mm for Hot/ Cold water supply complete all as specified and directed. |
| 123 | Supply & fixing for Bib tap cast copper alloy with crutch or butterfly handle,fancy type Chromium plated ,screwed down, screwed for iron pipe or for brass ferrule and fixed of 15 mm dia complete all as specified for connection of hot water supply Please Enable Macros to View BoQ information |
| 124 | Supply & fixing for Bib tap cast copper alloy with crutch or butterfly handle,fancy type Chromium plated ,screwed down, screwed for iron pipe or for brass ferrule and fixed of 15 mm dia complete all as specified for connection of hot water supply Please Enable Macros to View BoQ information |