| 1 | Reinforced Cement concrete work of M-20 grade concrete with 20 mm down graded crusher broken hard granite chips |
| 2 | Column upto Lintel |
| 3 | Lintel |
| 4 | Slab for Dinning |
| 5 | Chajja (2.5'' thick) |
| 6 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing |
| 7 | Flyash brick (25x12x8)cm work in C.M. 1:6 in super structure of Ground Floor all complete |
| 8 | 16 mm thick Cement Plaster(1:6) for brick work |
| 9 | 12 mm thick Cement Plaster(1:4) for brick work |
| 10 | Painting 1 coat with approved primer to wall |
| 11 | Wall painting 2 coats with weather paint of approved shade on wall surface to give an even shade including cost of brushes and putty including cost of paint scrapping, cleaning rubbing, scaffolding etc. |
| 12 | Distempering two coats with any shade |
| 13 | Supplying, fitting and fixing vitrified tile 60x60cm colour printed 8 to 10 mm thick in floors of approved make confirming to IS : 13755 with application of polymer modified cement based water resistant adhesive bed confirming to IS : 15477 of 3mm thick bed and filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. |
| 14 | Supply, fitting & fixing of granite tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of precast tiles etc. |
| 15 | Providing and fixing UPVC Sliding Windows # Single Glazed (With MESH): Providing and fixing System Aluminum works for Sliding windows with 50mm & 35mm visible aluminum section width in the center mullion. The extruded aluminums sections should be made from Grade 6063-T5 & Anodized with Tex guard coating, silicon coated to suit marine atmosphere. All profiles should be None insulated Profiles. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. All Slider windows will be center locking. |
| 16 | Providing and fixing M.S grill of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). |
| 17 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 18 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water /moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. |
| 19 | Designing, providing, installing and fixing factory finished custom designed PEB STRUCTURE WITH LGSF SECTIONS super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The 50mm thick double skin PUF Insulated sandwich Roof Panel having core with Trapezodial Top & Micro-ribbed sheet in Bottom skin. The PUF panel shall be manufactured on continuous line running on uninterrupted power supply. Panel shall have pre coated Galvalume sheet on both side of Puf. The PPGL sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revit architecture2011 or equivalent. |
| 20 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 21 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect confirming to IRCSP63:2018 |
| 22 | Supplying and fixing of precast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984 |
| 23 | Add Cost of Internal Electrification & wiring |
| 24 | Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 25 | (Group B) |
| 26 | Group C |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class FRLS PVC conduit as required |
| 28 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (80W Light & 6A PP wiring) |
| 29 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (SB,Comp,16A PP Wiring) |
| 30 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (AC wiring) |
| 31 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 32 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 33 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 34 | 20 mm |
| 35 | 25 mm |
| 36 | Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess with phenolic laminated sheet cover including painting etc as required. |
| 37 | 75 mm X 75 mm X 60 mm deep |
| 38 | 100 mm X 100 mm X 60 mm deep |
| 39 | Supplying and fixing 3 mm stainless steel cover on the floor junction box including fabrication, with suitable stinless steel screws, etc as reqd. |
| 40 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 41 | 1-2 Module |
| 42 | 3 Module |
| 43 | 6 Module |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate, switch box etc. as required. |
| 45 | 5/6 amps switch |
| 46 | 15/16 amp switch |
| 47 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 48 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 100 cm length, or with chain hook/suspender arrangement, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 49 | Installation, testing and commissioning of ceiling fan on down rod or wall fan on the existing ceiling /surface, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. Please Enable Macros to View BoQ information Compatibility Report for BOQ_494375.xls Run on 2/3/2025 19:31 If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear truncated. 3.0 Excel 97-2003 Some cells in this workbook contain data validation rules, which refer to values on other worksheets. These rules won't be saved. 3.0 Excel 97-2003 Minor loss of fidelity Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 5.0 Excel 97-2003 |