| 1 | M&L for water proofing treatment on existing cleaned on RCC accessible roof with the following specifications and manufacturer's instruction complete all as specified and directed :-(i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966.(ii) Supply and apply of Sikalastic®-590 IN is one component polyurethane based liquid applied membrane with improved water ponding resistance, excellent UV resistance, good crack bridging capacity and great aesthetics. Sikalastic®-590 IN can be applied as a coating or a reinforced liquid applied membrane.(iii) Good behaviour under limited water ponding UV resistant and resistant to yellowing and weathering.(iv) Highly elastic and crack-bridging Non-toxic and VOC compliant water based coating.(v)One component ready to use Excellent adhesion on porous and non-porous substrates.(vi)Seamless waterproofing membrane.(vii) Water vapour permeable for reflective coating to enhance energy efficiency by reducing cooling costs (Sikalastic®-590 IN White).(viii) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & protect the seal with a polysulphide/polyurethane sealant all as per manufacturer's instructions and as directed.(ix) Coverage area:(a)Primer coat Sikalastic®-590 IN diluted with 10 % water = 0.3 kg/Sqm(b)Base coat Sikalastic®-590 IN ~0.5 kg/Sqm(c)Top coat Sikalastic®-590 IN ~0.5 kg/Sqm(d)(Optional) Seal coat Sikalastic®-590 IN 0.3–0.5 kg/SqmNote: The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. |
| 2 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m complete all as specified and directed. |
| 3 | M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 4 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 5 | Supply only integral liquid water proofing compound. |
| 6 | M&L for preparing new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 m/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as ecommended by the manufacturer all as specified and as directed (Note : Rate shall be included for necessary scaffolding and safety measures where required at site ). |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed. |
| 8 | M & L for Vitrified,ultra charged, designed, light shade coloured (light shade), tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 9 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 10 | M & L for Glazed, ceramic, coloured tiles of size 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 11 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings heads, shoes, bends, sawn-necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories). |
| 12 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 13 | All as per description of item No 12 above but except pipe.(Note: Serviceable pipe retrived from item No. 11 shall be re-used.) |
| 14 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 15 | S&F in repairs 110mm bore PVC (SWR) bends of any radius and any type complete all as specified and directed. |
| 16 | S&F in repairs 75mm bore PVC (SWR) bends complete all as specified and directed. |
| 17 | S&F in repairs 110 mm dia vent cowl complete all as specified and directed. |
| 18 | S & F rotational moulded polyethylene water storage tanks of capacity 1000 litres, double layer construction, ISI marked ,(Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one complete all as specified in SSR Part I and as directed. |
| 19 | S&F in repairs 20 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 20 | S&F in repairs gun-metal, globe or gate valves of 20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 21 | S & F in repair fancy type Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete complete all as specified and directed. Make: Jaquar Cat Part No. FUS-29037 or Equivalent make as per list of Makes in PS. |
| 22 | S & F in repair fancy type Two way Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.Make: Jaquar Cat Part No. FUS-29041 or Equivalent make as per list of Makes in PS. |
| 23 | S & F in repair Wall Mixer 3-in-1 System with Provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange complete all as specified and directed. Make: Jaquar Cat Part No. FUS-29281or Equivalent make as per list of Makes in PS. |
| 24 | S & F in repair CP Sink Cock with Provision for Connection to RO from rear side & Swinging Spout complete all as specified and directed. Make: Jaquar Cat Part No. FLR5355N or Equivalent make as per list of Makes in PS. |
| 25 | S & F in repair CP Basin Mixture Single Lever Tall Boy with 150mm Extension Body Fixed Spout without Popup Waste System with 600mm Long Braided Hoses Make: Jaquar Cat Part No. FUS-29005NB or Equivalent make as per list of Makes in PS. |
| 26 | S&F in repair Overhead Shower 180mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1755 or Equivalent make as per list of Makes in PS. |
| 27 | S&F in repair Hand Shower 105mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1709 or Equivalent make as per list of Makes in PS. |
| 28 | S&F in repair of CP fancy type angular stop cock 15mm dia with wall flange complete all as specified & directed.Make: Jaquar Cat Part No.FLR-5053N or Equivalent make as per list of Makes in PS. |
| 29 | S&F in repair for PVC connections 15mm size with PMT nuts of length 600 mm complete all as specified & directed |
| 30 | S & F in repair Single Towel Rail 600mm Long, Stainless Stee complete all as specified & directed Make: Jaquar Cat Part No.ACN 1111SM or Equivalent make as per list of Makes in PS. |
| 31 | S & F in repair Toilet paper Roll Holder with Stainless Steel Flap complete all as specified & directed Make: Jaquar Cat Part No.ACN-1153S or Equivalent make as per list of Makes in PS. |
| 32 | S & F in repair Health Faucet spray with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified & directed Make: Jaquar Cat Part No.ALD-565 or Equivalent make as per list of Makes in PS. |
| 33 | S&F in repair, Sheet Glass Shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long. Complete all as specified and directed. |
| 34 | S&F in repair, 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers. Complete all as specified and directed. |
| 35 | S&F in repair 32 mm dia flexible PVC waste pipe for basin, sink & urinal etc as fixed in repair. |
| 36 | S&F in repair vitreous China wash hand basin with pedestal, white, flat back, size 630 x 450 mm including brackets/rock bolt , including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe. |
| 37 | S&F in repair 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete. |
| 38 | S&F in repair plastic seat cover white for EWC, closed pattern with flat bottom and cover with mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 39 | S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 40 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 41 | S&F 20 mm CPVC pipes SDR 11 & plain SDR 11 including all fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed. |
| 42 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 43 | S&F 25mm CPVC pipes SDR 11 & plain SDR 11 including all fittings on walls & ceiling or laid in floors at height up to 4th storey complete all as specified and directed. |
| 44 | Demolition of concrete of any description below or above ground and in any position not otherwise specifically provided including removing the debries to outside of MD land, where directed.for complete all as directed. |
| 45 | M & L for 75 mm thick PCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub- base floor finished the surface fair and rough to receive subsequent layer with and including necessary formwork complete all as specified and as directed. |
| 46 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 60 mm thick M-35 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |
| 47 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and as directed. |
| 48 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection/flooring etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. Please Enable Macros to View BoQ information |