| 1 | Supply and erection standard ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any --Squirrel 6/1/2.11mm dia with calculated aluminium area 20.98 sq.mm,weight 85 kg/ km (50 amps) |
| 2 | Supplying, installation, testing and commissioning of 25 watt 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio * 120 lumens /watt. |
| 3 | Painting of following height steel tubular pole with two coat of aluminium paint of approved brand including cleaning surface as per specification- Around 6 metre |
| 4 | Shifting of solar street light complete set in the same campus as per the shadowfree area as per EIC guidance including all civil works required. |
| 5 | Supply, installation , testing and commissioning of 25 Watt LED street light fitting with inbuilt battery of minimum 12 hour working with auto on-off facility as per sunlight over existing solar street light poles as per specification detailed. |
| 6 | Supplying of Prestressed Concrete poles (PCC) confirming to IS:785 at worksite including required transportation PCC pole 8 m long, 140 Kg (1.01) |
| 7 | Erection of RCC/PCC pole of in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including exacavation and refilling etc as required: above 8 m and upto 11 m |
| 8 | supplying of 4 core 16 mm square armoured pvc/xple 1100V grade cable (Heavy Duty) Al Cable as per IS:1554 (Part 1): 1988 latest |
| 9 | laying of 4core 16mm square armoured pvc/xple 1100V grade cable (Heavy Duty) Al Cable as per IS:1554 (Part 1): 1988 latest to supply power to all 03 nos. of pumps and lighting road crossing with required lux including end termination |
| 10 | Supply and providing insulated line spreader with pvc clamp and nut bolt 440 V Over head line 4wire bare aluminium conductor as instruction by engineer incharge |
| 11 | Supply, installation and connection etc complete at site by Chemical earthing 1 in each block of residential quarters (4 nos. only left), Office main distribution board, Residential main distribution boards, DG sets etc. with copper bonded rod 17mm of 3 m length with sufficient chemical compound as per requirement of site condition |
| 12 | Supply of 4 C x 70 Sq mm armoured xlpe Al power cable (Havy Duty) with required lugs end termination etc |
| 13 | Laying of 4 C x 70 Sq mm armoured xlpe Al power cable (Havy Duty) |
| 14 | Supply & fixing of 415 Volt 200 Amp 4 pole offload Changeover with box for DG & CSPDCL Power switching |
| 15 | Supply & fixing of 4 pole 400 amp Aluminium busbar with box and clamps to fix it |
| 16 | providing and fixing of out door electrc panel box size 600mmx500mmx300 mm powder coated G.I. sheet ( 18 S.W.G) with provision for 4 Nos. four pole isolater |
| 17 | Providing & fixing 400 A, 50 kA, 4P MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc as required |
| 18 | Providing & fixing 25mmx5 mm GI strip on surface or in recess for connections etc as required for earthing |
| 19 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod,anchor plate of size 45cmx45cmX7.m thimble stay clamps ,turn buckels(20mmx60mm),7/4.00mm dia G.I. Stay wire and strain insulatoretc in cement concrete1:3:6(1cement:3 coarse sand:6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required |
| 20 | Supplying of channel iron 75mmx40mmx6mm (7.14 kg per meter) pole top bracket/cross arm for single 11 kV overhead line conductor complete with 50mmx6mm flat iron clamp, bolt, nut and washer including drilling holes for insulatore pins, bolts and nuts etc & painting with primer and finish paint as required |
| 21 | Supply & Erection of pole top/channel iron cross arm angle of 65mm x 65 mm x 6 mm of 5 feet length on steel, tubulat, rail/PCC pole for 5 nos. of conductors with whole , bracket, hardware etc as required |
| 22 | Supplying & erection of cycle insulator with hardware nut bolt clamp for 440 V LT line |
| 23 | Dismantling of Overhead lines comprising of copper/aluminium over head old conductor GI wire cross arms insulators etc as required |
| 24 | Dismantling of pole/street light standard/strut embedded in brick ballast foundation atc as required |
| 25 | Tree Branch cutting at various locations in colony and siding office and whole premices of Kudumkela camp alongside the overhead line |
| 26 | Supply & Erection of GI wire no 8 SWG including binding atc. As required |
| 27 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |