| 1 | Demolition of stone slabs and tiles of any description or thickness, interlocking tiles in floors/ walls laid bedded and pointed in any mortar complete all as specified and directed. |
| 2 | Excavation over areas not exceeding 1.5 mtrs deep and getting out in any type of soil complete all as specified and directed. |
| 3 | Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil etc complete all as specified and directed. |
| 4 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soil complete all as specified and directed. |
| 5 | M&L broken stone or bounders hardcore of gauge n exc. 63 mm , deposited, spread and levelled in layers n exc. 15 cm thick , watered and rammed to a floor/true surface complete all as specified and directed. |
| 6 | M & L for cement concrete 1:4:8, type D2 using 40mm graded aggregate for in foundations, filling and mass concrete etc complete all as specified and directed. |
| 7 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in requiredcolour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 8 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compactedbed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer throughvibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 9 | Taking down PCC paver block/tiles, dry laid, of any thickness and re-laying in same position or position n exc 500m from location as directed by Engr-in-Charge complete all as specified and directed. |
| 10 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 11 | Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 12 | M&L for brick work in modular size with sub class \\"B\\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 13 | Demolition of reinforced cement concrete (reincorcement cut as required to facilitate demolition) of any description and in any position not otherwise complete all as specified and directed. |
| 14 | M&L RCC 1:1.5:3, Type A 1 Nominal mix (using 20 mm graded aggregate) for slabs supported on walls, beams and column in floors, roofs landings, blaconies , canopies , deck slabs complete all as specified and directed. |
| 15 | Formwork to soffits of suspended slabs such as roof slabs , floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed. |
| 16 | M&L mild steel TMT Bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (annealed not less that 0.90 mm dia or securing with chip) complete all as specified and directed. |
| 17 | All as per Item No.16, above, but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 18 | M & L for cement concrete type B-1, 1:2:4 mix (using 20 mm graded stone aggregate) in benching, bed blocks, coping etc; including necessary formwork complete all as specified and directed. |
| 19 | M & L rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for Preparation of surface of wall and applying two coats of cement base paint with roller complete all as specified and directed. |
| 21 | Providing plain cement concrete type D-2, 1:4:8 mix (using 40 mm graded stone aggregate) as in bed to drain pipes of 300 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 22 | S & F reinforced concrete drain pipes of 300 mm dia, class NP-3, laid in trenches and jointed and tested complete all as specified and directed. Please Enable Macros to View BoQ information |