| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR TO FENCING, INTERLOCKING TILES, SECURITY/COMPOUND WALL, GATES, PILLARS AND OTHER CONNECTED ITEMS OF MISC B/R WORKS OF SECTOR I TO XI AT AGE CHARDUAR UNDER GE(N) TEZPUR. Contract No : GE(N)/TEZ/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Dismantling fencing wire mesh any type and size complete all as specified and as directed by Engnr-in-charge. |
| 3 | S&F Pre -PVC coated chain link fencing size of mesh 75 x 75 mm made out of 4mm dia GI wire to any type of standard rails, straining bolts etc complete all as specified and as directed. |
| 4 | S & F Pre -PVC coated chain link fencing size of mesh 100 x 100 mm made out of 4mm dia GI wire to any type of standard rails, straining bolts etc complete all as specified and as directed. |
| 5 | Fixing only chain link mild steel galvanised fencing of any mesh and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. |
| 6 | Supply chain link mild steel galvanised fencing of any size, to any type of standards, rails, straining bolts, weight not exc. 4 kg per sqm etc including provision of binding wire complete all as specified and directed.NOTE : Design of mesh shall be approved by GE. |
| 7 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed.Note: Each line wire to be measured. |
| 8 | M&L Mild steel round bars 10mm dia & over,cut to length, bent to shape required, for strengthening of chain link fencing including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to GD-I. IS-432 (Part I) complete all as specified and directed.Note: Each line wire to be measured. |
| 9 | M&L for MS flat iron (40X6mm) straps for securing corner posts and chain link fencing complete all as specified and directed |
| 10 | S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut not exc 5 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. |
| 11 | M&L for two coat of synthetic enamel paint to steel surface over a coat of red oxide primer, exceeding 10 cm width or girth when unconnected with other painting or when painted in a different tint including preparation of new surfaces or previously untreated steel complete all as specified and as directed. |
| 12 | M&L for two coat of synthetic enamel paint to steel surface over a coat of red oxide primer not exceeding 10 cm width or girth when unconnected with other painting or when painted in a different tint including preparation of new surfaces or previously untreated steel complete all as specified and as directed. |
| 13 | Dismantling / demolition of posts or struts (wood, steel or RCC ) any section, including taking out embedded portion in concrete, brick work, masonry, etc and making good disturbed ground complete all as specified and directed. |
| 14 | Dismantling / demolition of posts or struts (wood, steel or RCC ) any section, including taking out embedded portion in natural ground and making good disturbed ground complete all as specified and directed. |
| 15 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed. |
| 16 | Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells. Cesspits, manholes pier holes etc n.exc 10 sqm on plan and n exc 1.5m in deepth and getting out soft/loose soil. |
| 17 | M&L PCC (1:8:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling, mass concrete, surface channels and drains including demolition of the old unserviceable complete all as specified and directed. |
| 18 | M&L for Brickwork with subclass B brick straight and curvrd on plan to exc 6 m mean radius built in 1:6 cement mortar including demolition of old unserviceable complete all as specified and directed |
| 19 | M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without extra cement complete all as specified and directed. |
| 20 | M&L for preparation of newly plstered surface or concrete surface and applying two coat of white wash complete all as specified and as directed. |
| 21 | Returning , filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm by soft/loose soil complete all as specified and as directed. |
| 22 | Removing excavated material exc. 250m but n.exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 23 | M&L proving PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping, kerbs or mud stops, rounded or chamfered on edges including necessary form work etc. including demolition of the old unserviceable complete all as specifed and directed. |
| 24 | S&F angle iron as in posts and struts in fencing incl cutting top to shape as directed, drilling holes, notching for wire etc and flat iron fillets for securing chain link fencing and similar work conforming to Fe-290 Gde E-165 including dismantling of the same complete all as specifed and directed. |
| 25 | M & L Hardcore of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15mm thick watered and rammed to true surface using broken stone aggregate complete all as specified and directed. |
| 26 | M & L for 75mm thick cement concrete type C2, 1:3:6 (using 40mm graded crushed stone aggregate ) as in foot path/plinth protection and making finished even and smooth without using etra cement including demolition of the old unserviceable complete all as specifed and directed. |
| 27 | M & L for 100mm thick cement concrete type B2, 1:2:4 (using 40mm graded crushed stone aggregate ) as in hard standing and making finished even and smooth without using extra cement including demolition of the old unserviceable complete all as specifed and directed. |
| 28 | S&F in repair PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 29 | M&L for pre-polished and chemically treated anti skid exterior grade coloured chequered tile of size 20cmx20cm and 25mm thick as in path with grey cement and pigments including 15 mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified and directed. Note:- Design/pattern shall be as approved by GE at the time of execution. |
| 30 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed. |
| 31 | M&L cement concrete 1:3:6 type C2 using 40mm graded crushed stone aggregate as in surface channels & Drain including demolition of the old unserviceable complete all as specified and directed. |
| 32 | M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:6 including demolition of the same complete all as specified and directed. |
| 33 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without extra cement complete all as specified and directed. |
| 34 | Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 35 | Ditto all as item No. 38 above but add or deduct for each 25mm girth or part thereof over or under 30 cm complete all as specified and directed. |
| 36 | M&L for Reinforced cement concrete Type B1 1:2:4 (using 20 mm graded crushed stone aggregate), nominal mix, as in Beams, cantilevers, bressummers, lintels over 1.5m span including demolition of the old unserviceable complete all as specified and directed. |
| 37 | M&L for Reinforced cement concrete (nominal mix)Type B1 1:2:4 (using 20 mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts including demolition of the old unserviceable complete all as specified and directed. |
| 38 | M&L for TMT bars , 10 mm dia and over cut to length, bent to shape required including cranking ,bending spirally, hooping for columns, hookings/ends and binding with and including MS wire not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 39 | M&L for Mild steel TMT bars 6 to 8 mm dia as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 40 | Use and waste Formwork to sides of pillars,posts, struts, piers, columns and stanchions in Square, rectangular or polygonal complete all as specified and directed. |
| 41 | Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. in flat surface complete all as specified and directed. |
| 42 | S&F Framed work Fe-410- W(Gde- E-250) quality- B as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including dismantling of old unserviceable complete all as specified and as directed. |
| 43 | Dismantling framed timber scantlings 40 sq. cm & over in section, in any position complete all as specified and as directed. |
| 44 | S&F for mild steel tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 including one shop coat of zinc chromate primer paint ( including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed. |
| 45 | S&F for MS flat iron bent to shape, holes drilled including one coat of red oxide paint complete all as specified and directed. |
| 46 | S&F pre-painted colored trapezoidal profiled Galvalume/ aluminum zinc coating GI based corrugated steel sheet with min 0.50 mm TCT confirmin to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating 550 Mpa yield stress as per AS-1397) as in roof covering/ cladding to wall fixed with self tapping screws colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals) including dismantling of the old unserviceable complete, all as specified and directed. |
| 47 | S&F pre-painted colored plain sheet profiled Galvalume/Zincalume sheet with min 0.50mm TCT confirmin to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating 550 Mpa yield stress as per AS-1397), as in roof covering/ cladding to wall fixed with self tapping screws colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals) including dismantling of the old unserviceable complete, all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |