| 1 | E & M Division Items |
| 2 | Dismantling of old unserviceable/damaged ACSR or AAC conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed. |
| 3 | Dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of PCC and removing unserviceable meterials from site of work complete all as specified and directed. |
| 4 | Dismantling of cross-arms of MS channel or angle of any sections complete all as specified and directed. |
| 5 | Dismantling of insulators of any size/type complete all as specified and directed. |
| 6 | Dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed |
| 7 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 9 | Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed. |
| 10 | Supply and laying burnt bricks of sub-class 'B' of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 11 | Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note: Thickness of sand cushioning after punning down will be measured and paid separately. |
| 12 | M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified |
| 13 | Taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule |
| 14 | Taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule |
| 15 | Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified Note ;- Lugs and Glands will be measured and paid separately. |
| 16 | Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified Note :- Lugs and Glands will be measured and paid separately. |
| 17 | Labour charges for re-laying of serviceable bricks of any size and type recovered during taking out of old cable , over newly laid or re-laid cables all complete as specified and directed. |
| 18 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 3 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 19 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 20 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 21 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 22 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 23 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 24 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 70 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 25 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 95 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 26 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 120 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 27 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 150 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 28 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 185 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 29 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 240 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 30 | M&L GI tube medium grade 80 mm bore for protection of cable including dismantling of old u/s one complete all as specified and directed. |
| 31 | M&L GI tube medium grade 50 mm bore for protection of cable including dismantling of old u/s one complete all as specified and directed. |
| 32 | M&L GI tube medium grade 40 mm bore for protection of cable including dismantling of old u/s one complete all as specified and directed. |
| 33 | Supply and replace including taking down aluminium lugs suitable for 240 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 34 | Supply and replace including taking down aluminium lugs suitable for 185/150 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 35 | Supply and replace including taking down aluminium lugs suitable for 120 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 36 | Supply and replace including taking down aluminium lugs suitable for 95 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 37 | Supply and replace including taking down aluminium lugs suitable for 70 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 38 | Supply and replace including taking down aluminium lugs suitable for 50 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 39 | Supply and replace including taking down aluminium lugs suitable for 35/25 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 40 | Supply and replace including taking down aluminium lugs suitable for 16/10 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 41 | Material and labour for 1.1 KV cable joint kit straight through heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 6 sqmm -16 sqmm 4 core complete all as specified and directed. |
| 42 | Material and labour for 1.1 KV cable joint kit straight through heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 25 sqmm 3.5/4 core- 50 sqmm 3.5/4 core complete all as specified and directed. |
| 43 | Material and labour for 1.1 KV cable joint kit straight through heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes70 sqmm 3.5/4 core- 120 sqmm 3.5/4 core complete all as specified and directed. |
| 44 | Material and labour for 1.1 KV cable joint kit straight through heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes150 sqmm 3.5/4 core- 185sqmm 3.5/4 core complete all as specified and directed. |
| 45 | Material and labour for 1.1 KV cable joint kit straight through heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 240 sqmm 3.5/4 core- 300sqmm 3.5/4 core complete all as specified and directed. |
| 46 | Material and labour for 1.1 KV cable end joint kit heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 6 sqmm -16 sqmm 4 core complete all as specified and directed. |
| 47 | Material and labour for 1.1 KV cable end joint kit heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 25 sqmm -50 sqmm 4/3.5 core complete all as specified and directed. |
| 48 | Material and labour for 1.1 KV cable end joint kit heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 70 sqmm -120 sqmm 4/3.5 core complete all as specified and directed. |
| 49 | Material and labour for 1.1 KV cable end joint kit heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 150sqmm -185 sqmm 4/3.5 core complete all as specified and directed. |
| 50 | Material and labour for 1.1 KV cable end joint kit heat shrinkable type complete with all jointing materials & accessories suitable for cable sizes 240sqmm -300 sqmm 4/3.5 core complete all as specified and directed. |
| 51 | Taking out old existing earthing and M&L for new earthing with galvanised steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level and connected to 32 x 6mm thick GI strip protected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternater layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of soil to a distance not exceeding 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed. |
| 52 | S&F in repairs junction box made from SMC/FRP sheet of size 400x300x190mm having 100A capacity aluminum busbar with 4 way connector fixed to pole /wall with MS clamp made out of FI 25x5mm with nuts, bolts, etc. as required complete all as specified and as directed Please Enable Macros to View BoQ information |