| 1 | ERRECTION OF 22KV H.T LINE |
| 2 | (i) Digging of pit, (ii) Erection of pole, Laying and concreting of RCC muff (iii) filling of pit & Ramming (iv) Drilling of holes in X-arms (v) fixing of insulator, X-arm, knee-bracing set, top clamp (vi) fixing of Barbed wire, Danger plate (vii) painting of pole S/Pole str. (Complete in all respect). |
| 3 | ERRECTION OF STAY SET |
| 4 | (i) Digging of pit (ii)fixing of stay rod (iii) Filling of pit (iv)Nozzeling & Tighting. |
| 5 | Sagging of ACSR Conductor 6/1/3.35mm (Single wire). |
| 6 | Laying of conductor (i) stringing & sagging (ii) binding with insulator. |
| 7 | MANNUAL CARRIAGE OF H.T LINE MATERIAL CONSIDERING AVERAGE DISTANCE 0.200 K.M. |
| 8 | Erection of 100KVA S/Stn. |
| 9 | Digging of pit for pole and earthing, drilling of holes in x-arm, preparation of plate form, Str. Member C.I A.I. X-arm, knee bracing set, erection of D-pole, c.c.muff, erection of plate form, erection of x-arm, dropout fuse unit, lightning arrester, MCCB switch, L.T box, energy meter, erection of transformer, G.O switch, stay set, jumper earthing 3 sets, L.T cables, painting etc. (Complete in all respect). |
| 10 | Mannual carriage of sub-station material for an average distance of 0.200Km. |
| 11 | Providing Fencing around the Sub-station. |
| 12 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level: 1:4:3 (1 Cement: 4 coarse sand): 5 graded stone aggregate 40 num nominal size) |
| 14 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 11.5.3 (1 cement: 1.5 coarse sand) 3 graded stone aggregate 20 mm nominal size) |
| 15 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 16 | Providing and fixing G1 chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of GI wire of dia 4 mm |
| 17 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 100x35x1.90 mm |
| 18 | Providing and fixing 151 marked oxidised M5. sliding door bolts with nuts and screws etc. complete 250-16 mm |
| 19 | MATERIAL TO BE SUPPLIED BY CONTRACTOR (Subject to the non-availability of material at Divisional Store). |
| 20 | HT line |
| 21 | Prov. RCC Muffs (2000mm) with concrete filling. |
| 22 | Prov. 22kV Pin Insulators with GI Pin (Porcelain,36kV, 10KN) |
| 23 | Prov. stay Wire (7/3.15mm) |
| 24 | Prov. Nuts & bolts. (off soze) |
| 25 | Prov. Aluminium paint. |
| 26 | Prov. Top clamp |
| 27 | Prov. MS Angle Iron (50x50x6mm), Length 2x750 |
| 28 | Prov. support clamp |
| 29 | Prov. Egg Insulator. |
| 30 | Prov. Stay Set HT (i/c stay clamp) |
| 31 | Sub Station |
| 32 | Prov.RCC Muffs (2000mm) with concrete filling. |
| 33 | Prov.GO AB Switch Unit (11KV, 400A, 25KA)Tripple pole O/D Type |
| 34 | Prov.DO Fuse Unit |
| 35 | Prov. Stay Set HT (i/c stay clamp) |
| 36 | Prov.Stay Wire (7/3.15mm) |
| 37 | Prov.LT Distribution Panel Box with MCCB. |
| 38 | Prov.Half Clamp (MS Flat 50x6mm) |
| 39 | Prov.Full Clamps (MS Flat 50x6mm) |
| 40 | Prov.Nuts and Bolts of various sizes (Galvanised / coated) [Preferably 16 mmØ or more (with flat and spring washers)] |
| 41 | Prov.Aluminium Thimble |
| 42 | Prov.Cu Thimble 200Amp. |
| 43 | Prov.Aluminim Paint Please Enable Macros to View BoQ information |